Assessment of left ventricular function with 16-and 64-slice multi-detector computed tomography

被引:22
|
作者
Abbara, Suhny [1 ,2 ]
Chow, Benjamin J. W. [1 ,2 ,3 ]
Pena, Antonio J. [1 ,2 ]
Cury, Ricardo C. [1 ,2 ]
Hoffmann, Udo [1 ,2 ]
Nieman, Koen [1 ,2 ]
Brady, Thomas J. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1N 6N5, Canada
关键词
left ventricular function; MDCT; echocardiography; SPECT; semi-automated MDCT data analysis;
D O I
10.1016/j.ejrad.2007.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed. Methods: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5 mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results. Results: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62 +/- 10% vs. 62 +/- 10%; r = 0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64 +/- 10% vs. 59 +/- 11%; r = 0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62 +/- 11% and 64 +/- 9%, respectively; r = 0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57 +/- 15% vs. 58 +/- 13%; r = 0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56 +/- 14% vs. 54 +/- 15%; r = 0.89) and between LVEF measured by 64-slice MDCT and SPECT (60 13% and 60 14%, respectively; r = 0.90). Conclusion: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [41] Dose assessment of 4-and 16-slice multi-detector computed tomography (MDCT) scanners
    Omar, R. S.
    Hashim, S.
    Ghoshal, S. K.
    Shariff, N. D.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [42] Cardiac 64-slice multi-detector computed tomography detection of infarct size in patients with post-infarct left ventricular dysfunction: A comparative study with SPECT imaging and cardiac biomarkers
    Butler, Javed
    Shapiro, Michael
    Neiman, Koen
    Nomura, Cesar
    Hoffman, Udo
    Brady, Thomas
    Cury, Ricardo
    JOURNAL OF CARDIAC FAILURE, 2006, 12 (06) : S24 - S24
  • [43] Comparison between integrated backscatter intravascular ultrasound and 64-slice multi-detector row computed tomography for tissue characterization and volumetric assessment of coronary plaques
    Yamaki, Takahiko
    Kawasaki, Masanori
    Jang, Ik-Kyung
    Raffel, Owen Christopher
    Ishihara, Yoshiyuki
    Okubo, Munenori
    Kubota, Tomoki
    Hattori, Arihiro
    Nishigaki, Kazuhiko
    Takemura, Genzou
    Fujiwara, Hisayoshi
    Minatoguchi, Shinya
    CARDIOVASCULAR ULTRASOUND, 2012, 10
  • [44] Comparison between integrated backscatter intravascular ultrasound and 64-slice multi-detector row computed tomography for tissue characterization and volumetric assessment of coronary plaques
    Takahiko Yamaki
    Masanori Kawasaki
    Ik-Kyung Jang
    Owen Christopher Raffel
    Yoshiyuki Ishihara
    Munenori Okubo
    Tomoki Kubota
    Arihiro Hattori
    Kazuhiko Nishigaki
    Genzou Takemura
    Hisayoshi Fujiwara
    Shinya Minatoguchi
    Cardiovascular Ultrasound, 10
  • [45] DIAGNOSTIC ACCURACY OF 64-SLICE MULTI-DETECTOR CORONARY COMPUTED TOMOGRAPHIC ANGIOGRAPHY: A LARGE MULTICENTER STUDY
    Gupta, Mohit
    Jug, Borut
    Papazian, Jenny
    Bhatia, Harpreet
    Karlsberg, Ronald
    Budoff, Matthew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E669 - E669
  • [46] Isolated left ventricular diverticulum in an adult: 64-slice multidetector computed tomography and echocardiography findings
    Kwon, SH
    Oh, JH
    Kim, WS
    HEART, 2009, 95 (03) : 210 - 210
  • [47] Images in cardiology: Noncompaction of the left ventricular myocardium detected by 64-slice multidetector computed tomography
    Mohrs, Oliver K.
    Magedanz, Annett
    Schlosser, Thomas
    CLINICAL CARDIOLOGY, 2007, 30 (01) : 48 - 48
  • [48] Evaluation of arterial wall Imaging with 16-slice multi-detector computed tomography
    Chan, RC
    Ferencik, M
    Wu, T
    Hoffmann, U
    Brady, TJ
    Achenbach, S
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 661 - 664
  • [49] Usefulness of three-dimensional automated quantification of left ventricular mass, volume, and function by 64-slice computed tomography
    Okuyama, Takuhiro
    Ehara, Shoichi
    Shirai, Nobuyuki
    Sugioka, Kenichi
    Ogawa, Keitaro
    Oe, Hiroki
    Kitamura, Hitoe
    Itoh, Toshihide
    Otani, Katharina
    Matsuoka, Toshiyuki
    Inoue, Yuichi
    Ueda, Makiko
    Hozumi, Takeshi
    Yoshiyama, Minoru
    JOURNAL OF CARDIOLOGY, 2008, 52 (03) : 276 - 284
  • [50] NORMAL VALUES OF LEFT VENTRICULAR FILLING INDICES BY MULTI-DETECTOR COMPUTED TOMOGRAPHY
    Hacioglu, Yalcin
    Gupta, Mohit
    Hamirani, Yasmin
    Mao, Song S.
    Choi, Tae Young
    Budoff, Matthew J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)