Assessment of left ventricular function with 16-and 64-slice multi-detector computed tomography

被引:22
|
作者
Abbara, Suhny [1 ,2 ]
Chow, Benjamin J. W. [1 ,2 ,3 ]
Pena, Antonio J. [1 ,2 ]
Cury, Ricardo C. [1 ,2 ]
Hoffmann, Udo [1 ,2 ]
Nieman, Koen [1 ,2 ]
Brady, Thomas J. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1N 6N5, Canada
关键词
left ventricular function; MDCT; echocardiography; SPECT; semi-automated MDCT data analysis;
D O I
10.1016/j.ejrad.2007.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed. Methods: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5 mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results. Results: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62 +/- 10% vs. 62 +/- 10%; r = 0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64 +/- 10% vs. 59 +/- 11%; r = 0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62 +/- 11% and 64 +/- 9%, respectively; r = 0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57 +/- 15% vs. 58 +/- 13%; r = 0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56 +/- 14% vs. 54 +/- 15%; r = 0.89) and between LVEF measured by 64-slice MDCT and SPECT (60 13% and 60 14%, respectively; r = 0.90). Conclusion: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [21] Image quality of 64-slice multi-detector computed tomography coronary angiography in heart transplant recipients
    Ferencik, M
    Gregory, SA
    Achenbach, S
    Yeh, RW
    Hoffmann, U
    Inglessis, I
    Cury, RC
    Nieman, K
    Raffel, OC
    McNulty, IA
    Brady, TJ
    Semigran, MJ
    Jang, IK
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 130A - 130A
  • [22] Value of 64-slice multi-detector computed tomography for predicting revascularization in patients with coronary artery disease
    Lim, H. S.
    Tahk, S. J.
    Yang, H. M.
    Park, J. S.
    Zheng, M.
    Kim, S. K.
    Kwon, Y. S.
    Choi, B. J.
    Choi, S. Y.
    Yoon, M. H.
    EUROPEAN HEART JOURNAL, 2009, 30 : 210 - 211
  • [23] Image quality of 64-slice multi-detector computed tomography coronary angiograpry in heart transplant recipients
    Ferencik, M.
    Gregory, S. A.
    Achenbach, S.
    Yeh, R. W.
    Hoffmann, U.
    Inglessis, I.
    Cury, R. C.
    Nieman, K.
    Raffel, O. C.
    McNulty, I. A.
    Brady, T. J.
    Semigran, M. J.
    Jang, I. K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (02): : S140 - S140
  • [24] Large left ventricular pseudoaneurysm detected by 64-slice computed tomography
    Bayrak, Fatih
    Eroglu, Basak Torum
    Beykal, Omer
    Degertekin, Muzaffer
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2008, 36 (07): : 498 - 498
  • [25] Randomized comparison of dual source computed tomography and 64-slice multi-detector computed tomography for the detection of coronary artery stenoses
    Ropers, Ulrike
    Karakaya, Sultan
    Wechsel, Martin
    Anders, Katharina
    Ropers, Dieter
    Kuettner, Axel
    Daniel, Werner G.
    Kalender, Willi
    Baut, Werner
    Achenbach, Stephan
    CIRCULATION, 2006, 114 (18) : 448 - 448
  • [26] Coronary stent assessability by 64 slice multi-detector computed tomography
    Sheth, Tei
    Dodd, Jonathan
    Finn, Alok
    Gold, Herman
    Cury, Ricardo C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 25B - 26B
  • [27] Real-time three-dimensional echocardiographic left ventricular systolic assessment: side-by-side comparison with 64-slice multi-detector cardiac computed tomography
    Vieira, Marcelo L. C.
    Nomura, Cesar H.
    Tranchesi, Bernardino, Jr.
    de Oliveira, Wercules A.
    Naccarato, Gustavo
    Serpa, Bruna S.
    Passos, Rodrigo B. D.
    Funari, Marcelo B. G.
    Fischer, Claudio H.
    Morhy, Samira S.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (03): : 257 - 263
  • [28] Coronary stent assessability by 64 slice multi-detector computed tomography
    Sheth, Tej
    Dodd, Jonathan D.
    Hoffmann, Udo
    Abbara, Suhny
    Finn, Aloke
    Gold, Herman K.
    Brady, Thomas J.
    Cury, Ricardo C.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (07) : 933 - 938
  • [29] USEFULNESS OF PLAQUE ASSESSMENT BY 64-SLICE MULTI-DETECTOR COMPUTED TOMOGRAPHY FOR PREDICTING STENTING-RELATED PERIPROCEDURAL MYOCARDIAL INFARCTION
    Murakami, Tomoe
    Kawase, Yuichi
    Shimamoto, Shinsaku
    Ueda, Hiroshi
    Sakamoto, Hiroki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [30] Clinically significant non-cardiac findings are common in 64-slice multi-detector computed tomography of the heart
    Zimbwa, Peter
    Narayan, Shoba B.
    Schoenhagen, Paul
    Desai, Milind Y.
    Garcia, Mario J.
    Sola, Srikanth