Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity

被引:285
|
作者
Cheng, HLM
Wright, GA
机构
[1] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Res Inst, Toronto, ON M5G 1X8, Canada
[3] Hosp Sick Children, Dept Med Imaging, Toronto, ON, Canada
[4] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
T-1; mapping; fast volumetric imaging; high-field MRI; quantitative MRI;
D O I
10.1002/mrm.20791
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rapid 3D mapping of T-1 relaxation times is valuable in diverse clinical applications. Recently, the variable flip angle (VFA) spoiled gradient recalled echo approach was shown to be a practical alternative to conventional methods, providing better precision and speed. However, the method is known to be sensitive to transmit field (B-1(+)) inhomogeneity and can result in significant systematic errors in T-1 estimates, especially at high field strengths. The main challenge is to improve the accuracy of the VFA approach without sacrificing speed. In this article, the VFA method was optimized for both accuracy and precision by considering the influence of imperfect transmit fields, noise bias, and selection of flip angles. An analytic solution was developed for systematic B-1(+)-induced T-1 errors and allows simple correction of T-1 measurements acquired with any imaging parameters. A noise threshold was also identified and provided a guideline for avoiding T-1 biases. Finally, it was shown that three flip angles were the most efficient for maintaining accuracy and high precision over large ranges of T-1. A rapid B-1(+) mapping sequence was employed in all phantom experiments and high-field in vivo brain scans. Experimental results confirmed the theory and validated the accuracy of the proposed method.
引用
收藏
页码:566 / 574
页数:9
相关论文
共 50 条
  • [31] High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2
    Deoni, SCL
    Peters, TM
    Rutt, BK
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) : 237 - 241
  • [32] Accelerated 3D free-breathing high-resolution myocardial T1ρ mapping at 3 Tesla
    Qi, Haikun
    Lv, Zhenfeng
    Hu, Junpu
    Xu, Jian
    Botnar, Rene
    Prieto, Claudia
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2520 - 2531
  • [33] Respiratory motion-compensated high-resolution 3D whole-heart T1ρ mapping
    Haikun Qi
    Aurelien Bustin
    Thomas Kuestner
    Reza Hajhosseiny
    Gastao Cruz
    Karl Kunze
    Radhouene Neji
    René M. Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 22
  • [34] Respiratory motion-compensated high-resolution 3D whole-heart T1ρ mapping
    Qi, Haikun
    Bustin, Aurelien
    Kuestner, Thomas
    Hajhosseiny, Reza
    Cruz, Gastao
    Kunze, Karl
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [35] High-Resolution 3-D T1*-Mapping and Quantitative Image Analysis of GRAY ZONE in Chronic Fibrosis
    Pop, Mihaela
    Ramanan, Venkat
    Yang, Franklin
    Zhang, Li
    Newbigging, Susan
    Ghugre, Nilesh R.
    Wright, Graham A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (12) : 2930 - 2938
  • [36] Quantitative T1 and proton density mapping with direct calculation of radiofrequency coil transmit and receive profiles from two-point variable flip angle data
    Baudrexel, Simon
    Reitz, Sarah C.
    Hof, Stephanie
    Gracien, Rene-Maxime
    Fleischer, Vinzenz
    Zimmermann, Hilga
    Droby, Amgad
    Klein, Johannes C.
    Deichmann, Ralf
    NMR IN BIOMEDICINE, 2016, 29 (03) : 349 - 360
  • [37] Role of contrast-enhanced magnetic resonance high-resolution variable flip angle turbo-spin-echo (T1 SPACE) technique in diagnosis of transverse sinus stenosis
    Quan, Tao
    Ren, Yanan
    Lin, Yanan
    Guan, Sheng
    Hou, Haiman
    Yan, Baojun
    Cheng, Jingliang
    Xu, Haowen
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 120
  • [38] Simultaneous high-resolution cardiac T1 mapping and cine imaging using model-based iterative image reconstruction
    Becker, Kirsten M.
    Schulz-Menger, Jeanette
    Schaeffter, Tobias
    Kolbitsch, Christoph
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1080 - 1091
  • [39] High-Resolution MRS in the Presence of Field Inhomogeneity via Intermolecular Double-Quantum Coherences on a 3-T Whole-Body Scanner
    Lin, Yanqin
    Gu, Tianliang
    Chen, Zhong
    Kennedy, Scott
    Jacob, Mathews
    Zhong, Jianhui
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 303 - 311
  • [40] Optimized inversion-time schedules for quantitative T1 measurements based on high-resolution multi-inversion EPI
    Cohen, Ouri
    Polimeni, Jonathan R.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2101 - 2112