Using a portable muon detector for radioactive source measurements and identification

被引:1
|
作者
Masias, J. [1 ]
Delgado, F. [1 ]
Coll, L. [1 ]
Perez, A. [1 ]
Bazo, J. [1 ]
Gago, A. M. [1 ]
机构
[1] Pontificia Univ Catolica Peru, Secc Fis, Dept Ciencias, Av Univ 1801, Lima 32, Peru
关键词
Muon detector; Plastic scintillator; Geant4; Beta sources;
D O I
10.1016/j.nima.2019.162588
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have re-purposed portable plastic scintillator muon detectors, designed by the CosmicWatch project, for the measurement of electrons emitted by the decay of radioactive sources. For the latter purpose we have first calibrated the detectors using the local atmospheric muon flux, performing angular distribution and attenuation measurements. In addition, we have simulated the detector using Geant4 in a detailed fashion for a cross-check and better understanding of the device. Then, we have developed a method to evaluate the activity of beta-sources and to discriminate different beta-sources by looking into their respective voltage spectrum output.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] 3D cosmic-ray muon tomography using portable muography detector
    Chaiwongkhot, K.
    Kin, T.
    Nagata, Y.
    Komori, T.
    Okamoto, N.
    Basiri, H.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (01)
  • [12] Optimising a muon spectrometer for measurements at the ISIS pulsed muon source
    Giblin, S. R.
    Cottrell, S. P.
    King, P. J. C.
    Tomlinson, S.
    Jago, S. J. S.
    Randall, L. J.
    Roberts, M. J.
    Norris, J.
    Howarth, S.
    Mutamba, Q. B.
    Rhodes, N. J.
    Akeroyd, F. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 751 : 70 - 78
  • [13] Muon identification and reconstruction in the ATLAS detector at the LHC
    Tarem, S
    Panikashvili, N
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2186 - 2190
  • [14] Performance of the muon identification and reconstruction with the ATLAS detector
    Leontsinis, Stefanos
    3RD INTERNATIONAL CONFERENCE ON NEW FRONTIERS IN PHYSICS, 2015, 95
  • [15] Portable source identification device
    Andersen, ES
    Samuel, TJ
    Gervais, KL
    Nondestructive Detection and Measurement for Homeland Security III, 2005, 5769 : 41 - 47
  • [16] CosmoLink: portable coincidence detector for on-site muon flux measurement
    Elangovan, Yuvaraj
    JOURNAL OF INSTRUMENTATION, 2025, 20 (03):
  • [17] Characterization of a silicon microstrip detector with radioactive source
    Alpat, B
    Esposito, G
    INSTRUMENTATION IN ELEMENTARY PARTICLE PHYSICS, 2003, 674 : 283 - 295
  • [18] Radioactive source localization by a two detector system
    Papadimitropoulos, C.
    Kaissas, I.
    Potiriadis, C.
    Karafasoulis, K.
    Loukas, D.
    Lambropoulos, C. P.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [19] MEASUREMENTS OF THE MUON-FLUX WITH THE FREJUS-DETECTOR
    RHODE, W
    NUCLEAR PHYSICS B, 1994, : 250 - 253
  • [20] Man-portable Radiation Detector based on Advanced Source Detection, Identification, and Localization Algorithms
    Shokhirev, Kirill N.
    Konno, Daisei
    Schmit, Thomas M.
    Ziskin, Vitaliy
    Cosofret, Bogdan R.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,