Shock Efficacy of Subcutaneous Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death Initial Multicenter Experience

被引:58
|
作者
Aydin, Ali [1 ]
Hartel, Friederike [1 ]
Schlueter, Michael [1 ]
Butter, Christian [3 ]
Koebe, Julia [4 ,5 ]
Seifert, Martin [3 ]
Gosau, Nils [1 ]
Hoffmann, Boris [1 ]
Hoffmann, Matthias [1 ]
Vettorazzi, Eik [6 ]
Wilke, Iris [1 ]
Wegscheider, Karl [6 ]
Reichenspurner, Hermann [2 ]
Eckardt, Lars [4 ,5 ]
Steven, Daniel [1 ]
Willems, Stephan [1 ]
机构
[1] Univ Heart Ctr, Dept Electrophysiol, Hamburg, Germany
[2] Univ Heart Ctr, Dept Cardiac Surg, Hamburg, Germany
[3] Heart Ctr Brandenburg Bernau, Dept Cardiol, Berlin, Germany
[4] Hosp Westfal Wilhelms Univ, Dept Cardiol, Div Expt & Clin Electrophysiol, Munster, Germany
[5] Hosp Westfal Wilhelms Univ, Dept Angiol, Div Expt & Clin Electrophysiol, Munster, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Med Biometry & Epidemiol, Ctr Med Expt, D-20246 Hamburg, Germany
来源
关键词
implantable cardioverter-defibrillator; ventricular tachyarrhythmia; implantable cardioverter-defibrillator shock failure; defibrillation threshold; subcutaneous implantable cardioverter-defibrillator; CLINICAL-EXPERIENCE; ICD THERAPY; MANAGEMENT;
D O I
10.1161/CIRCEP.112.973339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Recently, subcutaneous implantable cardioverter-defibrillator (S-ICD) has become available. The aim of our study was to assess the efficacy of S-ICD in a clinical setting. Methods and Results-Between June 2010 and July 2011, 40 consecutive patients (42 +/- 15 years; body mass index, 27 +/- 6 kg/m(2); left ventricular ejection fraction, 47 +/- 15%; 28 men) received an S-ICD for primary (n=17) or secondary prevention (n=23 [58%]) at 3 institutions in Germany. Intraoperative defibrillation efficacy testing failed in 1 patient with severely reduced left ventricular ejection fraction; testing was effective in all other patients. All episodes stored in the S-ICD were analyzed for appropriate and inappropriate detection, as well as effective shock delivery to convert ventricular tachyarrhythmia into sinus rhythm. During a median follow-up of 229 (interquartile range, 116-305) days, 4 patients experienced 21 episodes, with correct detection of ventricular tachyarrhythmia and subsequent shock therapy. A total of 28 shocks were delivered in these 4 patients. Mixed logistic regression modeling revealed a shock efficacy of 96.4% (95% CI, 12.8%-100%). The efficacy of first shocks, however, was only 57.9% (95% CI, 35.6%-77.4%). Four episodes were incorrectly classified as ventricular tachyarrhythmia, which led to inappropriate shock delivery in 2 patients. Conclusions-Ineffective shock delivery may occur in patients with S-ICD, even after successful intraoperative testing. Multicenter trials are required with close monitoring of safety and efficacy end points to identify patients who may be at risk for shock failure. (Circ Arrhythm Electrophysiol. 2012;5:913-919.)
引用
收藏
页码:913 / 919
页数:7
相关论文
共 50 条
  • [41] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - A NEW APPROACH TO PREVENT SUDDEN CARDIAC DEATH
    KLEIN, H
    FRANK, G
    KUHN, E
    BORST, HG
    LICHTLEN, PR
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A57 - A57
  • [42] Long-term outcome of implantable cardioverter-defibrillator implantation in secondary prevention of sudden cardiac death
    Boule, Stephane
    Semichon, Marc
    Guedon-Moreau, Laurence
    Drumez, Elodie
    Kouakam, Claude
    Marquie, Christelle
    Brigadeau, Francois
    Kacet, Salem
    Potelle, Charlotte
    Escande, William
    Souissi, Zouheir
    Lacroix, Dominique
    Duhamel, Alain
    Klug, Didier
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2016, 109 (10) : 517 - 526
  • [43] Incidence of arrhythmic events in patients with implantable cardioverter-defibrillator for primary and secondary prevention of sudden cardiac death
    Capoferri, M
    Schwick, N
    Tanner, H
    Fuhrer, J
    Delacretaz, E
    SWISS MEDICAL WEEKLY, 2004, 134 (11-12) : 154 - 158
  • [44] The subcutaneous implantable cardioverter-defibrillator: A tertiary center experience
    Khazen, Cesar
    Magnusson, Peter
    Flandorfer, Johannes
    Schukro, Christoph
    CARDIOLOGY JOURNAL, 2019, 26 (05) : 543 - 549
  • [45] Implantable Cardioverter-Defibrillator therapy for primary prevention of sudden cardiac death in patients with severe Chagas cardiomyopathy
    Cardinalli-Neto, Augusto
    Nakazone, Marcelo A.
    Grassi, Luciano V.
    Tavares, Bruno G.
    Bestetti, Reinaldo B.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 150 (01) : 94 - 95
  • [46] PRIMARY AND SECONDARY PREVENTION OF SUDDEN CARDIAC DEATH IN ANDERSEN-TAWIL SYNDROME WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    Garcia, Alan
    Emmanuel Reyes-Quintero, Alvaro
    Morales Velazquez, Jose Luis
    Rafael Gomez, Jorge
    Marquez Murillo, Manlio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 389 - 389
  • [47] Prevention of sudden cardiac death: from wearable to subcutaneous cardioverter defibrillator
    Viani, Stefano
    Soldati, Ezio
    Di Cori, Andrea
    Segreti, Luca
    Paperini, Luca
    De Lucia, Raffaele
    Zuccheli, Giulio
    Bongiorni, Maria G.
    MINERVA CARDIOANGIOLOGICA, 2018, 66 (01): : 83 - 99
  • [48] Efficacy and Safety of Celivarone, With Amiodarone as Calibrator, in Patients With an Implantable Cardioverter-Defibrillator for Prevention of Implantable Cardioverter-Defibrillator Interventions or Death The ALPHEE Study
    Kowey, Peter R.
    Crijns, Harry J. G. M.
    Aliot, Etienne M.
    Capucci, Alessandro
    Kulakowski, Piotr
    Radzik, David
    Roy, Denis
    Connolly, Stuart J.
    Hohnloser, Stefan H.
    CIRCULATION, 2011, 124 (24) : 2649 - U204
  • [49] SHOCK WITHOUT WIRES: A LOOK AT SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR COMPARED TO TRANSVENOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR FOR VENTRICULAR ARRHYTHMIAS
    Guice, K. C.
    Raja, J.
    Oberoi, M.
    Khouzam, R.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2021, 69 (02) : 493 - 493
  • [50] Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator
    Bardy, GH
    Yee, R
    Jung, W
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (02) : 400 - 410