Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models

被引:53
|
作者
Tian, Xiaoyu [1 ]
Li, Xiang [1 ]
Segars, W. Paul [1 ]
Paulson, Erik K. [1 ]
Frush, Donald P. [1 ]
Samei, Ehsan [1 ]
机构
[1] Duke Univ, Dept Radiol, Durham, NC 27705 USA
关键词
CANCER-RISK ESTIMATION; MONTE-CARLO; RADIATION-EXPOSURE; SCANS; FEASIBILITY; VALIDATION; SIMULATION;
D O I
10.1148/radiol.13122617
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods: The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results: For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R-2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. Conclusion: It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. (C) RSNA, 2013
引用
收藏
页码:535 / 547
页数:13
相关论文
共 50 条
  • [21] Patient effective dose and radiation biological risk in the chest and abdominopelvic computed tomography
    Jamshidi, Mohammad Hossein
    Karami, Aida
    Salimi, Yazdan
    Keshavarz, Amirhesam
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [22] Estimation of organ absorbed dose in pediatric chest X-ray examination: A phantom study
    Jamal, Nurul H. M.
    Sayed, Inayatullah S.
    Syed, Waliullah S.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [23] Patient organ and effective dose estimation in CT: comparison of four software applications
    De Mattia, Cristina
    Campanaro, Federica
    Rottoli, Federica
    Colombo, Paola Enrica
    Pola, Andrea
    Vanzulli, Angelo
    Torresin, Alberto
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [24] Patient organ and effective dose estimation in CT: comparison of four software applications
    Cristina De Mattia
    Federica Campanaro
    Federica Rottoli
    Paola Enrica Colombo
    Andrea Pola
    Angelo Vanzulli
    Alberto Torresin
    European Radiology Experimental, 4
  • [25] Organ Dose Estimation for Adult Chest CT Examination Using GATE Monte Carlo Simulation
    M. Tahiri
    M. Mkimel
    Y. Benameur
    R. El Baydaoui
    M. R. Mesradi
    O. El Rhazouani
    Physics of Particles and Nuclei Letters, 2021, 18 : 502 - 509
  • [26] Organ Dose Estimation for Adult Chest CT Examination Using GATE Monte Carlo Simulation
    Tahiri, M.
    Mkimel, M.
    Benameur, Y.
    El Baydaoui, R.
    Mesradi, M. R.
    El Rhazouani, O.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2021, 18 (04) : 502 - 509
  • [27] Organ Dose Estimation Accuracy Using a Modified SSDE for CT Examination in a Pediatric Population
    Deaton, N.
    Kaufman, R.
    Somasundarum, E.
    Brady, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 3316 - 3317
  • [28] Simulation Study of Patient Off-Centering Effect On Organ Dose in Chest CT Scan
    Gao, Y.
    Lin, H.
    Liu, T.
    Li, X.
    Liu, B.
    Khawaja, R.
    Kalra, M.
    Caracappa, P.
    Xu, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3544 - 3544
  • [29] Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT—phantom study
    Touko Kaasalainen
    Kirsi Palmu
    Anniina Lampinen
    Mika Kortesniemi
    Pediatric Radiology, 2013, 43 : 673 - 684
  • [30] Organ Dose Estimation for CT Localizer Images
    Hoye, J.
    Zhang, Y.
    Fu, W.
    Abadi, E.
    Ria, F.
    Kapadia, A.
    Segars, P.
    Samei, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3301 - 3301