DEVELOPMENT AND VALIDATION OF THE REALISTIC ANTHROPOMORPHIC FLEXIBLE (RAF) PHANTOM

被引:10
|
作者
Lombardo, Pasquale A. [1 ,2 ]
Vanhavere, Filip [3 ]
Lebacq, Anne L. [4 ]
Struelens, Lara [1 ]
Bogaerts, Ria [2 ]
机构
[1] SCK CEN, Res Dosimetr Applicat, Boeretang 200, B-2400 Mol, Belgium
[2] Katholieke Univ Leuven, Lab Expt Radiotherapy, Herestr 49, B-3000 Leuven, Belgium
[3] SCK CEN, Radiat Protect Dosimetry & Calibrat, Boeretang 200, B-2400 Mol, Belgium
[4] SCK CEN, Dosimetr & Calibrat Serv, Boeretang 200, B-2400 Mol, Belgium
来源
HEALTH PHYSICS | 2018年 / 114卷 / 05期
关键词
Dose; organ; dose; skin; Monte Carlo; radiation dose; COMPUTATIONAL PHANTOMS; PROTECTION; CONVERSION; DOSIMETRY; MODELS;
D O I
10.1097/HP.0000000000000805
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Voxel phantoms developed by segmenting computed tomography images are known to be more anatomically accurate than mathematical phantoms. However, due to their lack of flexibility and the complexity of voxel datasets, the use of voxel phantoms in dosimetry is often impractical. This paper describes the development of the realistic anthropomorphic flexible (RAF) polygonal mesh phantom, a novel phantom based on Boundary Representation (B-Rep) that merges anatomical accuracy and flexibility. Rather than using segmentation of tomography images, the modeling of the phantom's organs was based on freely and commercially available anatomical atlases, ICRP 89, and recent medical literature. To validate the phantom, a high-resolution voxel version was created for the MCNPx transport code. The voxelized RAF phantom was validated by comparing it with the ICRP 110 male phantom for external irradiations with parallel beams of photons and electrons. Dose coefficients obtained from simulations with the RAF phantom were compared with those from ICRP Publication 116. Relevant differences in organ doses were found.
引用
收藏
页码:486 / 499
页数:14
相关论文
共 50 条
  • [31] USES OF AN ANTHROPOMORPHIC CHEST PHANTOM
    GILLAN, GD
    PEARCE, JG
    ROECK, WW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (01) : 204 - 204
  • [32] Design, development and characterization of the third-generation CTN anthropomorphic oncology phantom for PET and SPECT quantitative validation and testing
    Sunderland, John
    Muzic, Raymond
    Lodge, Martin
    Christian, Paul
    Hoffman, John
    Bradshaw, Tyler
    Kulkarni, Aishwarya
    Gallo, Sven
    Uribe, Carlos
    Wojtylak, Patrick
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [33] IMPROVED CARDIAC ANTHROPOMORPHIC PHANTOM
    SMITH, SW
    COMBS, MP
    ADAMS, DB
    KISSLO, JA
    JOURNAL OF ULTRASOUND IN MEDICINE, 1994, 13 (08) : 601 - 625
  • [34] Prostate dosimetry in an anthropomorphic phantom
    Yu P.K.N.
    Cheung T.
    Butson M.J.
    Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (2): : 60 - 62
  • [35] ANTHROPOMORPHIC CARDIAC ULTRASOUND PHANTOM
    SMITH, SW
    RINALDI, JE
    IEEE 1989 ULTRASONICS SYMPOSIUM : PROCEEDINGS, VOLS 1 AND 2, 1989, : 931 - 934
  • [36] ANTHROPOMORPHIC CARDIAC ULTRASOUND PHANTOM
    SMITH, SW
    RINALDI, JE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (10) : 1055 - 1058
  • [37] THE USE OF AN ANTHROPOMORPHIC ULTRASOUND PHANTOM
    DYE, REA
    BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (642): : 542 - 543
  • [38] VERSATILE VARIABLE ANTHROPOMORPHIC PHANTOM
    OXBY, CB
    BROOKS, K
    PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (02): : 440 - 442
  • [39] A 3D Printing-based Realistic Anthropomorphic Dental Phantom and its imaging Evaluation
    Lee, Do Il
    Yang, Zepa
    Kim, Jong Hyo
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [40] A computer-controlled pump and realistic, anthropomorphic respiratory phantom for validating image-guided systems
    Lin, Ralph
    Wilson, Emmanuel
    Tang, Jonathan
    Stoianovici, Dan
    Cleary, Kevin
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509