Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models

被引:53
|
作者
Tian, Xiaoyu [1 ]
Li, Xiang [1 ]
Segars, W. Paul [1 ]
Paulson, Erik K. [1 ]
Frush, Donald P. [1 ]
Samei, Ehsan [1 ]
机构
[1] Duke Univ, Dept Radiol, Durham, NC 27705 USA
关键词
CANCER-RISK ESTIMATION; MONTE-CARLO; RADIATION-EXPOSURE; SCANS; FEASIBILITY; VALIDATION; SIMULATION;
D O I
10.1148/radiol.13122617
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods: The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results: For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R-2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. Conclusion: It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. (C) RSNA, 2013
引用
收藏
页码:535 / 547
页数:13
相关论文
共 50 条
  • [1] Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models
    Tian, Xiaoyu
    Li, Xiang
    Segars, W. Paul
    Frush, Donald P.
    Paulson, Erik K.
    Samei, Ehsan
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (24): : 8755 - 8768
  • [2] Patient-specific dose estimation for pediatric chest CT
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    MEDICAL PHYSICS, 2008, 35 (12) : 5821 - 5828
  • [3] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Franck, Caro
    Vandevoorde, Charlot
    Goethals, Ingeborg
    Smeets, Peter
    Achten, Eric
    Verstraete, Koenraad
    Thierens, Hubert
    Bacher, Klaus
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2646 - 2655
  • [4] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Caro Franck
    Charlot Vandevoorde
    Ingeborg Goethals
    Peter Smeets
    Eric Achten
    Koenraad Verstraete
    Hubert Thierens
    Klaus Bacher
    European Radiology, 2016, 26 : 2646 - 2655
  • [5] Organ Dose Heterogeneity in Chest and Abdominopelvic CT Scans for a Population of Adult and Pediatric Phantoms: A Virtual Clinical Trial Study
    Fenoli, J.
    Sharma, S.
    Abadi, E.
    Segars, P.
    Samei, E.
    Kapadia, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E153 - E153
  • [6] Estimation of effective and organ dose from chest CT
    Almaasfeh, Sultan
    Salahudeen, Abdulrahman
    Salih, Mohammed
    Abukonna, Ahmed
    RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [7] Organ Dose in Chest CT: Effect of Modulation Scheme on Estimation Accuracy
    Li, Xiang
    Segars, W. Paul
    Samei, Ehsan
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [8] MEASUREMENT OF ENTRANCE SKIN DOSE AND ESTIMATION OF ORGAN DOSE DURING PEDIATRIC CHEST RADIOGRAPHY
    Kumaresan, M.
    Kumar, Rajesh
    Biju, K.
    Choubey, Ajay
    Kantharia, S.
    HEALTH PHYSICS, 2011, 100 (06): : 654 - 657
  • [9] A comparison of pediatric and adult CT organ dose estimation methods
    Yiming Gao
    Brian Quinn
    Usman Mahmood
    Daniel Long
    Yusuf Erdi
    Jean St. Germain
    Neeta Pandit-Taskar
    X. George Xu
    Wesley E. Bolch
    Lawrence T. Dauer
    BMC Medical Imaging, 17
  • [10] A comparison of pediatric and adult CT organ dose estimation methods
    Gao, Yiming
    Quinn, Brian
    Mahmood, Usman
    Long, Daniel
    Erdi, Yusuf
    Germain, Jean St.
    Pandit-Taskar, Neeta
    Xu, X. George
    Bolch, Wesley E.
    Dauer, Lawrence T.
    BMC MEDICAL IMAGING, 2017, 17