New UV spectral responsivity scale of the PTB based on a cryogenic radiometer and an argon plasma arc radiation source

被引:19
|
作者
Meindl, P. [1 ]
Klinkmueller, A. E. [1 ]
Werner, L. [1 ]
Johannsen, U. [1 ]
Gruetzmacher, K. [1 ]
机构
[1] Phys Tech Bundesanstalt, Inst Berlin, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/43/2/S15
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cryogenic-radiometer-based calibration facility utilizing monochromatized radiation of an argon arc plasma has been put into operation at the PTB. The high radiance of the plasma Source allows us to improve the accuracy of the UV spectral responsivity scale between 200 nm and 410 nm and to achieve relative standard uncertainties of about 0.1% to 0.2%. Comparison with the PTB laser-based cryogenic radiometer at five laser lines in the UV indicated excellent agreement.
引用
收藏
页码:S72 / S77
页数:6
相关论文
共 36 条
  • [1] Realization of the spectral responsivity scale based on an absolute cryogenic radiometer
    Kee-Suk Hong
    Seongchong Park
    Seung-Kwan Kim
    Seung-Nam Park
    Dong-Hoon Lee
    Journal of the Korean Physical Society, 2015, 67 : 2045 - 2058
  • [2] Realization of the spectral responsivity scale based on an absolute cryogenic radiometer
    Hong, Kee-Suk
    Park, Seongchong
    Kim, Seung-Kwan
    Park, Seung-Nam
    Lee, Dong-Hoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (12) : 2045 - 2058
  • [3] Precise scale of spectral responsivity for InGaAs detectors based on a cryogenic radiometer and several laser sources
    Werner, L
    Friedrich, R
    Johannsen, U
    Steiger, A
    METROLOGIA, 2000, 37 (05) : 523 - 526
  • [4] The new ultraviolet spectral responsivity scale based on cryogenic radiometry at Synchrotron Ultraviolet Radiation Facility III
    Shaw, PS
    Larason, TC
    Gupta, R
    Brown, SW
    Vest, RE
    Lykke, KR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (05): : 2242 - 2247
  • [5] New PTB Setup for the Absolute Calibration of the Spectral Responsivity of Radiation Thermometers
    K. Anhalt
    A. Zelenjuk
    D. R. Taubert
    T. Keawprasert
    J. Hartmann
    International Journal of Thermophysics, 2009, 30 : 192 - 202
  • [6] New PTB Setup for the Absolute Calibration of the Spectral Responsivity of Radiation Thermometers
    Anhalt, K.
    Zelenjuk, A.
    Taubert, D. R.
    Keawprasert, T.
    Hartmann, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2009, 30 (01) : 192 - 202
  • [7] The technique of measuring absolute spectral responsivity of InGaAs detector based on cryogenic radiometer
    Fan, JH
    Yang, ZJ
    Hou, XQ
    Qin, Y
    Li, ZQ
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150
  • [8] Absolute spectral responsivity of silicon trap detector based on absolute cryogenic radiometer
    Shi, Xueshun
    Liu, Changming
    Liu, Yulong
    Yang, Lechen
    Zhao, Kun
    Chen, Haidong
    INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
  • [9] First results with the new PTB cryogenic radiometer for the vacuum-ultraviolet spectral range
    LauFrambs, A
    Kroth, U
    Rabus, H
    Tegeler, E
    Ulm, G
    Wende, B
    METROLOGIA, 1996, 32 (06) : 571 - 574
  • [10] Electrical substitution cryogenic radiometer based spectral responsivity scale between 250-2500 nm wavelengths
    Bazkir, Ö
    Samedov, F
    OPTICA APPLICATA, 2004, 34 (03) : 427 - 438