Assessment of left ventricular function with 16-and 64-slice multi-detector computed tomography

被引:22
|
作者
Abbara, Suhny [1 ,2 ]
Chow, Benjamin J. W. [1 ,2 ,3 ]
Pena, Antonio J. [1 ,2 ]
Cury, Ricardo C. [1 ,2 ]
Hoffmann, Udo [1 ,2 ]
Nieman, Koen [1 ,2 ]
Brady, Thomas J. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1N 6N5, Canada
关键词
left ventricular function; MDCT; echocardiography; SPECT; semi-automated MDCT data analysis;
D O I
10.1016/j.ejrad.2007.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed. Methods: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5 mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results. Results: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62 +/- 10% vs. 62 +/- 10%; r = 0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64 +/- 10% vs. 59 +/- 11%; r = 0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62 +/- 11% and 64 +/- 9%, respectively; r = 0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57 +/- 15% vs. 58 +/- 13%; r = 0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56 +/- 14% vs. 54 +/- 15%; r = 0.89) and between LVEF measured by 64-slice MDCT and SPECT (60 13% and 60 14%, respectively; r = 0.90). Conclusion: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [11] Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT
    Sanjay Doddamani
    Michael J. Grushko
    Amgad N. Makaryus
    Vineet R. Jain
    Ricardo Bello
    Mark A. Friedman
    Robert J. Ostfeld
    Divya Malhotra
    Lawrence M. Boxt
    Linda Haramati
    Daniel M. Spevack
    The International Journal of Cardiovascular Imaging, 2009, 25 : 175 - 181
  • [12] Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging
    Zhang Xiao-chun
    Yang Zhi-gang
    Guo Yin-kun
    Zhang Rui-ming
    Wang Jian
    Zhou Dai-quan
    Cheng Lin
    Chen Lin
    CHINESE MEDICAL JOURNAL, 2012, 125 (08) : 1469 - 1474
  • [13] Analysis of shielding calculation methods for 16-and 64-slice computed tomography facilities
    Moreno, C.
    Cenizo, E.
    Bodineau, C.
    Mateo, B.
    Ortega, E. M.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2010, 30 (03) : 557 - 565
  • [14] Left ventricular functional analysis using 64-slice multi-detector row computed tomography: Comparison with echocardiography, cardiovascular magnetic resonance and left ventriculography
    Wu, Yen-Wen
    Tadamura, Eiji
    Kanao, Shotaro
    Yamamuro, Masaki
    Togashi, Kaori
    CIRCULATION, 2006, 114 (18) : 496 - 496
  • [15] The role of 64-slice multi-detector computed tomography in the detection of subclinical atherosclerosis of the coronary artery
    Hae Chang Jeong
    Youngkeun Ahn
    Jum Suk Ko
    Min Goo Lee
    Doo Sun Sim
    Keun Ho Park
    Nam Sik Yoon
    Hyun Ju Youn
    Young Joon Hong
    Kye Hun Kim
    Hyung Wook Park
    Ju Han Kim
    Yun-Hyeon Kim
    Myung Ho Jeong
    Jeong Gwan Cho
    Jong Chun Park
    Jung Chaee Kang
    The International Journal of Cardiovascular Imaging, 2010, 26 : 253 - 259
  • [16] The role of 64-slice multi-detector computed tomography in the detection of subclinical atherosclerosis of the coronary artery
    Jeong, Hae Chang
    Ahn, Youngkeun
    Ko, Jum Suk
    Lee, Min Goo
    Sim, Doo Sun
    Park, Keun Ho
    Yoon, Nam Sik
    Youn, Hyun Ju
    Hong, Young Joon
    Kim, Kye Hun
    Park, Hyung Wook
    Kim, Ju Han
    Kim, Yun-Hyeon
    Jeong, Myung Ho
    Cho, Jeong Gwan
    Park, Jong Chun
    Kang, Jung Chaee
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 253 - 259
  • [17] EVALUATION OF LEFT ATRIAL VOLUME AND DIAMETER BY 64-SLICE MULTI DETECTOR COMPUTED TOMOGRAPHY
    Honoris, Lily
    Zeb, Irfan
    Buckley, Luan C.
    Li, Dong
    Gao, Yanlin
    Flores, Ferdinand
    Mao, Songshou
    Budoff, Matthew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1203 - E1203
  • [18] Normal reference range for left ventricular volumes and ejection fraction by 64 slice multi-detector computed tomography
    Abraham, A.
    Dennie, C.
    Ruddy, T. D.
    Beanlands, R. S.
    Chow, B. J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 72C - 72C
  • [19] Comparison of 64-slice computed tomography with gated spect for evaluation of left ventricular function
    Schepis, T.
    Gaemperli, O.
    Strobel, K.
    Koepfli, P.
    Leschka, S.
    Desbiolles, L.
    Husmann, L.
    Hany, T.
    von Schulthess, G. K.
    Alkadhi, H.
    Kaufmann, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S129 - S129
  • [20] Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography
    Ferencik, Maros
    Gregory, Shawn A.
    Butler, Javed
    Achenbach, Stephan
    Yeh, Robert W.
    Hoffmann, Udo
    Inglessis, Ignacio
    Cury, Ricardo C.
    Nieman, Koen
    McNulty, Iris A.
    Healy, Josephine A.
    Brady, Thomas J.
    Semigran, Marc J.
    Jang, Ik-Kyung
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (05): : 478 - 484