A computer-controlled pump and realistic, anthropomorphic respiratory phantom for validating image-guided systems

被引:2
|
作者
Lin, Ralph [1 ]
Wilson, Emmanuel [1 ]
Tang, Jonathan [1 ]
Stoianovici, Dan [2 ]
Cleary, Kevin [1 ]
机构
[1] Georgetown Univ, Med Ctr, Imaging Sci & Informat Syst Ctr, Dept Radiol, Washington, DC 20007 USA
[2] Johns Hopkins Med, Brady Urol Inst, URobot Lab, Baltimore, MD USA
关键词
abdominal procedures; image-guided therapy; medical robotics; surgical simulation; respiratory motion; validation;
D O I
10.1117/12.712226
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of image-guided interventions requires validation studies to evaluate new protocols. So far, these validation studies have been limited to animal models and to software and physical phantoms that simulate respiratory motion but cannot accommodate needle punctures in a realistic manner. We have built a computer-controlled pump that drives an anthropomorphic respiratory phantom for simulating natural breathing patterns. This pump consists of a power supply, a motion controller with servo amplifier, linear actuator, and custom fabricated pump assembly. By generating several sample waveforms, we were able to simulate typical breathing patterns. Using this pump, we were able to produce chest wall movements similar to typical chest wall movements observed in humans. This system has potential applications for evaluating new respiratory compensation algorithms and may facilitate improved testing of image-guided protocols under realistic interventional conditions.
引用
收藏
页数:9
相关论文
共 27 条
  • [1] Validating computer-controlled analytical systems for pharmaceutical laboratories
    Huber, L
    Thomas, M
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1995, 13 (06): : 466 - &
  • [2] Respiratory liver motion simulator for validating image-guided systems ex-vivo
    L. Maier-Hein
    F. Pianka
    S. A. Müller
    U. Rietdorf
    A. Seitel
    A. M. Franz
    I. Wolf
    B. M. Schmied
    H.-P. Meinzer
    International Journal of Computer Assisted Radiology and Surgery, 2008, 2 : 287 - 292
  • [3] Respiratory liver motion simulator for validating image-guided systems ex-vivo
    Maier-Hein, L.
    Pianka, F.
    Mueller, S. A.
    Rietdorf, U.
    Seitel, A.
    Franz, A. M.
    Wolf, I.
    Schmied, B. M.
    Meinzer, H. -P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 2 (05) : 287 - 292
  • [4] Development of a computer-controlled phantom to simulate tumor motions applied to image guided adaptive radiotherapy
    Lo, D
    Vo, V
    Jiang, S
    Tseng, H
    Sharp, G
    Neicu, T
    Weinberg, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1846 - 1846
  • [5] Anthropomorphic liver phantom with flow for multimodal image-guided liver therapy research and training
    Rethy, Anna
    Saeternes, Jorn Ove
    Halgunset, Jostein
    Marvik, Ronald
    Hofstad, Erlend F.
    Sanchez-Margallo, Juan A.
    Lango, Thomas
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (01) : 61 - 72
  • [6] Anthropomorphic liver phantom with flow for multimodal image-guided liver therapy research and training
    Anna Rethy
    Jørn Ove Sæternes
    Jostein Halgunset
    Ronald Mårvik
    Erlend F. Hofstad
    Juan A. Sánchez-Margallo
    Thomas Langø
    International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 61 - 72
  • [7] Hydrodynamic Gene Delivery to Swine Skeletal Muscle Using Image-Guided, Computer-Controlled Injection System
    Kamimura, Kenya
    Suda, Takeshi
    Zhang, Guisheng
    Liu, Dexi
    MOLECULAR THERAPY, 2009, 17 : S305 - S305
  • [8] Image-guided Application and Monitoring of Transcranial Focused Ultrasound in Realistic Human Head Phantom
    O'Brien, P. D.
    Smith, Collin S.
    Ebbini, Emad S.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1898 - 1901
  • [9] A Computer-Controlled Dynamic Phantom for Respiratory-Gated Medical Radiotherapy Research
    Bandala, Manuel
    Joyce, Malcolm J.
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2013, E96A (07) : 1609 - 1616
  • [10] Developing a Pneumatic-Driven, Dual-Modal (MR/CT) and Anthropomorphic Breathing Phantom for Image-Guided Radiotherapy
    Chiu, T.
    Ho, S.
    Visak, J.
    Willis, M.
    Zhang, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E513 - E513