Generation and dose distribution measurement of flash x-ray in KALI-5000 system

被引:17
|
作者
Menon, Rakhee [1 ]
Roy, Amitava [1 ]
Mitra, S. [1 ]
Sharma, A. [1 ]
Mondal, J. [1 ]
Mittal, K. C. [1 ]
Nagesh, K. V. [1 ]
Chakravarthy, D. P. [1 ]
机构
[1] Bhabha Atom Res Ctr, Accelerator & Pulse Power Div, Bombay 400085, Maharashtra, India
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 10期
关键词
bremsstrahlung; calcium compounds; dosimetry; dysprosium; photomultipliers; relativistic electron beams; scintillation counters; tantalum; thermoluminescence; X-ray production;
D O I
10.1063/1.3005485
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Flash x-ray generation studies have been carried out in KALI-5000 Pulse power system. The intense relativistic electron beam has been bombarded on a tantalum target at anode to produce flash x-ray via bremsstrahlung conversion. The typical electron beam parameter was 360 kV, 18 kA, and 100 ns, with a few hundreds of A/cm(2) current density. The x-ray dose has been measured with calcium sulfate:dysposium (CaSO(4):Dy) thermoluminescent dosimeter and the axial dose distribution has been characterized. It has been observed that the on axis dose falls of with distance similar to 1/x(n), where n varies from 1.8 to 1.85. A maximum on axis dose of 46 mrad has been measured at 1 m distance from the source. A plastic scintillator with optical fiber coupled to a photomultiplier tube has been developed to measure the x-ray pulse width. The typical x-ray pulse width varied from 50 to 80 ns.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Measurement of patient exposure dose on X-ray screening mammography
    Goto, S
    Azuma, Y
    Sumimoto, T
    Maruyama, T
    Eiho, S
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 191 - 196
  • [42] Generation of X-ray fluctuations in X-ray binaries
    Mineshige, S
    Takeuchi, M
    Negoro, H
    CATACLYSMIC VARIABLES AND RELATED OBJECTS, 1996, 208 : 359 - 362
  • [43] A COMPUTERIZED X-RAY DOSE-MONITORING SYSTEM
    HUMMEL, RH
    WESENBERG, RL
    AMUNDSON, GM
    RADIOLOGY, 1985, 156 (01) : 231 - 234
  • [44] DEPTH DOSE DISTRIBUTION FROM DENTAL X-RAY BEAMS
    GIBBS, SJ
    KING, RJ
    PUJOL, A
    WU, W
    JOURNAL OF DENTAL RESEARCH, 1976, 55 : B247 - B247
  • [45] ON THE INTERPRETATION OF X-RAY FLASH SPECTRA
    SCHORLING, PO
    ARKIV FOR FYSIK, 1962, 21 (04): : 371 - 381
  • [46] TRIGGERING SYSTEMS FOR FLASH X-RAY
    FRANCIS, L
    MATERIALS EVALUATION, 1977, 35 (06) : 19 - 19
  • [47] ON THE INTERPRETATION OF X-RAY FLASH SPECTRA
    SCHORLING, PO
    ARKIV FOR FYSIK, 1962, 22 (05): : 434 - 435
  • [48] MOLECULAR PHOTOGRAPHY WITH AN X-RAY FLASH
    POOL, R
    SCIENCE, 1988, 241 (4863) : 295 - 295
  • [49] PROGRESS IN X-RAY - FLASH - TECHNICS
    RODEWALD, HJ
    MICROTECNIC, 1966, 20 (04): : 381 - &
  • [50] ADVANCES IN X-RAY FLASH TECHNIQUE
    RODEWALD, HJ
    METALL, 1966, 20 (10): : 1057 - &