Using a portable muon detector for radioactive source measurements and identification

被引:1
|
作者
Masias, J. [1 ]
Delgado, F. [1 ]
Coll, L. [1 ]
Perez, A. [1 ]
Bazo, J. [1 ]
Gago, A. M. [1 ]
机构
[1] Pontificia Univ Catolica Peru, Secc Fis, Dept Ciencias, Av Univ 1801, Lima 32, Peru
关键词
Muon detector; Plastic scintillator; Geant4; Beta sources;
D O I
10.1016/j.nima.2019.162588
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have re-purposed portable plastic scintillator muon detectors, designed by the CosmicWatch project, for the measurement of electrons emitted by the decay of radioactive sources. For the latter purpose we have first calibrated the detectors using the local atmospheric muon flux, performing angular distribution and attenuation measurements. In addition, we have simulated the detector using Geant4 in a detailed fashion for a cross-check and better understanding of the device. Then, we have developed a method to evaluate the activity of beta-sources and to discriminate different beta-sources by looking into their respective voltage spectrum output.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Muon Identification using Neural Networks With the Muon Telescope Detector at STAR
    Brandenburg, James D.
    Adam, J.
    Adamczyk, L.
    Adams, J. R.
    Adkins, J. K.
    Agakishiev, G.
    Aggarwal, M. M.
    Ahammed, Z.
    Alekseev, I.
    Anderson, D. M.
    Aoyama, R.
    Aparin, A.
    Arkhipkin, D.
    Aschenauer, E. C.
    Ashraf, M. U.
    Atetalla, F.
    Attri, A.
    Averichev, G. S.
    Bai, X.
    Bairathi, V.
    Barish, K.
    Bassill, A. J.
    Behera, A.
    Beliwied, R.
    Bhasin, A.
    Bhati, A. K.
    Bielcik, J.
    Bielcikova, J.
    Bland, L. C.
    Bordyuzhin, I. G.
    Brandenburg, J. D.
    Brandin, A. V.
    Brown, D.
    Bryslawskyj, J.
    Bunzarov, I.
    Butterworth, J.
    Caines, H.
    Sanchez, M. Calderon De la Barca
    Cebra, D.
    Chakaberia, I.
    Chaloupka, P.
    Chan, B. K.
    Chang, F-H.
    Chang, Z.
    Chankova-Bunzarova, N.
    Chatterjee, A.
    Chattopadhyay, S.
    Chen, J. H.
    Chen, X.
    Chen, X.
    NUCLEAR PHYSICS A, 2019, 982 : 192 - 194
  • [2] Muon identification with Muon Telescope Detector at the STAR experiment
    Huang, T. C.
    Ma, R.
    Huang, B.
    Huang, X.
    Ruan, L.
    Todoroki, T.
    Xu, Z.
    Yang, C.
    Yang, S.
    Yang, Q.
    Yang, Y.
    Zha, W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 833 : 88 - 93
  • [3] MEASUREMENTS OF THE COSMIC MUON FLUX WITH THE WILLI DETECTOR AS A SOURCE OF INFORMATION ABOUT SOLAR EVENTS
    Saftoiu, A.
    Bercuci, A.
    Brancus, I. M.
    Duma, M.
    Haungs, A.
    Mitrica, B.
    Petcu, M.
    Rebel, H.
    Sima, O.
    Toma, G.
    ROMANIAN JOURNAL OF PHYSICS, 2011, 56 (5-6): : 664 - 672
  • [4] FEPE calibration of a HPGe detector using radioactive sphere source
    Abbas, Mahmoud I.
    CONFERENCE ON THE APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY (CAARI 2016), 2017, 90 : 364 - 368
  • [5] Muon identification and triggering with the ATLAS detector
    Barberio, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 408 (01): : 283 - 288
  • [6] TUBERCULOSIS SURVEY SYSTEM USING PORTABLE RADIOACTIVE SOURCE FOR CHEST RADIOGRAPHY
    GREEN, FL
    KRABBENHOFT, KL
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1964, 7 (01): : 206 - &
  • [7] Middle-Atmosphere Dynamics Observed With a Portable Muon Detector
    Tramontini, M.
    Rosas-Carbajal, M.
    Nussbaum, C.
    Gibert, D.
    Marteau, J.
    EARTH AND SPACE SCIENCE, 2019, 6 (10) : 1865 - 1876
  • [8] PION MUON IDENTIFICATION IN THE ALEPH DETECTOR USING THE DISCRIMINANT ANALYSIS.
    Capon, G.
    Nuclear instruments and methods in physics research, 1986, A263 (01): : 58 - 65
  • [9] PION MUON IDENTIFICATION IN THE ALEPH DETECTOR USING THE DISCRIMINANT-ANALYSIS
    CAPON, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (01): : 58 - 65
  • [10] Muon density measurements with the KASCADE central detector
    Antoni, T
    Apel, WD
    Badea, F
    Bekk, K
    Bernlöhr, K
    Blümer, H
    Bollmann, E
    Bozdog, H
    Brancus, IM
    Büttner, C
    Chilingarian, A
    Daumiller, K
    Doll, P
    Engler, J
    Fessler, F
    Gils, HJ
    Glasstetter, R
    Haeusler, R
    Haungs, A
    Heck, D
    Holst, T
    Hörandel, JR
    Kampert, KH
    Kempa, J
    Klages, HO
    Knapp, J
    Köhler, KU
    Maier, G
    Mathes, HJ
    Mayer, HJ
    Milke, J
    Müller, M
    Oehlschläger, J
    Petcu, M
    Rebel, H
    Risse, M
    Roth, M
    Schatz, G
    Scholz, J
    Sokhoyan, SH
    Thouw, T
    Ulrich, H
    Vulpescu, B
    Weber, JH
    Wentz, J
    Wochele, J
    Zabierowski, J
    Zagromski, S
    ASTROPARTICLE PHYSICS, 2002, 16 (04) : 373 - 386