A MEMS Dielectric Affinity Glucose Biosensor

被引:13
|
作者
Huang, Xian [1 ]
Li, Siqi [2 ]
Davis, Erin [2 ]
Li, Dachao [3 ]
Wang, Qian [2 ]
Lin, Qiao [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Univ S Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
[3] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
基金
美国国家科学基金会;
关键词
Dielectric biosensor; continuous glucose monitoring; affinity detection; microelectromechanical systems technology; CONCANAVALIN-A; SENSORS; RELAXATION; VISCOSITY; CONSTANT; DEXTRAN; TISSUES; WATER; DNA;
D O I
10.1109/JMEMS.2013.2262603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Continuous glucose monitoring (CGM) sensors based on affinity detection are desirable for long-term and stable glucose management. However, most affinity sensors contain mechanical moving structures and complex design in sensor actuation and signal readout, limiting their reliability in subcutaneously implantable glucose detection. We have previously demonstrated a proof-of-concept dielectric glucose sensor that measured pre-mixed glucose-sensitive polymer solutions at various glucose concentrations. This sensor features simplicity in sensor design, and possesses high specificity and accuracy in glucose detection. However, lack of glucose diffusion passage, this device is unable to fulfill real-time in-vivo monitoring. As a major improvement to this device, we present in this paper a fully implantable MEMS dielectric affinity glucose biosensor that contains a perforated electrode embedded in a suspended diaphragm. This capacitive-based sensor contains no moving parts, and enables glucose diffusion and real-time monitoring. The experimental results indicate that this sensor can detect glucose solutions at physiological concentrations and possesses good reversibility and reliability. This sensor has a time constant to glucose concentration change at approximately 3 min, which is comparable to commercial systems. The sensor has potential applications in fully implantable CGM that require excellent long-term stability and reliability.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 50 条
  • [31] MEMS BIOSENSOR FOR POTENTIAL CANCER CELL DETECTION
    Zakaria, Nor Hisyamuddin
    Nordin, Anis Nurashikin
    Mel, Maizirwan
    Arifuzzaman, Sayeed M.
    Voiculescu, Loana
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 12, PTS A AND B, 2010, : 799 - 802
  • [32] Multiparametric MEMS Biosensor for Cell Culture Monitoring
    Liu, Fei
    Nordin, Anis Nurashikin
    Voiculescu, Ioana
    2013 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2013,
  • [33] Multiparametric MEMS Biosensor for Cell Culture Monitoring
    Liu, Fei
    Nordin, Anis Nurashikin
    Voiculescu, Ioana
    2013 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2013,
  • [34] A Review on MEMS/NEMS-Based Biosensor
    Li D.-J.
    Chen H.-Y.
    Liu C.-R.
    Fan K.
    Wang G.-F.
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2021, 49 (06): : 1228 - 1236
  • [35] MEMS biosensor for blood plasma viscosity measurements
    Cakmak, Onur
    Elbuken, Caglar
    Ermek, Erhan
    Bulut, Selma
    Kilinc, Yasin
    Baris, Ibrahim
    Kavakli, Halil
    Alaca, Erdem
    Urey, Hakan
    NEW BIOTECHNOLOGY, 2012, 29 : S162 - S163
  • [36] Piezoelectric optical MEMS scanning fluorescence biosensor
    Lo, J
    Kim, ES
    Gundersen, MA
    Marcu, L
    Advanced Biomedical and Clinical Diagnostic Systems III, 2005, 5692 : 103 - 110
  • [37] MEMS tunable dielectric resonator
    Panaitov, G.
    Ott, R.
    Klein, N.
    Nanoscale Devices - Fundamentals and Applications, 2006, 233 : 111 - 121
  • [38] Engineering and rapid selection of a low-affinity glucose/galactose-binding protein for a glucose biosensor (vol 16, pg 2350, 2007)
    Amiss, Terry J.
    Sherman, Douglas B.
    Nycz, Colleen M.
    Andaluz, Sandra A.
    Pitner, J. Bruce
    PROTEIN SCIENCE, 2007, 16 (12) : 2775 - 2775
  • [39] Intracellular glucose biosensor.
    Ye, KM
    Schultz, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U108 - U108
  • [40] Study on the biosensor for the glucose estimation
    An, Lichao
    Zeng, Heng
    Li, Xiaohui
    Niu, Hong
    Nanjing Li Gong Daxue Xuebao/Journal of Nanjing University of Science and Technology, 1994, (06): : 92 - 96