Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation

被引:18
|
作者
Pilcher, Thomas A.
Sanford, Anna L.
Saul, J. Philip
Haemmerich, Dieter
机构
[1] Med Univ S Carolina, Div Pediat Cardiol, Charleston, SC 29425 USA
[2] Clemson Univ, Dept Bioengn, Clemson, SC USA
来源
关键词
ablation; convective cooling; lesion size; large-tip catheter; cooled-tip catheter;
D O I
10.1111/j.1540-8159.2006.00549.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. Methods. Porcine hearts were sectioned into 72 pieces and placed in a temperature-con trolled saline both (37 degrees C) with varying directed flow rates (0, 1, 2, and 3 L/min). Cooled-tip RF ablation (4 mm tip) was performed for 1 minute on 36 tissue sections with power manually titrated to keep tip temperature below 40 degrees C. Large-tip catheter ablation (10 mm tip) was performed at 65 degrees C target temperature for 1 minute on 36 tissue sections. For each catheter, flow rates were randomized between applications. The tissue pieces were sectioned and measured to determine lesion depth, width, and volume. Results. Lesion dimensions were independent of the flow rate for the cooled-tip catheter (mean volumes: 382.0 +/- 121.6, 419.9 +/- 133.4, 375.9 +/- 169.1, and 346.7 +/- 173.4 mm(3) for 0, 1, 2, and 3 L/min flow rate, respectively, P = 0.78). For the large-tip catheter, lesion size varied significantly with flow, such that higher flow rates produced larger lesions (mean volumes: 120.7 +/- 50.7, 256.5 +/- 97.9, 393.4 +/- 149.9, and 548.9 +/- 157.0 mm(3) for 0, 1, 2, and 3 L/min flow rate respectively, P < 0.001) Conclusion. During RF ablation, blood flow rate significantly affects lesion size for large-tip but not cooled-tip catheters. At low flow rates (0-1 L/min) cooled-tip catheters create larger lesions, while at high flow rates (3 L/min) large-tip catheters create larger lesions.
引用
收藏
页码:1368 / 1374
页数:7
相关论文
共 50 条
  • [41] Radiofrequency ablation of VX2 kidney tumor in rabbits with cooled-tip electrode
    Lee, J
    Kim, S
    Kim, C
    RADIOLOGY, 2001, 221 : 260 - 261
  • [42] Left Ventricular Perforation During Cooled-Tip Radiofrequency Ablation for Ischemic Ventricular Tachycardia
    Jimenez, Alejandro
    Kuk, Richard
    Ahmad, Ghada
    Tian, Jing
    Garcia, Jose
    Saliaris, Anastasios
    Shorofksy, Stephen
    Dickfeld, Timm
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (01): : 115 - 116
  • [43] Utility of tip thermometry during radiofrequency ablation in humans using an internally perfused saline cooled catheter
    Wharton, JM
    Wilber, DJ
    Calkins, H
    Epstein, AE
    Ellenbogen, KA
    Carlson, MD
    Stevenson, WG
    Packer, DL
    Hummel, J
    Stark, S
    Kopelman, H
    Tohou, PJ
    CIRCULATION, 1997, 96 (08) : 1775 - 1775
  • [44] Radiofrequency catheter-tip temperature in
    Rothman, SA
    Cossu, SF
    Hsia, HH
    Chmielewski, L
    Buxton, AE
    Miller, JM
    CIRCULATION, 1996, 94 (08) : 2894 - 2894
  • [45] Epicardial ablation with cooled tip catheter close to the coronary arteries is effective and
    Kawamura, M.
    Kobayashi, Y.
    Tanno, K.
    EUROPEAN HEART JOURNAL, 2007, 28 : 158 - 158
  • [46] Temperature guided radiofrequency catheter ablation of myocardium: Comparison of catheter tip and tissue temperatures in vitro
    Kongsgaard, E
    Steen, T
    Jensen, O
    Aass, H
    Amlie, JP
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (05): : 1252 - 1260
  • [47] A comparison of microbubble formation during radiofrequency ablation at the orifice of pulmonary veins using an 8-mm versus a closed-loop, cooled-tip catheter
    Bunch, TJ
    Bruce, GK
    Johnson, SB
    Sarabanda, A
    Milton, MA
    Packer, DL
    CIRCULATION, 2004, 110 (17) : 543 - 543
  • [48] Radiofrequency Ablation for Eradication of Renal Tumor in a Rabbit Model by Using a Cooled-tip Electrode Technique
    Yi Miao
    Yicheng Ni
    Hilde Bosmans
    Jie Yu
    Johan Vaninbroukx
    Steven Dymarkowski
    Hao Zhang
    Guy Marchal
    Annals of Surgical Oncology, 2001, 8 (8) : 651 - 657
  • [49] Radiofrequency catheter ablation of ventricular tachycardia caused by the tip of a defibrillation lead
    Bulava, Alan
    Eisenberger, Martin
    Hanis, Jiri
    EUROPACE, 2015, 17 (07): : 1091 - 1091
  • [50] Impact of electrode tip shape on catheter performance in cardiac radiofrequency ablation
    Petras, Argyrios
    Moreno Weidmann, Zoraida
    Echeverria Ferrero, Marina
    Leoni, Massimiliano
    Guerra, Jose M.
    Gerardo-Giorda, Luca
    HEART RHYTHM O2, 2022, 3 (06): : 699 - 705