Experimental investigation of design parameters on dry powder inhaler performance

被引:16
|
作者
Nguyen Thi Quynh Ngoc [1 ]
Chang, Lusi [1 ]
Jia, Xinli [1 ]
Lau, Raymond [1 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 639798, Singapore
关键词
Dry powder inhaler; Flow field; Turbulence intensity; In vitro deposition; Emitted dose; Fine particle fraction; COMPUTATIONAL FLUID-DYNAMICS; POLLEN-SHAPE CARRIER; AIR-FLOW; INHALATION PERFORMANCE; DRUG-DELIVERY; PARTICLE-SIZE; DEVICE DESIGN; FORMULATION; DISPERSION; DEPOSITION;
D O I
10.1016/j.ijpharm.2013.08.072
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The study aims to investigate the impact of various design parameters of a dry powder inhaler on the turbulence intensities generated and the performance of the dry powder inhaler. The flow fields and turbulence intensities in the dry powder inhaler are measured using particle image velocimetry (PIV) techniques. In vitro aerosolization and deposition a blend of budesonide and lactose are measured using an Andersen Cascade Impactor. Design parameters such as inhaler grid hole diameter, grid voidage and chamber length are considered. The experimental results reveal that the hole diameter on the grid has negligible impact on the turbulence intensity generated in the chamber. On the other hand, hole diameters smaller than a critical size can lead to performance degradation due to excessive particle-grid collisions. An increase in grid voidage can improve the inhaler performance but the effect diminishes at high grid voidage. An increase in the chamber length can enhance the turbulence intensity generated but also increases the powder adhesion on the inhaler wall. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [31] The Genuair® inhaler: a novel, multidose dry powder inhaler
    Chrystyn, H.
    Niederlaender, C.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2012, 66 (03) : 309 - 317
  • [32] Investigation of Appropriate Inhalation Technique for Mometasone Furoate Dry Powder Inhaler
    Yokoyama, Haruko
    Ito, Kanako
    Mihashi, Hirokazu
    Shiraishi, Yasuyuki
    Takayanagi, Risa
    Yamada, Yasuhiko
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2016, 39 (10) : 1576 - 1580
  • [33] Computational modelling and experimental validation of drug entrainment in a dry powder inhaler
    Kopsch, Thomas
    Murnane, Darragh
    Symons, Digby
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 553 (1-2) : 37 - 46
  • [34] Capabilities and limitations of using powder rheology and permeability to predict dry powder inhaler performance
    Cordts, Eike
    Steckel, Hartwig
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2012, 82 (02) : 417 - 423
  • [35] Effect of Inhaler Design Variables on Paediatric Use of Dry Powder Inhalers
    Lexmond, Anne J.
    Kruizinga, Tonnis J.
    Hagedoorn, Paul
    Rottier, Bart L.
    Frijlink, Henderik W.
    de Boer, Anne H.
    PLOS ONE, 2014, 9 (06):
  • [36] DESIGN AND DEVELOPMENT OF A DISPOSABLE HIGH DOSE DRY POWDER INHALER FOR AMINOGLYCOSIDES
    Hoppentocht, M.
    Hagedoorn, P.
    Frijlink, H. W.
    de Boer, A. H.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2014, 27 (04) : A22 - A22
  • [37] AN OVERVIEW OF THE DESIGN VERIFICATION TESTING PROCESS FOR THE GYROHALER® DRY POWDER INHALER
    Reece, Claire
    Swanbury, Phil
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (04) : A24 - A24
  • [38] Structure Design and Turbulence Simulation of Disaggregation Pipe in Dry Powder Inhaler
    Zhang, Xiankui
    Liu, Tianyi
    ADVANCES IN MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 220-223 : 1727 - 1731
  • [39] Novolizer®A Multidose Dry Powder Inhaler
    Caroline Fenton
    Gillian M. Keating
    Greg L. Plosker
    Drugs, 2003, 63 : 2437 - 2445
  • [40] Influence of mouthpiece geometry on the aerosol delivery performance of a dry powder inhaler
    Coates, Matthew S.
    Chan, Hak-Kim
    Fletcher, David F.
    Chiou, Herbert
    PHARMACEUTICAL RESEARCH, 2007, 24 (08) : 1450 - 1456