Accurate assessment of mitral valve area in patients with mitral stenosis by three-dimensional echocardiography

被引:55
|
作者
Chen, QW
Nosir, YFM
Vletter, WB
Kint, PP
Salustri, A
Roelandt, JRTC
机构
[1] UNIV ROTTERDAM HOSP,DIV CARDIOL,THORAXCTR,NL-3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,NL-3000 DR ROTTERDAM,NETHERLANDS
[3] DIJKZIGT UNIV,ROTTERDAM,NETHERLANDS
关键词
D O I
10.1016/S0894-7317(97)70085-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of measurements of mitral valve orifice area (MVA) from three-dimensional; echocardiographic (3DE) image data sets obtained by a transthoracic or transesophageal rotational imaging probe was studied in 15 patients with native mitral stenosis. The smallest MVA was identified from a set of eight parallel short-axis cut planes of the mitral valve between the anulus and the tips of leaflets (paraplane echocardiography) and measured by planimetry. In addition, MVA was measured from the two-dimensional short-axis view (2DE). Values of MVA measured by 3DE and 2DE were compared with those calculated from Doppler pressure half-time (PHT) as a gold standard. Observer variabilities were studied for 3DE. MVA measured from PHT ranged between 0.55 and 3.19 cm(2) (mean +/- SD 1.57 +/- 0.73 cm(2)), from 3DE between 0.83 and 3.23 cm(2) (mean +/- SD 1.55 +/- 0.67 cm(2)), and from 2DE between 1.27 and 4.08 cm(2) (mean +/- SD 1.9 +/- 0.7 cm(2)). The variability of intraobserver and interobserver measurements for 3DE measurements was not significantly different (p = 0.79 and p = 0.68, respectively); for interobserver variability, standard error of the estimate = 0.25. There was excellent correlation, close limits of agreement (mean difference +/- 2SD), and nonsignificant differences between 3DE and PHT for MVA measurements (r = 0.98 [0.02 +/- 0.3] and p = 0.6), respectively. There was moderate correlation, wider limits of agreement, and significant difference between 2DE and PHT for MVA measurements (r = 0.89 [0.32 +/- 0.66] and p = 0.002), respectively. This may be related to the difficulties in visualization of the smallest orifice in precordial short-axis views. This study suggests that three-dimensional image data sets, by providing the possibility of ''computer slicing'' to generate equidistant parallel cross sections of the mitral valve independently from physically dictated ultrasonic windows, allow accurate and reproducible measurement of the MVA.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [1] Accurate mitral valve area assessment in patients with mitral stenosis by three-dimensional echocardiography
    Nosir, YFM
    Chen, Q
    Vletter, WB
    Kint, PP
    Salustri, A
    Frowijn, R
    TenCate, FJ
    Roelandt, JRTC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 7846 - 7846
  • [2] Three-dimensional echocardiography for assessment of mitral valve stenosis
    Zamorano, Jose
    Alberto de Agustin, Jose
    CURRENT OPINION IN CARDIOLOGY, 2009, 24 (05) : 415 - 419
  • [3] Assessment of mitral valve volume by quantitative three-dimensional echocardiography in patients with rheumatic mitral valve stenosis
    Limbu, YR
    Shen, XD
    Pan, CZ
    Shi, YF
    Chen, HZ
    CLINICAL CARDIOLOGY, 1998, 21 (06) : 415 - 418
  • [4] Assessment of mitral valve volume by quantitative three-dimensional echocardiography in patients with rheumatic mitral valve stenosis - Reply
    Limbu, YR
    CLINICAL CARDIOLOGY, 1998, 21 (11) : 869 - 870
  • [5] Three-dimensional transesophageal echocardiography for determination of the mitral valve area after mitral valve repair surgery for mitral stenosis
    Kang, Woon-Seok
    Ko, Sung-Min
    Lee, Younsuk
    Oh, Chung-Sik
    Kwon, Mi-Young
    Muhammad, Hasmizy
    Kim, Seong-Hyop
    Kim, Tae-Yop
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (04): : 606 - 614
  • [6] Multiperspective Three-Dimensional Transthoracic Echocardiographic Assessment of Mitral Valve Area in Patients With Rheumatic Mitral Stenosis
    Abdelghani, Mohammad
    Ezzat, Ahmed
    Elsheikh, Hamada
    Attia, Wael M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2023, 36 (01) : 111 - 114
  • [7] Proximal flow convergence method by three-dimensional color doppler echocardiography for mitral valve area assessment in mitral stenosis
    Mejia, H.
    De Agustin Loeches, J. A.
    Viiliani, D.
    Gomez De Diego, J. J.
    Marcos-Alberca, P.
    Rodrigo, J. L.
    Almeria, C.
    Garcia-Fernandez, M. A.
    Macaya, C.
    Perez De Isla, L.
    EUROPEAN HEART JOURNAL, 2014, 35 : 623 - 623
  • [8] Proximal Flow Convergence Method by Three-Dimensional Color Doppler Echocardiography for Mitral Valve Area Assessment in Rheumatic Mitral Stenosis
    Alberto de Agustin, Jose
    Mejia, Hernan
    Viliani, Dafne
    Marcos-Alberca, Pedro
    Juan Gomez de Diego, Jose
    Javier Nunez-Gil, Ivan
    Almeria, Carlos
    Luis Rodrigo, Jose
    Luaces, Maria
    Angel Garcia-Fernandez, Miguel
    Macaya, Carlos
    Perez de Isla, Leopoldo
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (08) : 838 - 845
  • [9] Three-dimensional transesophageal echocardiography vs cardiac magnetic resonance in the assessment of planimetric mitral valve area in rheumatic mitral stenosis
    Uygur, Begum
    Celik, Omer
    Ustabasioglu, Fethi Emre
    Akinci, Okan
    Erturk, Mehmet
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (10): : 1621 - 1625
  • [10] Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
    Kupferwasser, I
    MohrKahaly, S
    Menzel, T
    Spiecker, M
    Dohmen, G
    Mayer, E
    Oelert, H
    Erbel, R
    Meyer, J
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (04): : 241 - 247