Impact of electrode tip shape on catheter performance in cardiac radiofrequency ablation

被引:4
|
作者
Petras, Argyrios [1 ]
Moreno Weidmann, Zoraida [2 ]
Echeverria Ferrero, Marina [3 ]
Leoni, Massimiliano
Guerra, Jose M. [2 ]
Gerardo-Giorda, Luca [1 ,4 ]
机构
[1] Austrian Acad Sci, RICAM, Linz, Austria
[2] Univ Autonoma Barcelona, Hosp Santa Creu & St Pau, Dept Cardiol, IIB ST PAU,CIBERCV, Barcelona, Spain
[3] BCAM Basque Ctr Appl Math, Bilbao, Spain
[4] Johannes Kepler Univ Linz, Inst Math Methods Med & Data Based Modelling, Linz, Austria
来源
HEART RHYTHM O2 | 2022年 / 3卷 / 06期
关键词
Cardiac ablation; Computational modeling and simulation; Electrode tip; Lesion science; Open irrigation; Radiofrequency; Steam pop; CONTACT FORCE; LESION SIZE; TEMPERATURE;
D O I
10.1016/j.hroo.2022.07.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The role of catheter tip shape on the safety and efficacy of radiofrequency (RF) ablation has been overlooked, although differences have been observed in clinical and research fields. OBJECTIVE The purpose of this study was to analyze the role of electrode tip shape in RF ablation using a computational model. METHODS We simulated 108 RF ablations through a realistic 3-dimensional computational model considering 2 clinically used, open-irrigated catheters (spherical and cylindrical tip), varying contact force (CF), blood flow, and irrigation. Lesions are defined by the 50 degrees C isotherm contour and evaluated by means of width, depth, depth at maximum width, and volume. Ablations are deemed as safe, critical (tissue temperature.90 degrees C), and pop (tissue temperature.100 degrees C). RESULTS Tissue-electrode contact is less for the spherical tip at low CF but the relationship is inverted at high CF. At low CF, the cylindrical tip generates deeper and wider lesions and a 4-fold larger volume. With increasing CF, the lesions generated by the spherical tip become comparable to those generated by the cylindrical tip. The 2 tips feature different safety profiles: CF and power are the main determinants of pops for the spherical tip; power is the main factor for the cylindrical tip; and CF has a marginal effect. The cylindrical tip is more prone to pop generation at higher powers. Saline irrigation and blood flow effect do not depend on tip shape. CONCLUSION Tip shape determines the performance of ablation catheters and has a major impact on their safety profile. The cylindrical tip shows more predictable behavior in a wide range of CF values.
引用
收藏
页码:699 / 705
页数:7
相关论文
共 50 条
  • [21] Clinical review of radiofrequency catheter ablation for cardiac arrhythmias
    Yee, R
    Connolly, S
    Noorani, H
    CANADIAN JOURNAL OF CARDIOLOGY, 2003, 19 (11) : 1273 - 1284
  • [22] TEMPERATURE GUIDED RADIOFREQUENCY CATHETER ABLATION - CATHETER TIP TEMPERATURE UNDERESTIMATES TISSUE TEMPERATURE
    KONGSGAARD, E
    STEEN, T
    AMLIE, JP
    CIRCULATION, 1994, 90 (04) : 271 - 271
  • [23] MANAGEMENT OF CARDIAC-ARRHYTHMIAS WITH RADIOFREQUENCY CATHETER ABLATION
    WAGSHAL, AB
    PIRES, LA
    HUANG, SKS
    ARCHIVES OF INTERNAL MEDICINE, 1995, 155 (02) : 137 - 147
  • [24] Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation
    Pilcher, Thomas A.
    Sanford, Anna L.
    Saul, J. Philip
    Haemmerich, Dieter
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (12): : 1368 - 1374
  • [25] Radiofrequency ablation with a vibrating catheter: A new method for electrode cooling
    Yu, Kaihong
    Yamashita, Tetsui
    Shingyochi, Shigeaki
    Matsumoto, Kazuo
    Ohta, Makoto
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (05) : 458 - 467
  • [26] Biophysics and clinical utility of irrigated-tip radiofrequency catheter ablation
    Houmsse, Mahmoud
    Daoud, Emile G.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (01) : 59 - 70
  • [27] ELECTRODE TEMPERATURES DURING RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY PATHWAYS
    CALKINS, HG
    PRYSTOWSKY, EN
    YOUNG, P
    TOMASELLI, GF
    LAWRENCE, JH
    CARLSON, MD
    KLEIN, LS
    CIRCULATION, 1993, 88 (04) : 164 - 164
  • [28] Radiofrequency catheter ablation of ventricular tachycardia caused by the tip of a defibrillation lead
    Bulava, Alan
    Eisenberger, Martin
    Hanis, Jiri
    EUROPACE, 2015, 17 (07): : 1091 - 1091
  • [29] Radiofrequency tissue ablation: Importance of local temperature along the electrode tip exposure in determining lesion shape and size
    Goldberg, SN
    Gazelle, GS
    Halpern, EF
    Rittman, WJ
    Mueller, PR
    Rosenthal, DI
    ACADEMIC RADIOLOGY, 1996, 3 (03) : 212 - 218
  • [30] Radiofrequency ablation using a needle electrode inserted into muscle: Effect of a small gap between the catheter tip and muscle surface
    Yokoyama, K
    Nakagawa, H
    Zei, PC
    Stevenson, WG
    Mest, R
    Lee, J
    Rordorf, R
    Lazzara, R
    Jackman, WM
    CIRCULATION, 2005, 112 (17) : U638 - U639