Shock Efficacy of Subcutaneous Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death Initial Multicenter Experience

被引:58
|
作者
Aydin, Ali [1 ]
Hartel, Friederike [1 ]
Schlueter, Michael [1 ]
Butter, Christian [3 ]
Koebe, Julia [4 ,5 ]
Seifert, Martin [3 ]
Gosau, Nils [1 ]
Hoffmann, Boris [1 ]
Hoffmann, Matthias [1 ]
Vettorazzi, Eik [6 ]
Wilke, Iris [1 ]
Wegscheider, Karl [6 ]
Reichenspurner, Hermann [2 ]
Eckardt, Lars [4 ,5 ]
Steven, Daniel [1 ]
Willems, Stephan [1 ]
机构
[1] Univ Heart Ctr, Dept Electrophysiol, Hamburg, Germany
[2] Univ Heart Ctr, Dept Cardiac Surg, Hamburg, Germany
[3] Heart Ctr Brandenburg Bernau, Dept Cardiol, Berlin, Germany
[4] Hosp Westfal Wilhelms Univ, Dept Cardiol, Div Expt & Clin Electrophysiol, Munster, Germany
[5] Hosp Westfal Wilhelms Univ, Dept Angiol, Div Expt & Clin Electrophysiol, Munster, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Med Biometry & Epidemiol, Ctr Med Expt, D-20246 Hamburg, Germany
来源
关键词
implantable cardioverter-defibrillator; ventricular tachyarrhythmia; implantable cardioverter-defibrillator shock failure; defibrillation threshold; subcutaneous implantable cardioverter-defibrillator; CLINICAL-EXPERIENCE; ICD THERAPY; MANAGEMENT;
D O I
10.1161/CIRCEP.112.973339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Recently, subcutaneous implantable cardioverter-defibrillator (S-ICD) has become available. The aim of our study was to assess the efficacy of S-ICD in a clinical setting. Methods and Results-Between June 2010 and July 2011, 40 consecutive patients (42 +/- 15 years; body mass index, 27 +/- 6 kg/m(2); left ventricular ejection fraction, 47 +/- 15%; 28 men) received an S-ICD for primary (n=17) or secondary prevention (n=23 [58%]) at 3 institutions in Germany. Intraoperative defibrillation efficacy testing failed in 1 patient with severely reduced left ventricular ejection fraction; testing was effective in all other patients. All episodes stored in the S-ICD were analyzed for appropriate and inappropriate detection, as well as effective shock delivery to convert ventricular tachyarrhythmia into sinus rhythm. During a median follow-up of 229 (interquartile range, 116-305) days, 4 patients experienced 21 episodes, with correct detection of ventricular tachyarrhythmia and subsequent shock therapy. A total of 28 shocks were delivered in these 4 patients. Mixed logistic regression modeling revealed a shock efficacy of 96.4% (95% CI, 12.8%-100%). The efficacy of first shocks, however, was only 57.9% (95% CI, 35.6%-77.4%). Four episodes were incorrectly classified as ventricular tachyarrhythmia, which led to inappropriate shock delivery in 2 patients. Conclusions-Ineffective shock delivery may occur in patients with S-ICD, even after successful intraoperative testing. Multicenter trials are required with close monitoring of safety and efficacy end points to identify patients who may be at risk for shock failure. (Circ Arrhythm Electrophysiol. 2012;5:913-919.)
引用
收藏
页码:913 / 919
页数:7
相关论文
共 50 条
  • [21] Prevention of Sudden Cardiac Death with the Implantable Cardioverter-defibrillator in Children and Adolescents with Hypertrophic Cardiomyopathy: An International Multicenter Study
    Maron, Barry
    Spirito, Paolo
    Ackerman, Michael
    Casey, Susan
    Semsarian, Christopher
    Estes, N. A. Mark
    Day, Sharlene
    Formisano, Francesco
    Bos, J. Martijn
    Maron, Martin
    Link, Mark
    CIRCULATION, 2012, 126 (21)
  • [22] Gender Differences in Implantable Cardioverter-Defibrillator Utilization for Primary Prevention of Sudden Cardiac Death
    Dahiya, Garima
    Chen, Jane
    CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE, 2021, 23 (12)
  • [23] Multicenter Experience of Subcutaneous Implantable Cardioverter-Defibrillator Therapy in Patients With Dextrocardia
    Lueker, Jakob
    Padala, Santosh K.
    Cano, Oscar
    Beiert, Thomas
    Osswald, Brigitte
    Koneru, Jayanthi N.
    Schrickel, Jan W.
    Kron, Jordana
    Franqui-Rivera, Hilton
    Gonzalez-Cordero, Ariel
    Al-Ghamdi, Bandar S.
    Roberts, Paul R.
    Ceresnak, Scott R.
    von Alvensleben, Johannes
    Sultan, Arian
    Steven, Daniel
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (10) : 1226 - 1228
  • [24] Secondary prevention of sudden arrhythmic death: The role of the implantable cardioverter-defibrillator
    Esperer H.D.
    Klein H.
    Herzschrittmachertherapie und Elektrophysiologie, 2001, 12 (1): : 34 - 38
  • [25] Wearable cardioverter-defibrillator for prevention of sudden cardiac death after infected implantable cardioverter-defibrillator removal: A cost-effectiveness evaluation
    Healy, Christopher A.
    Carrillo, Roger G.
    HEART RHYTHM, 2015, 12 (07) : 1565 - 1573
  • [26] Implantable cardioverter-defibrillator therapy and the total burden of sudden cardiac death
    Huikuri, Heikki V.
    EUROPACE, 2009, 11 (12): : 1574 - 1574
  • [28] Predictors of appropriate therapy in patients with implantable cardioverter-defibrillator for primary prevention of sudden cardiac death
    Ahmed, Imdad
    Nelson, William B.
    House, Chad M.
    Zhu, Dennis W. X.
    HEART INTERNATIONAL, 2010, 5 (01): : 16 - 19
  • [29] Sex Differences in Outcomes of Patients with an Implantable Cardioverter-Defibrillator for the Secondary Prevention of Sudden Cardiac Death
    Noordman, Alwin B. P.
    Rienstra, Michiel
    Blaauw, Yuri
    Mulder, Bart A.
    Maass, Alexander H.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (04)
  • [30] Assessing the benefit of a replacement implantable cardioverter-defibrillator device for primary prevention of sudden cardiac death
    Auricchio, A.
    Curtis, A. B.
    Mittal, S.
    Pickett, R. A.
    Jacobsen, L.
    Lande, J. D.
    Wilkoff, B. L.
    EUROPEAN HEART JOURNAL, 2023, 44