Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation

被引:18
|
作者
Pilcher, Thomas A.
Sanford, Anna L.
Saul, J. Philip
Haemmerich, Dieter
机构
[1] Med Univ S Carolina, Div Pediat Cardiol, Charleston, SC 29425 USA
[2] Clemson Univ, Dept Bioengn, Clemson, SC USA
来源
关键词
ablation; convective cooling; lesion size; large-tip catheter; cooled-tip catheter;
D O I
10.1111/j.1540-8159.2006.00549.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. Methods. Porcine hearts were sectioned into 72 pieces and placed in a temperature-con trolled saline both (37 degrees C) with varying directed flow rates (0, 1, 2, and 3 L/min). Cooled-tip RF ablation (4 mm tip) was performed for 1 minute on 36 tissue sections with power manually titrated to keep tip temperature below 40 degrees C. Large-tip catheter ablation (10 mm tip) was performed at 65 degrees C target temperature for 1 minute on 36 tissue sections. For each catheter, flow rates were randomized between applications. The tissue pieces were sectioned and measured to determine lesion depth, width, and volume. Results. Lesion dimensions were independent of the flow rate for the cooled-tip catheter (mean volumes: 382.0 +/- 121.6, 419.9 +/- 133.4, 375.9 +/- 169.1, and 346.7 +/- 173.4 mm(3) for 0, 1, 2, and 3 L/min flow rate, respectively, P = 0.78). For the large-tip catheter, lesion size varied significantly with flow, such that higher flow rates produced larger lesions (mean volumes: 120.7 +/- 50.7, 256.5 +/- 97.9, 393.4 +/- 149.9, and 548.9 +/- 157.0 mm(3) for 0, 1, 2, and 3 L/min flow rate respectively, P < 0.001) Conclusion. During RF ablation, blood flow rate significantly affects lesion size for large-tip but not cooled-tip catheters. At low flow rates (0-1 L/min) cooled-tip catheters create larger lesions, while at high flow rates (3 L/min) large-tip catheters create larger lesions.
引用
收藏
页码:1368 / 1374
页数:7
相关论文
共 50 条
  • [31] TEMPERATURE GUIDED RADIOFREQUENCY CATHETER ABLATION - CATHETER TIP TEMPERATURE UNDERESTIMATES TISSUE TEMPERATURE
    KONGSGAARD, E
    STEEN, T
    AMLIE, JP
    CIRCULATION, 1994, 90 (04) : 271 - 271
  • [32] Cooled needle catheter ablation creates deeper and wider lesions than irrigated tip catheter ablation
    Thiagalingam, A
    Pouliopoulos, J
    Barry, MA
    Boyd, AC
    Eipper, V
    Yung, T
    Ross, DL
    Kovoor, P
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (05) : 508 - 515
  • [33] Cooled intramural needle catheter ablation creates deeper lesions than irrigated tip catheter ablation
    Thiagalingam, A
    Campbell, CR
    Boyd, AC
    Eipper, VE
    Ross, DL
    Kovoor, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (07): : 965 - 970
  • [34] Efficacy and safety of intraoperative cooled-tip radiofrequency ablation to treat permanent atrial fibrillation
    Deneke, T
    Khargi, K
    Grewe, PH
    Kuschkowitz, F
    Lawo, T
    Calcum, B
    Muegge, A
    Laczkovics, A
    Lemke, B
    CIRCULATION, 2003, 108 (17) : 707 - 707
  • [35] Impact of irrigation flow rate and intrapericardial fluid on cooled-tip epicardial radiofrequency ablation
    Aryana, Arash
    O'Neill, Padraig Gearoid
    Pujara, Deep K.
    Singh, Steve K.
    Bowers, Mark R.
    Allen, Shelley L.
    d'Avila, Andre
    HEART RHYTHM, 2016, 13 (08) : 1602 - 1611
  • [36] Finite element modeling of cooled-tip probe radiofrequency ablation processes in liver tissue
    Barauskas, Rimantas
    Gulbinas, Antanas
    Vanagas, Tomas
    Barauskas, Giedrius
    COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (06) : 694 - 708
  • [37] Catheter intramural needle radiofrequency ablation creates deeper lesions than irrigated tip catheter ablation
    Thiagalingam, A
    Campbell, CR
    Boyd, A
    Ross, DL
    Kovoor, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (11): : 2146 - 2150
  • [38] Intraoperative cooled-tip radiofrequency linear atrial ablation to treat permanent atrial fibrillation
    Deneke, Thomas
    Khargi, Krishna
    Grewe, Peter H.
    Lawo, Thomas
    Laczkovics, Axel
    Calcum, Bernd
    Muegge, Andreas
    Lemke, Bernd
    Fritz, Markus
    CIRCULATION, 2006, 114 (18) : 752 - 752
  • [39] Intraciperative cooled-tip radiofrequency linear atrial ablation to treat permanent atrial fibrillation
    Deneke, T
    Khargi, K
    Grewe, PH
    Lawo, T
    Mügge, A
    Laczkovics, A
    Lemke, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 30A - 30A
  • [40] Intraoperative cooled-tip radiofrequency linear atrial ablation to treat permanent atrial fibrillation
    Deneke, T.
    Khargi, K.
    Fritz, M.
    Lawo, T.
    Muegge, A.
    Laczkovics, A.
    Calcum, B.
    Lemke, B.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (01) : 128 - 128