Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation

被引:18
|
作者
Pilcher, Thomas A.
Sanford, Anna L.
Saul, J. Philip
Haemmerich, Dieter
机构
[1] Med Univ S Carolina, Div Pediat Cardiol, Charleston, SC 29425 USA
[2] Clemson Univ, Dept Bioengn, Clemson, SC USA
来源
关键词
ablation; convective cooling; lesion size; large-tip catheter; cooled-tip catheter;
D O I
10.1111/j.1540-8159.2006.00549.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. Methods. Porcine hearts were sectioned into 72 pieces and placed in a temperature-con trolled saline both (37 degrees C) with varying directed flow rates (0, 1, 2, and 3 L/min). Cooled-tip RF ablation (4 mm tip) was performed for 1 minute on 36 tissue sections with power manually titrated to keep tip temperature below 40 degrees C. Large-tip catheter ablation (10 mm tip) was performed at 65 degrees C target temperature for 1 minute on 36 tissue sections. For each catheter, flow rates were randomized between applications. The tissue pieces were sectioned and measured to determine lesion depth, width, and volume. Results. Lesion dimensions were independent of the flow rate for the cooled-tip catheter (mean volumes: 382.0 +/- 121.6, 419.9 +/- 133.4, 375.9 +/- 169.1, and 346.7 +/- 173.4 mm(3) for 0, 1, 2, and 3 L/min flow rate, respectively, P = 0.78). For the large-tip catheter, lesion size varied significantly with flow, such that higher flow rates produced larger lesions (mean volumes: 120.7 +/- 50.7, 256.5 +/- 97.9, 393.4 +/- 149.9, and 548.9 +/- 157.0 mm(3) for 0, 1, 2, and 3 L/min flow rate respectively, P < 0.001) Conclusion. During RF ablation, blood flow rate significantly affects lesion size for large-tip but not cooled-tip catheters. At low flow rates (0-1 L/min) cooled-tip catheters create larger lesions, while at high flow rates (3 L/min) large-tip catheters create larger lesions.
引用
收藏
页码:1368 / 1374
页数:7
相关论文
共 50 条
  • [1] Catheter ablation of atrial flutter: Do outcomes of catheter ablation with "large-tip" versus "cooled-tip" catheters really differ? Editorial comment
    Calkins, H
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (10) : 1131 - 1132
  • [2] TYPICAL ATRIAL FLUTTER: RADIOFREQUENCY CATHETER ABLATION OF CAVOTRICUSPID ISTHMUS WITH COOLED-TIP CATHETER
    Femenia, Francisco J.
    Penafort, Fernando
    Arce, Mauricio
    Arrieta, Martin
    Gutierrez, Daniel
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2009, 38 (01): : 21 - 26
  • [3] Cooled-tip diode laser catheter for improved catheter ablation of ventricular tachycardia
    Snakard, EP
    Miller, M
    Berridge, B
    Gowda, A
    McNichols, RJ
    Fossum, T
    JOURNAL OF INVESTIGATIVE SURGERY, 2001, 14 (06) : 357 - 366
  • [4] Linear Catheter Ablation of the Right Atrium for Rapid Atrial Pacing-Induced Sustained Atrial Fibrillation in Dogs Comparison of Large-Tip, Coil-Tip, and Cooled-Tip Catheter Ablations
    Watanabe, Ichiro
    Okumura, Yasuo
    Kogawa, Rikitake
    Sasaki, Naoko
    Ohkubo, Kimie
    Kofune, Masayoshi
    Nagashima, Koichi
    Sonoda, Kazumasa
    Mano, Hiroaki
    Hirayama, Atsushi
    INTERNATIONAL HEART JOURNAL, 2012, 53 (06) : 375 - 382
  • [5] Catheter ablation of ventricular epicardial tissue - A comparison of standard and cooled-tip radiofrequency energy
    d'Avila, A
    Houghtaling, C
    Gutierrez, P
    Vragovic, O
    Ruskin, JN
    Josephson, ME
    Reddy, VY
    CIRCULATION, 2004, 109 (19) : 2363 - 2369
  • [6] CATHETER ABLATION OF ATRIOVENTRICULAR JUNCTION USING RADIOFREQUENCY CURRENT IN 17 PATIENTS - COMPARISON OF STANDARD AND LARGE-TIP CATHETER ELECTRODES
    JACKMAN, WM
    WANG, XZ
    FRIDAY, KJ
    FITZGERALD, DM
    ROMAN, C
    MOULTON, K
    MARGOLIS, PD
    BOWMAN, AJ
    KUCK, KH
    NACCARELLI, GV
    PITHA, JV
    DYER, J
    LAZZARA, R
    CIRCULATION, 1991, 83 (05) : 1562 - 1576
  • [7] A prospective randomised comparison of large-tip cryoablation and 8-mm-tip radiofrequency catheter ablation of atrial flutter
    Helena Malmborg
    Stefan Lönnerholm
    Carina Blomström Lundqvist
    Journal of Interventional Cardiac Electrophysiology, 2009, 24 : 127 - 131
  • [8] A prospective randomised comparison of large-tip cryoablation and 8-mm-tip radiofrequency catheter ablation of atrial flutter
    Malmborg, Helena
    Lonnerholm, Stefan
    Lundqvist, Carina Blomstrom
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2009, 24 (02) : 127 - 131
  • [9] Discrepancies between catheter tip and tissue temperature in cooled-tip ablation - Relevance to guiding left atrial ablation
    Bruce, GK
    Bunch, TJ
    Milton, MA
    Sarabanda, A
    Johnson, SB
    Packer, DL
    CIRCULATION, 2005, 112 (07) : 954 - 960
  • [10] Radiofrequency Catheter Selection Based on Cavotricuspid Angiography Compared with a Control Group with an Externally Cooled-Tip Catheter: A Randomized Pilot Study
    Da Costa, Antoine
    Romeyer-Bouchard, Cecile
    Jamon, Yann
    Bisch, Laurence
    Isaaz, Karl
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (05) : 492 - 498