Uncertainty in T1 mapping using the variable flip angle method with two flip angles

被引:80
|
作者
Schabel, Matthias C. [1 ]
Morrell, Glen R. [1 ]
机构
[1] Univ Utah, Hlth Sci Ctr, Utah Ctr Adv Imaging Res, Dept Radiol, Salt Lake City, UT 84108 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 01期
关键词
T1; ACQUISITION; ACCURATE; MRI;
D O I
10.1088/0031-9155/54/1/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Propagation of errors, in conjunction with the theoretical signal equation for spoiled gradient echo pulse sequences, is used to derive a theoretical expression for uncertainty in quantitative variable flip angle T-1 mapping using two flip angles. This expression is then minimized to derive a rigorous expression for optimal flip angles that elucidates a commonly used empirical result. The theoretical expressions for uncertainty and optimal flip angles are combined to derive a lower bound on the achievable uncertainty for a given set of pulse sequence parameters and signal-to-noise ratio (SNR). These results provide a means of quantitatively determining the effect of changing acquisition parameters on T-1 uncertainty.
引用
收藏
页码:N1 / N8
页数:8
相关论文
共 50 条
  • [1] T1 Mapping Using Variable Flip Angle SPGR Data With Flip Angle Correction
    Liberman, Gilad
    Louzoun, Yoram
    Ben Bashat, Dafna
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 171 - 180
  • [2] Silent T1 mapping using the variable flip angle method with B1 correction
    Ljungberg, Emil
    Wood, Tobias
    Solana, Ana Beatriz
    Kolind, Shannon
    Williams, Steven C. R.
    Wiesinger, Florian
    Barker, Gareth J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 813 - 824
  • [3] Bias, Repeatability and Reproducibility of Liver T1 Mapping With Variable Flip Angles
    Tadimalla, Sirisha
    Wilson, Daniel J.
    Shelley, David
    Bainbridge, Gavin
    Saysell, Margaret
    Mendichovszky, Iosif A.
    Graves, Martin J.
    Guthrie, J. Ashley
    Waterton, John C.
    Parker, Geoffrey J. M.
    Sourbron, Steven P.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (04) : 1042 - 1052
  • [4] Improved precision in SASHA T1 mapping with a variable flip angle readout
    Kelvin Chow
    Bruce S Spottiswoode
    Joseph J Pagano
    Richard B Thompson
    [J]. Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [5] Editorial for "Bias, Repeatability and Reproducibility of Liver T1 Mapping With Variable Flip Angles"
    Tamada, Daiki
    Reeder, Scott B.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (04) : 1053 - 1054
  • [6] Tissue sodium concentration and sodium T1 mapping of the human brain at 3 T using a Variable Flip Angle method
    Coste, Arthur
    Boumezbeur, Fawzi
    Vignaud, Alexandre
    Madelin, Guillaume
    Reetz, Kathrin
    Le Bihan, Denis
    Rabrait-Lerman, Cecile
    Romanzetti, Sandro
    [J]. MAGNETIC RESONANCE IMAGING, 2019, 58 : 116 - 124
  • [7] Assessment of Liver Fibrosis by Variable Flip Angle T1 Mapping at 3.0T
    Li, Zhiming
    Sun, Jihong
    Hu, Xi
    Huang, Ning
    Han, Guocan
    Chen, Lumin
    Zhou, Yurong
    Bai, Weixian
    Yang, Xiaoming
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (03) : 698 - 703
  • [8] Simultaneous T1 and B1+ Mapping Using Reference Region Variable Flip Angle Imaging
    Sung, Kyunghyun
    Saranathan, Manojkumar
    Daniel, Bruce L.
    Hargreaves, Brian A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 954 - 961
  • [9] 3D Myocardial T1 Mapping at 3T Using Variable Flip Angle Method: Pilot Study
    Clique, Helene
    Cheng, Hai-Ling Margaret
    Marie, Pierre-Yves
    Felblinger, Jacques
    Beaumont, Marine
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 823 - 829
  • [10] Spatially regularized T1 estimation from variable flip angles MRI
    Wang, Hesheng
    Cao, Yue
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4139 - 4148