Assessment of left ventricular function with 16-and 64-slice multi-detector computed tomography

被引:22
|
作者
Abbara, Suhny [1 ,2 ]
Chow, Benjamin J. W. [1 ,2 ,3 ]
Pena, Antonio J. [1 ,2 ]
Cury, Ricardo C. [1 ,2 ]
Hoffmann, Udo [1 ,2 ]
Nieman, Koen [1 ,2 ]
Brady, Thomas J. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1N 6N5, Canada
关键词
left ventricular function; MDCT; echocardiography; SPECT; semi-automated MDCT data analysis;
D O I
10.1016/j.ejrad.2007.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed. Methods: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5 mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results. Results: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62 +/- 10% vs. 62 +/- 10%; r = 0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64 +/- 10% vs. 59 +/- 11%; r = 0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62 +/- 11% and 64 +/- 9%, respectively; r = 0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57 +/- 15% vs. 58 +/- 13%; r = 0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56 +/- 14% vs. 54 +/- 15%; r = 0.89) and between LVEF measured by 64-slice MDCT and SPECT (60 13% and 60 14%, respectively; r = 0.90). Conclusion: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [1] Left Ventricular Anatomy and Geometry by 64-slice Multi-Detector Computed Tomography in Patients with Low Left Ventricular Function
    Yoshida, Shohei
    Toda, Koichi
    Fukushima, Satsuki
    Yoshikawa, Yasushi
    Nakamura, Teruya
    Miyagawa, Shigeru
    Saito, Shunsuke
    Yoshioka, Daisuke
    Kuratani, Toru
    Sawa, Yoshiki
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (10) : S196 - S196
  • [2] Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography
    Rixe, Johannes
    Achenbach, Stephan
    Ropers, Dieter
    Baum, Ulrich
    Kuettner, Axel
    Ropers, Ulrike
    Bautz, Werner
    Daniel, Werner G.
    Anders, Katharina
    EUROPEAN HEART JOURNAL, 2006, 27 (21) : 2567 - 2572
  • [3] Noninvasive assessment of patients with aortic stenosis by 64-slice multi-detector computed tomography
    Yachi, S.
    Tanabe, K.
    Tanimoto, S.
    Yamamoto, H.
    Otsuki, S.
    Yagishita, A.
    Nakajima, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2008, 29 : 245 - 246
  • [4] Winslow's pathway in 64-slice multi-detector computed tomography
    Takahashi, Saeko
    Kaneda, Hideaki
    Saito, Shigeru
    EUROPEAN HEART JOURNAL, 2007, 28 (20) : 2437 - 2437
  • [5] Evaluation of constrictive pericarditis by 64-slice multi-detector computed tomography
    Sola, Srikanth
    Sayeed, Mohammed R.
    Gillinov, Alan Marc
    EUROPEAN HEART JOURNAL, 2007, 28 (02) : 149 - 149
  • [6] Evaluation of cardiac function and myocardial viability with 16-and 64-slice multidetector computed tomography
    Kopp, AF
    Heuschmid, M
    Reimann, A
    Kuettner, A
    Beck, T
    Ohmer, M
    Burgstahler, C
    Brodoefel, H
    Claussen, CD
    Schroeder, S
    EUROPEAN RADIOLOGY, 2005, 15 : D15 - D20
  • [7] Assessment of coronary artery stent patency by 64-slice multi-detector computed tomography: Predictors of evaluability
    Rixe, J.
    Anders, K.
    Ropers, D.
    Kuettner, A.
    Baum, U.
    Ludwig, J.
    Daniel, W. G.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 427 - 428
  • [8] Noninvasive angiographic assessment of coronary artery stent patency by 64-slice multi-detector computed tomography
    Johannes, R
    Anders, K
    Ropers, D
    Baum, U
    Kuettner, A
    Daniel, WG
    Achenbach, S
    CIRCULATION, 2005, 112 (17) : U621 - U621
  • [9] Thick maximum intensity projections for the assessment of left ventricular function with 64-slice computed tomography
    Husmann, Lars
    Leschka, Sebastian
    Desbiolles, Lotus
    Schepis, Tiziano
    Koepfli, Pascal
    Gaemperli, Oliver
    Seifert, Burkhardt
    Flohr, Thomas G.
    Frauenfelder, Thomas
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2006, 41 (10) : 746 - 752
  • [10] Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT
    Doddamani, Sanjay
    Grushko, Michael J.
    Makaryus, Amgad N.
    Jain, Vineet R.
    Bello, Ricardo
    Friedman, Mark A.
    Ostfeld, Robert J.
    Malhotra, Divya
    Boxt, Lawrence M.
    Haramati, Linda
    Spevack, Daniel M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (02): : 175 - 181