Shock Efficacy of Subcutaneous Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death Initial Multicenter Experience

被引:58
|
作者
Aydin, Ali [1 ]
Hartel, Friederike [1 ]
Schlueter, Michael [1 ]
Butter, Christian [3 ]
Koebe, Julia [4 ,5 ]
Seifert, Martin [3 ]
Gosau, Nils [1 ]
Hoffmann, Boris [1 ]
Hoffmann, Matthias [1 ]
Vettorazzi, Eik [6 ]
Wilke, Iris [1 ]
Wegscheider, Karl [6 ]
Reichenspurner, Hermann [2 ]
Eckardt, Lars [4 ,5 ]
Steven, Daniel [1 ]
Willems, Stephan [1 ]
机构
[1] Univ Heart Ctr, Dept Electrophysiol, Hamburg, Germany
[2] Univ Heart Ctr, Dept Cardiac Surg, Hamburg, Germany
[3] Heart Ctr Brandenburg Bernau, Dept Cardiol, Berlin, Germany
[4] Hosp Westfal Wilhelms Univ, Dept Cardiol, Div Expt & Clin Electrophysiol, Munster, Germany
[5] Hosp Westfal Wilhelms Univ, Dept Angiol, Div Expt & Clin Electrophysiol, Munster, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Med Biometry & Epidemiol, Ctr Med Expt, D-20246 Hamburg, Germany
来源
关键词
implantable cardioverter-defibrillator; ventricular tachyarrhythmia; implantable cardioverter-defibrillator shock failure; defibrillation threshold; subcutaneous implantable cardioverter-defibrillator; CLINICAL-EXPERIENCE; ICD THERAPY; MANAGEMENT;
D O I
10.1161/CIRCEP.112.973339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Recently, subcutaneous implantable cardioverter-defibrillator (S-ICD) has become available. The aim of our study was to assess the efficacy of S-ICD in a clinical setting. Methods and Results-Between June 2010 and July 2011, 40 consecutive patients (42 +/- 15 years; body mass index, 27 +/- 6 kg/m(2); left ventricular ejection fraction, 47 +/- 15%; 28 men) received an S-ICD for primary (n=17) or secondary prevention (n=23 [58%]) at 3 institutions in Germany. Intraoperative defibrillation efficacy testing failed in 1 patient with severely reduced left ventricular ejection fraction; testing was effective in all other patients. All episodes stored in the S-ICD were analyzed for appropriate and inappropriate detection, as well as effective shock delivery to convert ventricular tachyarrhythmia into sinus rhythm. During a median follow-up of 229 (interquartile range, 116-305) days, 4 patients experienced 21 episodes, with correct detection of ventricular tachyarrhythmia and subsequent shock therapy. A total of 28 shocks were delivered in these 4 patients. Mixed logistic regression modeling revealed a shock efficacy of 96.4% (95% CI, 12.8%-100%). The efficacy of first shocks, however, was only 57.9% (95% CI, 35.6%-77.4%). Four episodes were incorrectly classified as ventricular tachyarrhythmia, which led to inappropriate shock delivery in 2 patients. Conclusions-Ineffective shock delivery may occur in patients with S-ICD, even after successful intraoperative testing. Multicenter trials are required with close monitoring of safety and efficacy end points to identify patients who may be at risk for shock failure. (Circ Arrhythm Electrophysiol. 2012;5:913-919.)
引用
收藏
页码:913 / 919
页数:7
相关论文
共 50 条
  • [31] Clinical and anamnestic features of patients with implantable cardioverter-defibrillator for primary prevention of sudden cardiac death
    Talibullin, I.
    Lebedeva, N. Nataliya
    EUROPEAN JOURNAL OF HEART FAILURE, 2021, 23 : 6 - 7
  • [32] Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death
    Madhavan, Malini
    Waks, Jonathan W.
    Friedman, Paul A.
    Kramer, Daniel B.
    Buxton, Alfred E.
    Noseworthy, Peter A.
    Mehta, Ramila A.
    Hodge, David O.
    Higgins, Angela Y.
    Webster, Tracy L.
    Witt, Chance M.
    Cha, Yong-Mei
    Gersh, Bernard J.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (03):
  • [33] Subcutaneous implantable cardioverter defibrillator for the prevention of sudden cardiac death: ready for prime-time?
    Goldenberg, Llan
    Huang, David T.
    EUROPEAN HEART JOURNAL, 2022, 43 (47) : 4884 - 4886
  • [34] Development and external validation of prediction models to predict implantable cardioverter-defibrillator efficacy in primary prevention of sudden cardiac death
    Verstraelen, Tom E.
    van Barreveld, Marit
    van Dessel, Pascal H. F. M.
    Boersma, Lucas V. A.
    Delnoy, Peter-Paul P. H. M.
    Tuinenburg, Anton E.
    Theuns, Dominic A. M. J.
    van der Voort, Pepijn H.
    Kimman, Gerardus P.
    Buskens, Erik
    Hulleman, Michiel
    Allaart, Cornelis P.
    Strikwerda, Sipke
    Scholten, Marcoen F.
    Meine, Mathias
    Abels, Rene
    Maass, Alexander H.
    Firouzi, Mehran
    Widdershoven, Jos W. M. G.
    Elders, Jan
    van Gent, Marco W. F.
    Khan, Muchtiar
    Vernooy, Kevin
    Grauss, Robert W.
    Tukkie, Raymond
    van Erven, Lieselot
    Spierenburg, Han A. M.
    Brouwer, Marc A.
    Bartels, Gerard L.
    Bijsterveld, Nick R.
    van der Burg, Alida E. Borger
    Vet, Mattheus W.
    Derksen, Richard
    Knops, Reinoud E.
    Bracke, Frank A. L. E.
    Harden, Markus
    Sticherling, Christian
    Willems, Rik
    Friede, Tim
    Zabel, Markus
    Dijkgraaf, Marcel G. W.
    Zwinderman, Aeilko H.
    Wilde, Arthur A. M.
    EUROPACE, 2021, 23 (06): : 887 - 897
  • [35] The subcutaneous implantable cardioverter-defibrillator
    Grace, Andrew
    CURRENT OPINION IN CARDIOLOGY, 2014, 29 (01) : 10 - 19
  • [36] Subcutaneous Implantable Cardioverter-Defibrillator Lead Extraction First Multicenter French Experience
    Behar, Nathalie
    Galand, Vincent
    Martins, Raphael P.
    Jacon, Peggy
    Badenco, Nicolas
    Blangy, Hugues
    Alonso, Christine
    Guy-Moyat, Benoit
    El Bouazzaoui, Rim
    Lebon, Alain
    Giraudeau, Cedric
    Marquie, Christelle
    Leclercq, Christophe
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (07) : 863 - 870
  • [37] Initial experience with an implantable cardioverter-defibrillator incorporating cardiac resynchronization therapy
    Kühlkamp, V
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 790 - 797
  • [38] Acute shock efficacy of the subcutaneous implantable cardioverter-defibrillator according to the implantation technique
    Francia, Pietro
    Adduci, Carmen
    Angeletti, Andrea
    Ottaviano, Luca
    Perrotta, Laura
    De Vivo, Stefano
    Bongiorni, Maria Grazia
    Migliore, Federico
    Dello Russo, Antonio
    De Filippo, Paolo
    Caravati, Fabrizio
    Nigro, Gerardo
    Palmisano, Pietro
    Viani, Stefano
    D'Onofrio, Antonio
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Ziacchi, Matteo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (06) : 1695 - 1703
  • [39] Primary prevention of sudden cardiac death through a wearable cardioverter-defibrillator
    Gabrielli, Domenico
    Benvenuto, Manuela
    Baroni, Matteo
    Oliva, Fabrizio
    Capucci, Alessandro
    GIORNALE ITALIANO DI CARDIOLOGIA, 2015, 16 (07) : 418 - 425
  • [40] ROLE OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IN THE PREVENTION OF SUDDEN CARDIAC DEATH
    CAPUCCI, A
    BORIANI, G
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (01): : 1 - 4