Continuous flow total artificial heart: Modeling and feedback control in a mock circulatory system

被引:16
|
作者
Khalil, Hassan A. [1 ]
Kerr, Daniel T. [1 ]
Franchek, Matthew A. [2 ]
Metcalfe, Ralph W. [2 ]
Benkowski, Robert J.
Cohn, William E. [1 ,2 ]
Tuzun, Egemen [1 ]
Radovancevic, Branislav [1 ]
Frazier, O. H. [1 ]
Kadipasaoglu, Kamuran A. [1 ,2 ]
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Cardiovasc Surg Res Labs, Houston, TX 77225 USA
[2] Univ Houston, Houston, TX 77004 USA
关键词
D O I
10.1097/MAT.0b013e3181739b70
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a mock circulatory loop and used mathematical modeling to test the in vitro performance of a physiologic flow control system for a total artificial heart (TAH). The TAH was constructed from two continuous flow pumps. The objective of the control system was to maintain loop flow constant in response to changes in outflow resistance of either pump. Baseline outflow resistances of the right (pulmonary vascular resistance) and the left (systemic vascular resistance) pumps were set at 2 and 18 Wood units, respectively. The corresponding circuit flow was 4 L/min. The control system consisted of two digital integral controllers, each regulating the voltage, hence, the rotational speed of one of the pumps. The in vitro performance of the flow control system was validated by increasing systemic and pulmonary vascular resistances in the mock loop by 4 and 8 Wood units (simulating systemic and pulmonary hypertension conditions), respectively. For these simulated hypertensive states, the flow controllers regulated circuit flow back to 4 L/min within seconds by automatically adjusting the rotational speed of either or both pumps. We conclude that this multivariable feedback mechanism may constitute an adequate supplement to the inherent pressure sensitivity of rotary blood pumps for the automatic flow control and left-right flow balance of a dual continuous flow pump TAH system.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 50 条
  • [41] Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System
    Selim Bozkurt
    Frans N. van de Vosse
    Marcel C. M. Rutten
    Journal of Medical and Biological Engineering, 2016, 36 : 308 - 315
  • [42] Elastance Control of a Mock Circulatory System for Ventricular Assist Device Test
    Yu, Yih-Choung
    Gopalakrishnan, Sriram
    2009 AMERICAN CONTROL CONFERENCE, VOLS 1-9, 2009, : 1009 - 1014
  • [43] Control of continuous flow artificial heart using estimated flow rate and pressure head
    Ogawa, D
    Yoshizawa, M
    Tanaka, A
    Olegario, P
    Hanaoka, T
    Shiraishi, Y
    Yambe, T
    Nitta, SI
    SICE 2004 ANNUAL CONFERENCE, VOLS 1-3, 2004, : 2099 - 2102
  • [44] Control of a mock circulatory system to simulate the short-term baroreflex
    Mushi, Simon
    Yu, Yih-Choung
    2008 AMERICAN CONTROL CONFERENCE, VOLS 1-12, 2008, : 844 - +
  • [45] Tsukuba remote monitoring system for continuous-flow artificial heart
    Kosaka, R
    Sankai, Y
    Takiya, R
    Jikuya, T
    Yamane, T
    Tsutsui, T
    ARTIFICIAL ORGANS, 2003, 27 (10) : 897 - 906
  • [46] Dynamic response of the pulmonary circulation in a continuous flow artificial heart system
    Olegario, PS
    Yoshizawa, M
    Tanaka, A
    Shiraishi, Y
    Ogawa, D
    Hanaoka, T
    Abe, K
    Yambe, T
    Nitta, S
    SICE 2004 ANNUAL CONFERENCE, VOLS 1-3, 2004, : 2225 - 2228
  • [47] Design and fabrication of a mock circulatory system for reliability tests on aortic heart valves
    Singh, Dhruv
    Singhal, Abhishek
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 753 - 754
  • [48] Eight-Year Experience with a Continuous-Flow Total Artificial Heart in Calves
    Cohn, William E.
    Handy, Kelly M.
    Parnis, Steven M.
    Conger, Jeffrey L.
    Winkler, Jo Anna
    Frazier, O. H.
    ASAIO JOURNAL, 2014, 60 (01) : 25 - 30
  • [49] Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart
    Karimov, Jamshid H.
    Steffen, Robert J.
    Byram, Nicole
    Sunagawa, Gengo
    Horvath, David
    Cruz, Vincent
    Golding, Leonard A. R.
    Fukamachi, Kiyotaka
    Moazami, Nader
    ASAIO JOURNAL, 2015, 61 (04) : 424 - 428
  • [50] In Vivo Evaluation of the Cleveland Clinic Continuous-Flow Total Artificial Heart in Calves
    Karimov, J. H.
    Fukamachi, K.
    Moazami, N.
    Kobayashi, M.
    Sale, S.
    Mielke, N.
    Sunagawa, G.
    Horvath, D.
    Gao, S.
    Golding, L. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S165 - S166