Continuous flow total artificial heart: Modeling and feedback control in a mock circulatory system

被引:16
|
作者
Khalil, Hassan A. [1 ]
Kerr, Daniel T. [1 ]
Franchek, Matthew A. [2 ]
Metcalfe, Ralph W. [2 ]
Benkowski, Robert J.
Cohn, William E. [1 ,2 ]
Tuzun, Egemen [1 ]
Radovancevic, Branislav [1 ]
Frazier, O. H. [1 ]
Kadipasaoglu, Kamuran A. [1 ,2 ]
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Cardiovasc Surg Res Labs, Houston, TX 77225 USA
[2] Univ Houston, Houston, TX 77004 USA
关键词
D O I
10.1097/MAT.0b013e3181739b70
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a mock circulatory loop and used mathematical modeling to test the in vitro performance of a physiologic flow control system for a total artificial heart (TAH). The TAH was constructed from two continuous flow pumps. The objective of the control system was to maintain loop flow constant in response to changes in outflow resistance of either pump. Baseline outflow resistances of the right (pulmonary vascular resistance) and the left (systemic vascular resistance) pumps were set at 2 and 18 Wood units, respectively. The corresponding circuit flow was 4 L/min. The control system consisted of two digital integral controllers, each regulating the voltage, hence, the rotational speed of one of the pumps. The in vitro performance of the flow control system was validated by increasing systemic and pulmonary vascular resistances in the mock loop by 4 and 8 Wood units (simulating systemic and pulmonary hypertension conditions), respectively. For these simulated hypertensive states, the flow controllers regulated circuit flow back to 4 L/min within seconds by automatically adjusting the rotational speed of either or both pumps. We conclude that this multivariable feedback mechanism may constitute an adequate supplement to the inherent pressure sensitivity of rotary blood pumps for the automatic flow control and left-right flow balance of a dual continuous flow pump TAH system.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 50 条
  • [1] Induced pulsation of a continuous-flow total artificial heart in a mock circulatory system
    Khalil, Hassan A.
    Kerr, Daniel T.
    Schusterman, Mark A., II
    Cohn, William E.
    Frazier, O. H.
    Radovancevic, Branislav
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (05): : 568 - 573
  • [2] The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop
    Glynn, Jeremy
    Song, Howard
    Hull, Bryan
    Withers, Stanley
    Gelow, Jill
    Mudd, James
    Starr, Albert
    Wampler, Richard
    ARTIFICIAL ORGANS, 2017, 41 (10) : 904 - 910
  • [3] Performance of a Novel Shuttling Total Artificial Heart on a on a Mock Circulatory Loop
    Wampler, R.
    Glynn, J.
    Withers, S.
    Hull, B.
    Slaughter, M.
    Starr, A.
    Song, H. K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S56 - S56
  • [4] Design and evaluation of a hybrid mock circulatory loop for total artificial heart testing
    Cuenca-Navalon, Elena
    Finocchiaro, Thomas
    Laumen, Marco
    Fritschi, Andreas
    Schmitz-Rode, Thomas
    Steinseifer, Ulrich
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (01): : 71 - 80
  • [5] Mechanical Circulatory Support for Biventricular Heart Failure Using Continuous-Flow Total Artificial Heart
    Karimov, J. H.
    Horvath, D.
    Byram, N.
    Polakowski, A.
    Adams, J.
    Kado, Y.
    Miyamoto, T.
    Sale, S.
    Kuban, B.
    Fukamachi, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S343 - S343
  • [6] Feedback control design for an elastance-based mock circulatory system
    Loh, M
    Yu, YC
    PROCEEDINGS OF THE 2004 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2004, : 1639 - 1644
  • [7] An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops
    Tozzi, Piergiorgio
    Maertens, Audrey
    Emery, Jonathan
    Joseph, Samuel
    Kirsch, Matthias
    Avellan, Francois
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2017, 40 (12): : 683 - 689
  • [8] Simulated Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart Using the Virtual Mock Loop
    Miyamoto, Takuma
    Horvath, David J.
    Horvath, Dennis W.
    Karimov, Jamshid H.
    Byram, Nicole
    Kuban, Barry D.
    Fukamachi, Kiyotaka
    ASAIO JOURNAL, 2019, 65 (06) : 565 - 572
  • [9] Artificial pulse with a continuous-flow total artificial heart
    Khalil, H. A.
    Kerr, D. T.
    Schusterman, M. A., II
    Frazier, O. H.
    Radovancevic, B.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S157 - S158
  • [10] A Mock Circulatory Loop for Designing and Evaluating Total Artificial Hearts
    Love, Holley C.
    Timms, Daniel L.
    Nestler, Frank
    Frazier, O. H.
    Cohn, William E.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5667 - 5670