Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models

被引:53
|
作者
Tian, Xiaoyu [1 ]
Li, Xiang [1 ]
Segars, W. Paul [1 ]
Paulson, Erik K. [1 ]
Frush, Donald P. [1 ]
Samei, Ehsan [1 ]
机构
[1] Duke Univ, Dept Radiol, Durham, NC 27705 USA
关键词
CANCER-RISK ESTIMATION; MONTE-CARLO; RADIATION-EXPOSURE; SCANS; FEASIBILITY; VALIDATION; SIMULATION;
D O I
10.1148/radiol.13122617
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods: The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results: For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R-2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. Conclusion: It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. (C) RSNA, 2013
引用
收藏
页码:535 / 547
页数:13
相关论文
共 50 条
  • [41] Convolution-based estimation of organ dose in tube current modulated CT
    Tian, Xiaoyu
    Segars, W. Paul
    Dixon, Robert L.
    Samei, Ehsan
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (10): : 3935 - 3954
  • [42] Uncertainties in Convolution-Based Organ Dose Estimation in TubeCurrent Modulated CT
    Fu, W.
    Choudhury, K.
    Kapadia, A.
    Segars, P.
    Samei, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3301 - 3301
  • [43] Convolution-based Estimation of Organ Dose in Tube Current Modulated CT
    Tian, Xiaoyu
    Segars, W. Paul
    Dixon, R. L.
    Samei, Ehsan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [44] Local diagnostic reference levels of pediatric chest and abdominopelvic CT examinations based on body weight in central region of Saudi Arabia
    Alenazi, Khaled
    Alkhybari, Essam
    Alhailiy, Ali
    Alahmad, Haitham
    Alghamdi, Sultan
    Fisal, Nada
    Albeshan, Salman
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2025, 18 (02)
  • [45] Evaluation of a Radiation Dose Reduction Strategy for Pediatric Chest CT
    Kim, Jee-Eun
    Newman, Beverley
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : 1188 - 1193
  • [46] Effect of Patient Centering on Patient Dose and Image Noise in Chest CT
    Kaasalainen, Touko
    Palmu, Kirsi
    Reijonen, Vappu
    Kortesniemi, Mika
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (01) : 123 - 130
  • [47] Low dose multislice CT in the pediatric patient
    Hojreh, A
    Kainberger, F
    Puig, S
    RADIOLOGE, 2003, 43 (12): : 1051 - 1055
  • [48] CT dose reduction strategies and the pediatric patient
    Cody, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1834 - 1834
  • [49] CT dose reduction strategies and the pediatric patient
    Cody, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1441 - 1441
  • [50] Analysis of Uncertainties in Monte Carlo Simulated Organ Dose for Chest CT
    Muryn, John S.
    Morgan, Ashraf G.
    Segars, W. Paul
    Liptak, Chris L.
    Dong, Frank F.
    Primak, Andrew N.
    Li, Xiang
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412