Control of a mock circulatory system to simulate the short-term baroreflex

被引:4
|
作者
Mushi, Simon [1 ]
Yu, Yih-Choung [2 ]
机构
[1] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA 22903 USA
[2] Lafayette Coll, Dept Elect & Comp Engn, Easton, PA 18042 USA
关键词
D O I
10.1109/ACC.2008.4586598
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A mock circulatory system (MCS) integrated with the baroreceptor reflex, a neurological function that regulates the mean systemic arterial pressure (P-sa) by adjusting heart rate, ventricular contractility, and systemic resistance through negative feedback, was developed to simulate the key hemodynamic variables in response to various physiological load changes. The MCS consists of two compliance chambers representing the left atrium and systemic artery, a proportional valve as a variable resistor mimicking the systemic vascular resistance (SVR), and a centrifugal pump as a current source simulating the pumping mechanism of the heart. The model of the baroreceptor reflex was implemented in software to generate the reference signals of the cardiac output (CO) and SVR. These two reference signals along with the models of the centrifugal pump and the proportional valve were used to control the rotational speed of the pump and the gap of the valve such that the desired CO and SVR can be reached. Performance of the MCS was under different cardiovascular demand levels from resting c, Atar y exercise. The test results show that this simple MCS was able to simulate the response of key hemodynamic variables comparable to the same variables produced by a complex model from a computer simulation. The MCS performed wen in simulating the hemodynamic variables under resting and mild exercise conditions. This novel MCS implementation provides a much more physiological meaningful tool comparing with existing MCS. It is a valuable asset for studying the physiology of the circulation, for heart assist devices testing, and for bioengineering education.
引用
收藏
页码:844 / +
页数:3
相关论文
共 50 条
  • [41] Continuous flow total artificial heart: Modeling and feedback control in a mock circulatory system
    Khalil, Hassan A.
    Kerr, Daniel T.
    Franchek, Matthew A.
    Metcalfe, Ralph W.
    Benkowski, Robert J.
    Cohn, William E.
    Tuzun, Egemen
    Radovancevic, Branislav
    Frazier, O. H.
    Kadipasaoglu, Kamuran A.
    ASAIO JOURNAL, 2008, 54 (03) : 249 - 255
  • [42] Using a Mock Circulatory Loop as a Regulatory Science Tool to Simulate Different Heart Failure Conditions
    D'Souza, Gavin A.
    Rinaldi, Jean E.
    Meki, Moustafa
    Crusan, Annabelle
    Richardson, Eric
    Shinnar, Meir
    Herbertson, Luke H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (01):
  • [43] Bridging to a Long-Term Ventricular Assist Device With Short-Term Mechanical Circulatory Support
    Kurihara, Chitaru
    Kawabori, Masashi
    Sugiura, Tadahisa
    Critsinelis, Andre C.
    Wang, Suwei
    Cohn, William E.
    Civitello, Andrew B.
    Frazier, O. H.
    Morgan, Jeffrey A.
    ARTIFICIAL ORGANS, 2018, 42 (06) : 589 - 596
  • [44] Long-term outcome after short-term mechanical circulatory support for cardiogenic shock
    Fux, T.
    Van der Linden, J.
    Grinnemo, K. H.
    Svenarud, P.
    Hultman, J.
    Gabrielsen, A.
    Lund, L. H.
    EUROPEAN HEART JOURNAL, 2010, 31 : 65 - 66
  • [45] Smart Control System based on Power Quality Parameter Short-term Forecasting
    Jahan, Ibrahim S.
    Misak, Stanislav
    Snasel, Vaclav
    2020 21ST INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2020, : 275 - 279
  • [46] Effects of short-term warm water immersion on cardiac baroreflex sensitivity in healthy men
    Jun Sugawara
    Tsubasa Tomoto
    The Journal of Physiological Sciences, 2020, 70
  • [47] Effects of Short-term Warm Water Bathing on Cardiac Baroreflex Sensitivity in Healthy Men
    Sugawara, Jun
    Tomoto, Tsubasa
    FASEB JOURNAL, 2020, 34
  • [48] Effects of nitroglycerin treatment on baroreflex sensitivity and short-term heart rate variability in humans
    Gori, T
    Floras, JS
    Parker, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (11) : 2000 - 2005
  • [49] Effects of short-term warm water immersion on cardiac baroreflex sensitivity in healthy men
    Sugawara, Jun
    Tomoto, Tsubasa
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2020, 70 (01):
  • [50] Effect of acute atenolol on short-term blood pressure variability and baroreflex sensitivity in rats
    Neto, EPD
    Frutoso, J
    Somody, L
    Gharib, C
    Fortrat, JO
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2000, 14 (04) : 341 - 349