Generation and dose distribution measurement of flash x-ray in KALI-5000 system

被引:17
|
作者
Menon, Rakhee [1 ]
Roy, Amitava [1 ]
Mitra, S. [1 ]
Sharma, A. [1 ]
Mondal, J. [1 ]
Mittal, K. C. [1 ]
Nagesh, K. V. [1 ]
Chakravarthy, D. P. [1 ]
机构
[1] Bhabha Atom Res Ctr, Accelerator & Pulse Power Div, Bombay 400085, Maharashtra, India
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 10期
关键词
bremsstrahlung; calcium compounds; dosimetry; dysprosium; photomultipliers; relativistic electron beams; scintillation counters; tantalum; thermoluminescence; X-ray production;
D O I
10.1063/1.3005485
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Flash x-ray generation studies have been carried out in KALI-5000 Pulse power system. The intense relativistic electron beam has been bombarded on a tantalum target at anode to produce flash x-ray via bremsstrahlung conversion. The typical electron beam parameter was 360 kV, 18 kA, and 100 ns, with a few hundreds of A/cm(2) current density. The x-ray dose has been measured with calcium sulfate:dysposium (CaSO(4):Dy) thermoluminescent dosimeter and the axial dose distribution has been characterized. It has been observed that the on axis dose falls of with distance similar to 1/x(n), where n varies from 1.8 to 1.85. A maximum on axis dose of 46 mrad has been measured at 1 m distance from the source. A plastic scintillator with optical fiber coupled to a photomultiplier tube has been developed to measure the x-ray pulse width. The typical x-ray pulse width varied from 50 to 80 ns.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Development of cable fed flash X-ray (FXR) system
    Menon, Rakhee
    Mitra, S.
    Patel, A. S.
    Kumar, R.
    Singh, G.
    Senthil, K.
    Kumar, Ranjeet
    Kolge, T. S.
    Roy, Amitava
    Acharya, S.
    Biswas, D.
    Sharma, Archana
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (08):
  • [32] X-RAY MEASUREMENT OF THE DISTRIBUTION OF ELECTRONS IN IRON AND COPPER
    WEISS, RJ
    DEMARCO, JJ
    PHYSICAL REVIEW LETTERS, 1959, 2 (04) : 148 - 149
  • [33] OPERATING CHARACTERISTICS IN A LOW INDUCTANCE FLASH X-RAY SYSTEM
    HANDEL, SK
    ARKIV FOR FYSIK, 1965, 28 (04): : 303 - &
  • [34] Analysis of X-ray interferometers for phase distribution measurement
    Nakano, T
    Hagino, H
    Kikuta, H
    Iwata, K
    17TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR SCIENCE AND NEW TECHNOLOGY, PTS 1 AND 2, 1996, 2778 : 17 - 18
  • [35] Lateral distribution of photoelectrons and the measurement of x-ray polarization
    Hare, DG
    Kirkpatrick, P
    PHYSICAL REVIEW, 1933, 43 (12): : 1037 - 1037
  • [36] X-RAY MEASUREMENT OF THE DISTRIBUTION OF ELECTRONS IN IRON AND COPPER
    BATTERMAN, BW
    PHYSICAL REVIEW LETTERS, 1959, 2 (02) : 47 - 48
  • [37] CORRELATED ELECTRICAL AND X-RAY MEASUREMENTS IN FLASH X-RAY DISCHARGES
    HANDEL, SK
    BERG, JM
    ARKIV FOR FYSIK, 1966, 31 (01): : 1 - +
  • [38] Flash X-ray tube for X-ray photoelectron studies of melts
    Trapeznikov, VA
    Shirobokov, SV
    Kovner, LG
    JOURNAL OF STRUCTURAL CHEMISTRY, 1998, 39 (06) : 956 - 957
  • [39] Flash X-ray tube for X-ray photoelectron studies of melts
    V. A. Trapeznikov
    S. V. Shirobokov
    L. G. Kovner
    Journal of Structural Chemistry, 1998, 39 : 956 - 957
  • [40] PYROLITIC GRAPHITE MICROCALORIMETER FOR MEASUREMENT OF X-RAY ABSORBED DOSE
    KEMP, LAW
    MARSH, ARS
    BAKER, MJ
    NATURE, 1971, 230 (5288) : 41 - +