Assessment of 300MW Turbine Generator Stator Insulation

被引:0
|
作者
Wang, Lijun [1 ]
Zhang, Yizhong [1 ]
Jin, Wenjing [1 ]
Shi, Jingzhe [1 ]
Zhou, Song [1 ]
Li, Qiang [1 ]
Liu, Song [1 ]
机构
[1] Shanghai Elect Power Generat Equipment Co Ltd, Generator Plant, Shanghai, Peoples R China
关键词
Tung oil-EMf-epoxy resin-rich insulation system; stator insulation; diagnostic test;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The 300MW turbine generator which uses Tung oil-BMI-epoxy resin-rich insulation in Wu Jing Thermal Power Plant was subjected to a wide variety of diagnostic tests during the regular planned overhaul. This generator has kept safely running for 23 years since 1991. Diagnostic tests included direct current diagnostic tests, capacitance, dissipation factor and tip-up, partial discharge, AC proof voltage test. Meanwhile, a new generator (reference generator) with the same structure was tested. The aging degradation of generator stator insulation is assessed by comparison the data of diagnostic tests for two generators. It is concluded that the aging situation of the candidate generator stator insulation is not serious and still meets the requirements of operation after safely running 23 years.
引用
收藏
页码:500 / 502
页数:3
相关论文
共 50 条
  • [1] 300MW level evaporative cooling turbine generator stator temperature field analysis
    Guo Jianhong
    Yuan Jian-hua
    Fu Deping
    Luan Ru
    Xiong Bin
    [J]. 2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 279 - +
  • [2] Assessing the flaws in welded seam of header of a 300MW steam turbine generator unit
    Song, Li
    Yang, Shuicheng
    Wei, Fengtao
    [J]. ENGINEERING PLASTICITY AND ITS APPLICATIONS FROM NANOSCALE TO MACROSCALE, PTS 1 AND 2, 2007, 340-341 : 1431 - +
  • [3] POWER PLANTS PERSONNEL TRAINING WITH 300MW GENERATOR SIMULATOR
    Lazaroiu, Gh.
    Tanttareanu, L.
    Itoafa, M.
    Alexandru, C.
    Gusti, A.
    Teaca, R.
    [J]. QUALITY MANAGEMENT IN HIGHER EDUCATION, PROCEEDINGS, 2008, : 235 - 240
  • [4] Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings
    Kim, Hee-Dong
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (01) : 280 - 285
  • [5] Experimental Research on Stator Insulation System of 5 MW Offshore Wind Turbine Generator under Simulated Marine Environments
    Liu Xuezhong
    Zhang Tianlong
    Bai Yonggang
    Ding Xiaoxia
    Wang Fangwen
    Chen Tangze
    Zhao Dan
    [J]. 2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 52 - 55
  • [6] Reconstruction of the gland sealing system of a 300MW steam turbine unit
    Xie, DM
    Liu, GL
    Wang, JM
    Yang, J
    [J]. ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 862 - 866
  • [7] Economics Analysis of Retrofit of Flow Passage of a 300MW Steam Turbine
    Shi Yang
    Li Wan-Fan
    Xie Dan-mei
    Tan Cheng-cheng
    Feng Ming
    Cai Sun
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [8] The Effect of the Marine Environment on the Stator Insulation System of an Offshore Wind Turbine Generator
    Liu, Xuezhong
    Zhang, Tianlong
    Zhang, Rui
    Bai, Yonggang
    Ding, Xiaoxia
    Zhao, Dan
    Wang, Chenxing
    Wang, Fangwen
    Chen, Tangze
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2015, 31 (03) : 10 - 17
  • [9] Condition Evaluation of Stator Winding Insulation of Vintage High Voltage Turbine Generator
    Kumar, P. G. S.
    Reddy, K. Malla
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES, 2015,
  • [10] Performance Analysis of a 300MW Turbo Generator with Different Types of Rotor Structures
    Chen, Cai
    Liu, Huijuan
    Hao, Yue
    Fu, Weinong
    [J]. 4TH INTERNATIONAL CONFERENCE ON MECHANICAL AUTOMATION AND MATERIALS ENGINEERING (ICMAME 2015), 2015, : 307 - 311