The COCAE Detector: An instrument for localization - identification of radioactive sources

被引:0
|
作者
Lambropoulos, C. P. [1 ]
Aoki, T.
Crocco, J. [2 ]
Dieguez, E. [2 ]
Disch, C. [3 ]
Fauler, A. [3 ]
Fiederle, M. [3 ]
Hatzistratis, D. [1 ,4 ,9 ]
Gnatyuk, V. A.
Karafasoulis, K. [5 ]
Kosyachenko, L. A. [6 ]
Levytskyi, S. N. [7 ]
Loukas, D. [8 ]
Maslyanchuk, O. L. [6 ]
Medvids, A. [10 ]
Orphanoudakis, T. [1 ]
Papadakis, I. [9 ]
Papadimitriou, A. [9 ]
Papakonstantinou, K. [1 ,9 ]
Potiriadis, C.
Schulman, T.
Sklyarchuk, V. V. [6 ]
Spartiotis, K.
Theodoratos, G. [1 ,9 ]
Vlasenko, O. I.
Zachariadou, K.
Zervakis, E. [1 ]
机构
[1] Technol Educ Inst Chalkida, Psahna Evia 34400, Greece
[2] Univ Shizuoka, Dept Fis Mat, Shizuoka 4228526, Japan
[3] Univ Freiburg, Freiburg, Germany
[4] Technol Educ Inst Chalkida, Psahna Evia 34400, Greece
[5] Greek Atom Engy Commiss, Athens, Greece
[6] Univ KwaZulu Natal, Chernovtsy, Ukraine
[7] Natl Acad Sci, Inst Semicond Phys, Kiev, Ukraine
[8] Natl Ctr Scient Res, Athens, Greece
[9] Technol Educ Inst, Psahna Evia 34400, Greece
[10] Riga Tech Univ, Riga, Latvia
关键词
CDZNTE; CDTE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The COCAE project develops an instrument for localization and identification of radioactive sources. For the localization task it will exploit the Compton scattered photons within its detecting layers. It is based on pixilated Cd(Zn)Te matrices in a stacked configuration. Progress has been achieved in all the components necessary for this technology. CdZnTe crystals have been grown of up to 75mm in diameter. A wafer level pixelization process has been tested and its results will be presented. Very good energy resolution is necessary for the performance of the instrument. For this reason we have investigated planar M-p-n diodes fabricated by using laser-induced solid phase doping and Schottky diodes created by Arion etching of the Cd(Zn) Te surfaces before deposition of Ni electrodes. The energy resolution achieved is better than 1% FWHM @662KeV. The development of a pixel CMOS readout integrated circuit has been undertaken. It outputs in digital format address, energy and time information for the pixels which have collected charge above a given threshold. Simulation studies of the minimum detection limits, of the Compton sequencing algorithms, of the angular resolution and of the reconstruction of the radioactive source position have been performed. Experiments with a precursor setup using an existing hybrid detector are underway.
引用
收藏
页码:3910 / 3917
页数:8
相关论文
共 50 条
  • [42] A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector
    Banks, T. I.
    Freedman, S. J.
    Wallig, J.
    Ybarrolaza, N.
    Gando, A.
    Gando, Y.
    Ikeda, H.
    Inoue, K.
    Kishimoto, Y.
    Koga, M.
    Mitsui, T.
    Nakamura, K.
    Shimizu, I.
    Shirai, J.
    Suzuki, A.
    Takemoto, Y.
    Tamae, K.
    Ueshima, K.
    Watanabe, H.
    Xu, B. D.
    Yoshida, H.
    Yoshida, S.
    Kozlov, A.
    Grant, C.
    Keefer, G.
    Piepke, A.
    Bloxham, T.
    Fujikawa, B. K.
    Han, K.
    Ichimura, K.
    Murayama, H.
    O'Donnell, T.
    Steiner, H. M.
    Winslow, L. A.
    Dwyer, D. A.
    McKeown, R. D.
    Zhang, C.
    Berger, B. E.
    Lane, C. E.
    Maricic, J.
    Miletic, T.
    Batygov, M.
    Learned, J. G.
    Matsuno, S.
    Sakai, M.
    Horton-Smith, G. A.
    Downum, K. E.
    Gratta, G.
    Efremenko, Y.
    Perevozchikov, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 769 : 88 - 96
  • [43] Heuristic techniques for maximum likelihood localization of radioactive sources via a sensor network
    Assem Abdelhakim
    Nuclear Science and Techniques, 2023, 34 (08) : 158 - 177
  • [44] Radioactive source localization inside pipes using a long-range alpha detector
    吴雪梅
    庹先国
    李哲
    刘明哲
    张金钊
    董湘龙
    李平川
    Chinese Physics C, 2013, 37 (08) : 56 - 60
  • [45] Radioactive source localization inside pipes using a long-range alpha detector
    Wu Xue-Mei
    Tuo Xian-Guo
    Li Zhe
    Liu Ming-Zhe
    Zhang Jin-Zhao
    Dong Xiang-Long
    Li Ping-Chuan
    CHINESE PHYSICS C, 2013, 37 (08)
  • [46] CALIBRATION OF NaI (Tl) CYLINDRICAL DETECTOR USING AXIALLY SHIFTED RADIOACTIVE CYLINDRICAL SOURCES
    Gouda, Mona M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2019, 34 (04): : 353 - 360
  • [47] Calibration of Cylindrical NaI(Tl) Detector Using Different Perpendicular Radioactive Cylindrical Sources
    Badawi, Mohamed. S.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (04): : 67 - 75
  • [48] Identification and localization of sound sources in the median sagittal plane
    Rakerd, B
    Hartmann, WM
    McCaskey, TL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 106 (05): : 2812 - 2820
  • [49] Identification and topographic localization of metallic foreign bodies by metal detector
    Muensterer, OJ
    Joppich, I
    JOURNAL OF PEDIATRIC SURGERY, 2004, 39 (08) : 1245 - 1248
  • [50] Calibration of a time-resolved hard-x-ray detector using radioactive sources
    Stoeckl, C.
    Theobald, W.
    Regan, S. P.
    Romanofsky, M. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):