Improved Automated Detection of Diabetic Retinopathy on a Publicly Available Dataset Through Integration of Deep Learning

被引:684
|
作者
Abramoff, Michael David [1 ,2 ,3 ]
Lou, Yiyue [4 ]
Erginay, Ali [5 ]
Clarida, Warren [3 ]
Amelon, Ryan [3 ]
Folk, James C. [1 ,3 ]
Niemeijer, Meindert [3 ]
机构
[1] Univ Iowa, Hosp & Clin, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[2] Iowa City Vet Affairs Med Ctr, Iowa City, IA USA
[3] IDx LLC, Iowa City, IA USA
[4] Univ Iowa, Dept Stat, Coll Publ Hlth, Iowa City, IA USA
[5] Hop Lariboisiere, AP HP, Serv Ophtalmol, Paris, France
关键词
diabetic retinopathy; detection; deep learning; algorithm; diabetes; MACULAR EDEMA; SCREENING EXAMINATIONS; IMAGE-ANALYSIS; TELEMEDICINE; PHOTOGRAPHY;
D O I
10.1167/iovs.16-19964
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare performance of a deep-learning enhanced algorithm for automated detection of diabetic retinopathy (DR), to the previously published performance of that algorithm, the Iowa Detection Program (IDP)-without deep learning components-on the same publicly available set of fundus images and previously reported consensus reference standard set, by three US Board certified retinal specialists. METHODS. We used the previously reported consensus reference standard of referable DR (rDR), defined as International Clinical Classification of Diabetic Retinopathy moderate, severe nonproliferative (NPDR), proliferative DR, and/or macular edema (ME). Neither Messidor-2 images, nor the three retinal specialists setting the Messidor-2 reference standard were used for training IDx-DR version X2.1. Sensitivity, specificity, negative predictive value, area under the curve (AUC), and their confidence intervals (CIs) were calculated. RESULTS. Sensitivity was 96.8% (95% CI: 93.3%-98.8%), specificity was 87.0% (95% CI: 84.2%-89.4%), with 6/874 false negatives, resulting in a negative predictive value of 99.0% (95% CI: 97.8%-99.6%). No cases of severe NPDR, PDR, or ME were missed. The AUC was 0.980 (95% CI: 0.968-0.992). Sensitivity was not statistically different from published IDP sensitivity, which had a CI of 94.4% to 99.3%, but specificity was significantly better than the published IDP specificity CI of 55.7% to 63.0%. CONCLUSIONS. A deep-learning enhanced algorithm for the automated detection of DR, achieves significantly better performance than a previously reported, otherwise essentially identical, algorithm that does not employ deep learning. Deep learning enhanced algorithms have the potential to improve the efficiency of DR screening, and thereby to prevent visual loss and blindness from this devastating disease.
引用
收藏
页码:5200 / 5206
页数:7
相关论文
共 50 条
  • [21] Deep Learning Approach to Diabetic Retinopathy Detection
    Tymchenko, Borys
    Marchenko, Philip
    Spodarets, Dmitry
    ICPRAM: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION APPLICATIONS AND METHODS, 2020, : 501 - 509
  • [22] A Deep Learning Approach for the Diabetic Retinopathy Detection
    Sebti, Riad
    Zroug, Siham
    Kahloul, Laid
    Benharzallah, Saber
    6TH INTERNATIONAL CONFERENCE ON SMART CITY APPLICATIONS, 2022, 393 : 459 - 469
  • [23] A Deep Learning Method for the detection of Diabetic Retinopathy
    Chakrabarty, Navoneel
    2018 5TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING (UPCON), 2018, : 13 - 17
  • [24] Clinical Validation of a Deep Learning Automated Algorithm for the Detection of Diabetic Retinopathy and Macular Edema
    Stebbins, Kristen
    Wang, Ynjiun
    Tang, Lilian
    Suri, Naren
    Wang, Su
    Purohit, Amish
    Johnson, Max
    Chaum, Edward
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [25] Nonproliferative diabetic retinopathy dataset(NDRD): A database for diabetic retinopathy screening research and deep learning evaluation
    Liang, Xing
    Wen, Haiqi
    Duan, Yajian
    He, Kan
    Feng, Xiufang
    Zhou, Guohong
    HEALTH INFORMATICS JOURNAL, 2024, 30 (02)
  • [26] Transfer Learning for Automated OCTA Detection of Diabetic Retinopathy
    Le, David
    Alam, Minhaj
    Yao, Cham K.
    Lim, Jennifer, I
    Hsieh, Yi-Ting
    Chan, Robison V. P.
    Toslak, Devrim
    Yao, Xincheng
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (02): : 1 - 9
  • [27] XCapsNet: A deep neural network for automated detection of diabetic retinopathy
    Gour, Mahesh
    Jain, Sweta
    Kaushal, Sushant
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2023, 33 (03) : 1014 - 1027
  • [28] Automated detection of diabetic retinopathy using convolutional neural networks on a small dataset
    Samanta, Abhishek
    Saha, Aheli
    Satapathy, Suresh Chandra
    Fernandes, Steven Lawrence
    Zhang, Yu-Dong
    PATTERN RECOGNITION LETTERS, 2020, 135 : 293 - 298
  • [29] The SUSTech-SYSU dataset for automated exudate detection and diabetic retinopathy grading
    Lin, Li
    Li, Meng
    Huang, Yijin
    Cheng, Pujin
    Xia, Honghui
    Wang, Kai
    Yuan, Jin
    Tang, Xiaoying
    SCIENTIFIC DATA, 2020, 7 (01)
  • [30] The SUSTech-SYSU dataset for automated exudate detection and diabetic retinopathy grading
    Li Lin
    Meng Li
    Yijin Huang
    Pujin Cheng
    Honghui Xia
    Kai Wang
    Jin Yuan
    Xiaoying Tang
    Scientific Data, 7