Experimental investigation of design parameters on dry powder inhaler performance

被引:16
|
作者
Nguyen Thi Quynh Ngoc [1 ]
Chang, Lusi [1 ]
Jia, Xinli [1 ]
Lau, Raymond [1 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 639798, Singapore
关键词
Dry powder inhaler; Flow field; Turbulence intensity; In vitro deposition; Emitted dose; Fine particle fraction; COMPUTATIONAL FLUID-DYNAMICS; POLLEN-SHAPE CARRIER; AIR-FLOW; INHALATION PERFORMANCE; DRUG-DELIVERY; PARTICLE-SIZE; DEVICE DESIGN; FORMULATION; DISPERSION; DEPOSITION;
D O I
10.1016/j.ijpharm.2013.08.072
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The study aims to investigate the impact of various design parameters of a dry powder inhaler on the turbulence intensities generated and the performance of the dry powder inhaler. The flow fields and turbulence intensities in the dry powder inhaler are measured using particle image velocimetry (PIV) techniques. In vitro aerosolization and deposition a blend of budesonide and lactose are measured using an Andersen Cascade Impactor. Design parameters such as inhaler grid hole diameter, grid voidage and chamber length are considered. The experimental results reveal that the hole diameter on the grid has negligible impact on the turbulence intensity generated in the chamber. On the other hand, hole diameters smaller than a critical size can lead to performance degradation due to excessive particle-grid collisions. An increase in grid voidage can improve the inhaler performance but the effect diminishes at high grid voidage. An increase in the chamber length can enhance the turbulence intensity generated but also increases the powder adhesion on the inhaler wall. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [41] FORMULATION OPTIMIZATION AND PERFORMANCE OF THE MICRONIZER - A NOVEL ACTIVE DRY POWDER INHALER
    Wagenseil, L.
    Steckel, H.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (05) : A12 - A12
  • [42] INFLUENCE OF BLENDER TYPE ON THE PERFORMANCE OF TERNARY DRY POWDER INHALER FORMULATIONS
    Hertel, M.
    Schwarz, E.
    Littringer, E. M.
    Dogru, M.
    Hauptstein, S.
    Steckel, H.
    Scherliess, R.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (04) : A16 - A16
  • [43] Optimization of Carrier-Based Dry Powder Inhaler Performance: A Review
    Mehta, Tanu
    Najafian, Saeed
    Patel, Komalkumar
    Lacombe, Justin
    Chaudhuri, Bodhisattwa
    PHARMACEUTICS, 2025, 17 (01)
  • [44] Developing Dry Powder Inhaler Formulations
    Morton, David A. V.
    Barling, David
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2024, 37 (02) : 90 - 99
  • [45] Novolizer® -: A multidose dry powder inhaler
    Fenton, C
    Keating, GM
    Plosker, GL
    DRUGS, 2003, 63 (22) : 2437 - 2445
  • [46] Liposomal amikacin dry powder inhaler: Effect of fines on in vitro performance
    Shrenik P. Shah
    Ambikanandan Misra
    AAPS PharmSciTech, 5
  • [47] Liposomal amikacin dry powder inhaler: Effect of fines on in vitro performance
    Shah, SP
    Misra, A
    AAPS PHARMSCITECH, 2004, 5 (04)
  • [48] Performance Testing for Dry Powder Inhaler Products: Towards Clinical Relevance
    Maloney, Sara E.
    Mecham, Jeffrey B.
    Hickey, Anthony J.
    KONA POWDER AND PARTICLE JOURNAL, 2023, 40 (40) : 172 - 185
  • [49] Dynamics of aerosol generation and release - Dry powder inhaler performance considerations
    Dorosz, Agata
    Zaczek, Marta
    Moskal, Arkadiusz
    JOURNAL OF AEROSOL SCIENCE, 2021, 151
  • [50] Influence of Mouthpiece Geometry on the Aerosol Delivery Performance of a Dry Powder Inhaler
    Matthew S. Coates
    Hak-Kim Chan
    David F. Fletcher
    Herbert Chiou