Control of a mock circulatory system to simulate the short-term baroreflex

被引:4
|
作者
Mushi, Simon [1 ]
Yu, Yih-Choung [2 ]
机构
[1] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA 22903 USA
[2] Lafayette Coll, Dept Elect & Comp Engn, Easton, PA 18042 USA
关键词
D O I
10.1109/ACC.2008.4586598
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A mock circulatory system (MCS) integrated with the baroreceptor reflex, a neurological function that regulates the mean systemic arterial pressure (P-sa) by adjusting heart rate, ventricular contractility, and systemic resistance through negative feedback, was developed to simulate the key hemodynamic variables in response to various physiological load changes. The MCS consists of two compliance chambers representing the left atrium and systemic artery, a proportional valve as a variable resistor mimicking the systemic vascular resistance (SVR), and a centrifugal pump as a current source simulating the pumping mechanism of the heart. The model of the baroreceptor reflex was implemented in software to generate the reference signals of the cardiac output (CO) and SVR. These two reference signals along with the models of the centrifugal pump and the proportional valve were used to control the rotational speed of the pump and the gap of the valve such that the desired CO and SVR can be reached. Performance of the MCS was under different cardiovascular demand levels from resting c, Atar y exercise. The test results show that this simple MCS was able to simulate the response of key hemodynamic variables comparable to the same variables produced by a complex model from a computer simulation. The MCS performed wen in simulating the hemodynamic variables under resting and mild exercise conditions. This novel MCS implementation provides a much more physiological meaningful tool comparing with existing MCS. It is a valuable asset for studying the physiology of the circulation, for heart assist devices testing, and for bioengineering education.
引用
收藏
页码:844 / +
页数:3
相关论文
共 50 条
  • [21] Short-Term Mechanical Circulatory Support Devices: Uses and Outcomes
    Kamga, Paola
    Kaira, Hatib
    Paxton, James H.
    CURRENT EMERGENCY AND HOSPITAL MEDICINE REPORTS, 2024, 12 (01) : 22 - 31
  • [22] National survey on short-term circulatory and/or respiratory support in 2009
    Baufreton, C.
    Brochet, A.
    Darrieutort, H.
    Chretien, J. -M.
    Schinkel, E. Parot
    Tanguy, M.
    Dalmayrac, E.
    Lehot, J. -J.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 (04): : 220 - 224
  • [23] Short-Term Mechanical Circulatory Support Devices: Uses and Outcomes
    Paola Kamga
    Hatib Kaira
    James H. Paxton
    Current Emergency and Hospital Medicine Reports, 2024, 12 : 22 - 31
  • [24] Recommendations for the management of patients with short-term mechanical circulatory assistance
    Rossel, Victor
    Diaz, Rodrigo
    Merello, Lorenzo
    Aranguiz-Santander, Ernesto
    Stockins, Aleck
    Olivares, Gabriel
    REVISTA MEDICA DE CHILE, 2018, 146 (01) : 96 - 106
  • [25] Relief of the left ventricle during short-term circulatory support
    Schibilsky, David
    Beyersdorf, Friedhelm
    Siepe, Matthias
    Benk, Christoph
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2022, 36 (06): : 385 - 388
  • [26] SHORT-TERM MECHANICAL CIRCULATORY SUPPORT AS BRIDGE TO HEART TRANSPLANTATION
    Absi, Daniel
    Giordanino, Elian
    Favaloro, Liliana
    Renedo, Florencia
    Rubira, Magali
    Favaloro, Roberto
    Bertolotti, Alejandro
    TRANSPLANT INTERNATIONAL, 2019, 32 : 55 - 55
  • [27] Short-term sympathetic baroreflex sensitivity increases at lower blood pressures
    van Schelven, Leonard J.
    Karemaker, John M.
    Blankestijn, Peter J.
    Oey, P. Liam
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (04) : 869 - 879
  • [28] Outcomes of a multicenter trial of the Levitronix CentriMag ventricular assist system for short-term circulatory support
    John, Ranjit
    Long, James W.
    Massey, H. Todd
    Griffith, Bartley P.
    Sun, Benjamin C.
    Tector, Alfred J.
    Frazier, O. Howard
    Joyce, Lyle D.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (04): : 932 - 939
  • [29] SHORT-TERM PRODUCTION CONTROL WITH CONTROL DESKS
    DANGELMAIER, W
    ALDINGER, L
    WERKSTATTSTECHNIK ZEITSCHRIFT FUR INDUSTRIELLE FERTIGUNG, 1986, 76 (02): : 101 - 104
  • [30] Mock tags cause a short-term decrease in takeoff velocity in House Sparrows
    Wright, Natalie
    Crawford, Katherine
    Garcia, Abigail
    Rataezyk, Olivia
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2024, 64 : S564 - S564