A MEMS Dielectric Affinity Glucose Biosensor

被引:13
|
作者
Huang, Xian [1 ]
Li, Siqi [2 ]
Davis, Erin [2 ]
Li, Dachao [3 ]
Wang, Qian [2 ]
Lin, Qiao [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Univ S Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
[3] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
基金
美国国家科学基金会;
关键词
Dielectric biosensor; continuous glucose monitoring; affinity detection; microelectromechanical systems technology; CONCANAVALIN-A; SENSORS; RELAXATION; VISCOSITY; CONSTANT; DEXTRAN; TISSUES; WATER; DNA;
D O I
10.1109/JMEMS.2013.2262603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Continuous glucose monitoring (CGM) sensors based on affinity detection are desirable for long-term and stable glucose management. However, most affinity sensors contain mechanical moving structures and complex design in sensor actuation and signal readout, limiting their reliability in subcutaneously implantable glucose detection. We have previously demonstrated a proof-of-concept dielectric glucose sensor that measured pre-mixed glucose-sensitive polymer solutions at various glucose concentrations. This sensor features simplicity in sensor design, and possesses high specificity and accuracy in glucose detection. However, lack of glucose diffusion passage, this device is unable to fulfill real-time in-vivo monitoring. As a major improvement to this device, we present in this paper a fully implantable MEMS dielectric affinity glucose biosensor that contains a perforated electrode embedded in a suspended diaphragm. This capacitive-based sensor contains no moving parts, and enables glucose diffusion and real-time monitoring. The experimental results indicate that this sensor can detect glucose solutions at physiological concentrations and possesses good reversibility and reliability. This sensor has a time constant to glucose concentration change at approximately 3 min, which is comparable to commercial systems. The sensor has potential applications in fully implantable CGM that require excellent long-term stability and reliability.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 50 条
  • [21] A MEMS thermal biosensor for metabolite measurements
    Wang, Li
    Lin, Qiao
    Micro-Electro-Mechanical Systems - 2005, 2005, 7 : 635 - 639
  • [22] A MEMS RF-interrogated biosensor
    Payen, S
    Walther, DC
    Pisano, AP
    2005 3RD IEEE/EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGY IN MEDICINE AND BIOLOGY, 2005, : 76 - 79
  • [23] A FLEXIBLE BIOSENSOR FOR GLUCOSE
    MITSUBAYASHI, K
    DICKS, JM
    YOKOYAMA, K
    TAKEUCHI, T
    TAMIYA, E
    KARUBE, I
    ELECTROANALYSIS, 1995, 7 (01) : 83 - 87
  • [24] Biosensor alternative: Frontal affinity chromatography
    Schriemer, DC
    ANALYTICAL CHEMISTRY, 2004, 76 (23) : 440A - 448A
  • [25] Affinity biosensor for antitumoral drugs determination
    Voinea, C.
    Ciucu, A.
    Ciucu, C.
    Voiculet, N.
    UPB Scientific Bulletin, Series B: Chemistry and Materials Science, 2002, 64 (01): : 29 - 38
  • [26] A piezoelectric biosensor as a direct affinity sensor
    Minunni, M
    Mascini, M
    OPTICAL SENSORS AND MICROSYSTEMS: NEW CONCEPTS, MATERIALS, TECHNOLOGIES, 2000, : 143 - 150
  • [27] A dielectric affinity microbiosensor
    Huang, Xian
    Li, Siqi
    Schultz, Jerome S.
    Wang, Qian
    Lin, Qiao
    APPLIED PHYSICS LETTERS, 2010, 96 (03)
  • [28] Dielectric film for biosensor application
    Fang, X. Y.
    Tan, O. K.
    Wei, Q.
    Yao, M. W.
    Tjin, S. C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (01) : 78 - 83
  • [29] A MEMS thermal biosensor for metabolic monitoring applications
    Wang, Li
    Sipe, David M.
    Xu, Yong
    Lin, Qiao
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2008, 17 (02) : 318 - 327
  • [30] Piezoelectric Biosensor based on ultrasensitive MEMS system
    He, Ji-Huan
    He, Chun-Hui
    Qian, Man-Yu
    Alsolami, Abdulrahman Ali
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 376