DEVELOPMENT AND VALIDATION OF THE REALISTIC ANTHROPOMORPHIC FLEXIBLE (RAF) PHANTOM

被引:10
|
作者
Lombardo, Pasquale A. [1 ,2 ]
Vanhavere, Filip [3 ]
Lebacq, Anne L. [4 ]
Struelens, Lara [1 ]
Bogaerts, Ria [2 ]
机构
[1] SCK CEN, Res Dosimetr Applicat, Boeretang 200, B-2400 Mol, Belgium
[2] Katholieke Univ Leuven, Lab Expt Radiotherapy, Herestr 49, B-3000 Leuven, Belgium
[3] SCK CEN, Radiat Protect Dosimetry & Calibrat, Boeretang 200, B-2400 Mol, Belgium
[4] SCK CEN, Dosimetr & Calibrat Serv, Boeretang 200, B-2400 Mol, Belgium
来源
HEALTH PHYSICS | 2018年 / 114卷 / 05期
关键词
Dose; organ; dose; skin; Monte Carlo; radiation dose; COMPUTATIONAL PHANTOMS; PROTECTION; CONVERSION; DOSIMETRY; MODELS;
D O I
10.1097/HP.0000000000000805
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Voxel phantoms developed by segmenting computed tomography images are known to be more anatomically accurate than mathematical phantoms. However, due to their lack of flexibility and the complexity of voxel datasets, the use of voxel phantoms in dosimetry is often impractical. This paper describes the development of the realistic anthropomorphic flexible (RAF) polygonal mesh phantom, a novel phantom based on Boundary Representation (B-Rep) that merges anatomical accuracy and flexibility. Rather than using segmentation of tomography images, the modeling of the phantom's organs was based on freely and commercially available anatomical atlases, ICRP 89, and recent medical literature. To validate the phantom, a high-resolution voxel version was created for the MCNPx transport code. The voxelized RAF phantom was validated by comparing it with the ICRP 110 male phantom for external irradiations with parallel beams of photons and electrons. Dose coefficients obtained from simulations with the RAF phantom were compared with those from ICRP Publication 116. Relevant differences in organ doses were found.
引用
收藏
页码:486 / 499
页数:14
相关论文
共 50 条
  • [21] Clinical Validation of Proton Pencil Beam Scanning on an Anthropomorphic Lung Phantom
    Wang, P.
    Tang, S.
    Cummings, D.
    Lee, A. K.
    Chang, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E736 - E736
  • [22] Additively Manufactured Patient-Specific Anthropomorphic Thorax Phantom With Realistic Radiation Attenuation Properties
    Hatamikia, Sepideh
    Oberoi, Gunpreet
    Unger, Ewald
    Kronreif, Gernot
    Kettenbach, Joachim
    Buschmann, Martin
    Figl, Michael
    Knaeusl, Barbara
    Moscato, Francesco
    Birkfellner, Wolfgang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [23] First Acquisitions of Realistic Proton Therapy Treatments Delivered on an Anthropomorphic Phantom with a Prompt Gamma Camera
    Perali, I.
    Janssens, G.
    Bombelli, L.
    Clementel, E.
    Fiorini, C.
    Hotoiu, L.
    Peloso, R.
    Prieels, D.
    Smeets, J.
    Sterpin, E.
    Vander Stappen, F.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [24] Development of an Anthropomorphic Phantom of the Axillary Region for Microwave Imaging Assessment
    Savazzi, Matteo
    Abedi, Soroush
    Istuk, Niko
    Joachimowicz, Nadine
    Roussel, Helene
    Porter, Emily
    O'Halloran, Martin
    Costa, Jorge R.
    Fernandes, Carlos A.
    Felicio, Joao M.
    Conceicao, Raquel C.
    SENSORS, 2020, 20 (17) : 1 - 20
  • [25] Development and application of anthropomorphic voxel phantom of the head for in vivo measurement
    Vrba, T.
    RADIATION PROTECTION DOSIMETRY, 2007, 127 (1-4) : 201 - 204
  • [26] Development of a physical 3D anthropomorphic breast phantom
    Carton, Ann-Katherine
    Bakic, Predrag
    Ullberg, Christer
    Derand, Helen
    Maidment, Andrew D. A.
    MEDICAL PHYSICS, 2011, 38 (02) : 891 - 896
  • [27] Validation of a Novel Vector Method for Blood Peak Velocity Detection in an Anthropomorphic Phantom
    Matera, R.
    Ricci, S.
    Yu, A. C. H.
    Yiu, B. Y. S.
    Tortoli, P.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [28] Validation of spine SBRT using a 3D printed Anthropomorphic phantom
    Dekker, K. H.
    Alexander, K. M.
    de Moraes, F. Ynoe
    Olding, T.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [29] Anthropomorphic Development for Intermodality Deformation Algorithms Validation
    Vincent, S. D.
    Archambault, L.
    MEDICAL PHYSICS, 2012, 39 (06) : 3672 - 3672
  • [30] AN ANTHROPOMORPHIC PHANTOM FOR PERIODONTAL RADIOGRAPHY
    VISSER, H
    HERMANN, KP
    PFEIFFER, T
    UMLAUF, J
    KRUGER, W
    HARDER, D
    DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (03) : 195 - 197