The COCAE Detector: An instrument for localization - identification of radioactive sources

被引:0
|
作者
Lambropoulos, C. P. [1 ]
Aoki, T.
Crocco, J. [2 ]
Dieguez, E. [2 ]
Disch, C. [3 ]
Fauler, A. [3 ]
Fiederle, M. [3 ]
Hatzistratis, D. [1 ,4 ,9 ]
Gnatyuk, V. A.
Karafasoulis, K. [5 ]
Kosyachenko, L. A. [6 ]
Levytskyi, S. N. [7 ]
Loukas, D. [8 ]
Maslyanchuk, O. L. [6 ]
Medvids, A. [10 ]
Orphanoudakis, T. [1 ]
Papadakis, I. [9 ]
Papadimitriou, A. [9 ]
Papakonstantinou, K. [1 ,9 ]
Potiriadis, C.
Schulman, T.
Sklyarchuk, V. V. [6 ]
Spartiotis, K.
Theodoratos, G. [1 ,9 ]
Vlasenko, O. I.
Zachariadou, K.
Zervakis, E. [1 ]
机构
[1] Technol Educ Inst Chalkida, Psahna Evia 34400, Greece
[2] Univ Shizuoka, Dept Fis Mat, Shizuoka 4228526, Japan
[3] Univ Freiburg, Freiburg, Germany
[4] Technol Educ Inst Chalkida, Psahna Evia 34400, Greece
[5] Greek Atom Engy Commiss, Athens, Greece
[6] Univ KwaZulu Natal, Chernovtsy, Ukraine
[7] Natl Acad Sci, Inst Semicond Phys, Kiev, Ukraine
[8] Natl Ctr Scient Res, Athens, Greece
[9] Technol Educ Inst, Psahna Evia 34400, Greece
[10] Riga Tech Univ, Riga, Latvia
关键词
CDZNTE; CDTE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The COCAE project develops an instrument for localization and identification of radioactive sources. For the localization task it will exploit the Compton scattered photons within its detecting layers. It is based on pixilated Cd(Zn)Te matrices in a stacked configuration. Progress has been achieved in all the components necessary for this technology. CdZnTe crystals have been grown of up to 75mm in diameter. A wafer level pixelization process has been tested and its results will be presented. Very good energy resolution is necessary for the performance of the instrument. For this reason we have investigated planar M-p-n diodes fabricated by using laser-induced solid phase doping and Schottky diodes created by Arion etching of the Cd(Zn) Te surfaces before deposition of Ni electrodes. The energy resolution achieved is better than 1% FWHM @662KeV. The development of a pixel CMOS readout integrated circuit has been undertaken. It outputs in digital format address, energy and time information for the pixels which have collected charge above a given threshold. Simulation studies of the minimum detection limits, of the Compton sequencing algorithms, of the angular resolution and of the reconstruction of the radioactive source position have been performed. Experiments with a precursor setup using an existing hybrid detector are underway.
引用
收藏
页码:3910 / 3917
页数:8
相关论文
共 50 条
  • [21] Identification of interference sources with the help of a correlation detector
    Ral'nikov, V.I.
    Kharchenko, I.P.
    Elektrosvyaz, 2001, (09): : 6 - 7
  • [22] Performance tests of a silicon strip detector with radioactive sources and proton beam
    Kim, Y. I.
    Kang, Heedong
    Kim, H. J.
    Park, H.
    Ryu, S.
    Son, D. H.
    Kim, Kyeryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 828 - 831
  • [23] HPGe virtual point detector for radioactive volume-ring sources
    Nasrabadi, M. N.
    Kashi, S. H.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [24] Radioactive source localization employing resistive electrode array (REA) detector
    Hoegele, Wolfgang
    Zhang, Victoria
    Vasquez, Elena Grace
    Gineitaite, Indre
    Sajo, Erno
    Brivio, Davide
    Zygmanski, Piotr
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (02)
  • [25] Identification of high priority radioactive sources based on risk
    Paperiello, CJ
    Kosenko, V
    Burdukov, PT
    Arutyunyan, RV
    Kotzé, TC
    Codée, HDK
    Gryshchenko, K
    SECURITY OF RADIOACTIVE SOURCES, 2003, : 113 - 121
  • [26] UAV prototype for localization and identification of radioactive contamination and emitters
    Moretto, S.
    Andrades, F. E. Pino
    Delgado, J.
    Fontana, C. L.
    Fabris, D.
    Nebbia, G.
    Turcato, M.
    Brunelli, D.
    Pancheri, L.
    Quaranta, A.
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [27] NEW RADIOACTIVE GAS CHROMATOGRAPHIC DETECTOR FOR IDENTIFICATION OF STRONG OXIDANTS
    GUDZINOWIDZ, BJ
    SMITH, WR
    ANALYTICAL CHEMISTRY, 1963, 35 (04) : 465 - &
  • [28] Using a portable muon detector for radioactive source measurements and identification
    Masias, J.
    Delgado, F.
    Coll, L.
    Perez, A.
    Bazo, J.
    Gago, A. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 944
  • [29] Machine learning for localization of radioactive sources via a distributed sensor network
    Abdelhakim, Assem
    SOFT COMPUTING, 2023, 27 (15) : 10493 - 10508
  • [30] Machine learning for localization of radioactive sources via a distributed sensor network
    Assem Abdelhakim
    Soft Computing, 2023, 27 : 10493 - 10508