Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity

被引:285
|
作者
Cheng, HLM
Wright, GA
机构
[1] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Res Inst, Toronto, ON M5G 1X8, Canada
[3] Hosp Sick Children, Dept Med Imaging, Toronto, ON, Canada
[4] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
T-1; mapping; fast volumetric imaging; high-field MRI; quantitative MRI;
D O I
10.1002/mrm.20791
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rapid 3D mapping of T-1 relaxation times is valuable in diverse clinical applications. Recently, the variable flip angle (VFA) spoiled gradient recalled echo approach was shown to be a practical alternative to conventional methods, providing better precision and speed. However, the method is known to be sensitive to transmit field (B-1(+)) inhomogeneity and can result in significant systematic errors in T-1 estimates, especially at high field strengths. The main challenge is to improve the accuracy of the VFA approach without sacrificing speed. In this article, the VFA method was optimized for both accuracy and precision by considering the influence of imperfect transmit fields, noise bias, and selection of flip angles. An analytic solution was developed for systematic B-1(+)-induced T-1 errors and allows simple correction of T-1 measurements acquired with any imaging parameters. A noise threshold was also identified and provided a guideline for avoiding T-1 biases. Finally, it was shown that three flip angles were the most efficient for maintaining accuracy and high precision over large ranges of T-1. A rapid B-1(+) mapping sequence was employed in all phantom experiments and high-field in vivo brain scans. Experimental results confirmed the theory and validated the accuracy of the proposed method.
引用
收藏
页码:566 / 574
页数:9
相关论文
共 50 条
  • [1] Rapid 2D variable flip angle method for accurate and precise T1 measurements over a wide range of T1 values
    Lena, Beatrice
    Bos, Clemens
    Ferrer, Cyril J.
    Moonen, Chrit T. W.
    Viergever, Max A.
    Bartels, Lambertus W.
    NMR IN BIOMEDICINE, 2021, 34 (08)
  • [2] Bias, Repeatability and Reproducibility of Liver T1 Mapping With Variable Flip Angles
    Tadimalla, Sirisha
    Wilson, Daniel J.
    Shelley, David
    Bainbridge, Gavin
    Saysell, Margaret
    Mendichovszky, Iosif A.
    Graves, Martin J.
    Guthrie, J. Ashley
    Waterton, John C.
    Parker, Geoffrey J. M.
    Sourbron, Steven P.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (04) : 1042 - 1052
  • [3] Uncertainty in T1 mapping using the variable flip angle method with two flip angles
    Schabel, Matthias C.
    Morrell, Glen R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01): : N1 - N8
  • [4] Editorial for "Bias, Repeatability and Reproducibility of Liver T1 Mapping With Variable Flip Angles"
    Tamada, Daiki
    Reeder, Scott B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (04) : 1053 - 1054
  • [5] Fast high-resolution T1 mapping of the human brain
    Deichmann, R
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 20 - 27
  • [6] Simultaneous T1 measurements and proton resonance frequency shift based thermometry using variable flip angles
    Hey, S.
    de Smet, M.
    Stehning, C.
    Grull, H.
    Keupp, J.
    Moonen, C. T. W.
    Ries, M.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 457 - 463
  • [7] The application of B1 inhomogeneity-corrected variable flip angle T1 mapping for assessing liver fibrosis
    Zou, Jie
    Jiang, Yanli
    Fan, Fengxian
    Yang, Pin
    Gan, Tiejun
    Yang, Tingli
    Li, Min
    Ding, Yuan
    Wang, Shaoyu
    Zhang, Jing
    MAGNETIC RESONANCE IMAGING, 2024, 113
  • [8] High-Resolution, Whole Heart T1 Mapping in a Chronic Atrial Fibrillation Model
    Khoimovski, Eugene G.
    Kim, Daniel
    Vijayakumar, Sathya
    Ranjan, Ravi
    Dosdall, Derek
    Higuchi, Koji
    MacLeod, Rob
    Marrouche, Nassir F.
    CIRCULATION, 2013, 128 (22)
  • [9] High-resolution T1 relaxation time mapping at 7 Tesla in multiple sclerosis
    de Graaf, W. L.
    Kilsdonk, I. D.
    Hoogduin, J. M.
    Polders, D. L.
    Visser, F.
    Vrenken, H.
    Polman, C. H.
    Barkhof, F.
    Luijten, P. R.
    Castelijns, J. A.
    Pouwels, P. J. W.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S376 - S376
  • [10] High-resolution three-dimensional ANGIE T1 mapping of the whole heart
    Bhairav B Mehta
    Michael Salerno
    Frederick H Epstein
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)