The COCAE Detector: An instrument for localization - identification of radioactive sources

被引:0
|
作者
Lambropoulos, C. P. [1 ]
Aoki, T.
Crocco, J. [2 ]
Dieguez, E. [2 ]
Disch, C. [3 ]
Fauler, A. [3 ]
Fiederle, M. [3 ]
Hatzistratis, D. [1 ,4 ,9 ]
Gnatyuk, V. A.
Karafasoulis, K. [5 ]
Kosyachenko, L. A. [6 ]
Levytskyi, S. N. [7 ]
Loukas, D. [8 ]
Maslyanchuk, O. L. [6 ]
Medvids, A. [10 ]
Orphanoudakis, T. [1 ]
Papadakis, I. [9 ]
Papadimitriou, A. [9 ]
Papakonstantinou, K. [1 ,9 ]
Potiriadis, C.
Schulman, T.
Sklyarchuk, V. V. [6 ]
Spartiotis, K.
Theodoratos, G. [1 ,9 ]
Vlasenko, O. I.
Zachariadou, K.
Zervakis, E. [1 ]
机构
[1] Technol Educ Inst Chalkida, Psahna Evia 34400, Greece
[2] Univ Shizuoka, Dept Fis Mat, Shizuoka 4228526, Japan
[3] Univ Freiburg, Freiburg, Germany
[4] Technol Educ Inst Chalkida, Psahna Evia 34400, Greece
[5] Greek Atom Engy Commiss, Athens, Greece
[6] Univ KwaZulu Natal, Chernovtsy, Ukraine
[7] Natl Acad Sci, Inst Semicond Phys, Kiev, Ukraine
[8] Natl Ctr Scient Res, Athens, Greece
[9] Technol Educ Inst, Psahna Evia 34400, Greece
[10] Riga Tech Univ, Riga, Latvia
关键词
CDZNTE; CDTE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The COCAE project develops an instrument for localization and identification of radioactive sources. For the localization task it will exploit the Compton scattered photons within its detecting layers. It is based on pixilated Cd(Zn)Te matrices in a stacked configuration. Progress has been achieved in all the components necessary for this technology. CdZnTe crystals have been grown of up to 75mm in diameter. A wafer level pixelization process has been tested and its results will be presented. Very good energy resolution is necessary for the performance of the instrument. For this reason we have investigated planar M-p-n diodes fabricated by using laser-induced solid phase doping and Schottky diodes created by Arion etching of the Cd(Zn) Te surfaces before deposition of Ni electrodes. The energy resolution achieved is better than 1% FWHM @662KeV. The development of a pixel CMOS readout integrated circuit has been undertaken. It outputs in digital format address, energy and time information for the pixels which have collected charge above a given threshold. Simulation studies of the minimum detection limits, of the Compton sequencing algorithms, of the angular resolution and of the reconstruction of the radioactive source position have been performed. Experiments with a precursor setup using an existing hybrid detector are underway.
引用
收藏
页码:3910 / 3917
页数:8
相关论文
共 50 条
  • [1] The COCAE Detector: An Instrument for Localization-Identification of Radioactive Sources
    Lambropoulos, C. P.
    Aoki, T.
    Crocco, J.
    Dieguez, E.
    Disch, C.
    Fauler, A.
    Fiederle, M.
    Hatzistratis, D.
    Gnatyuk, V. A.
    Karafasoulis, K.
    Kosyachenko, L. A.
    Levytskyi, S. N.
    Loukas, D.
    Maslyanchuk, O. L.
    Medvids, A.
    Orphanoudakis, T.
    Papadakis, I.
    Papadimitriou, A.
    Papakonstantinou, K.
    Potiriadis, C.
    Schulman, T.
    Sklyarchuk, V. V.
    Spartiotis, K.
    Theodoratos, G.
    Vlasenko, O. I.
    Zachariadou, K.
    Zervakis, E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2363 - 2370
  • [2] Simulated Performance of Algorithms for the Localization of Radioactive Sources from a Position Sensitive Radiation Detecting System (COCAE)
    Karafasoulis, K.
    Zachariadou, K.
    Seferlis, S.
    Kaissas, I.
    Lambropoulos, C.
    Loukas, D.
    Potiriadis, C.
    APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [3] Implementation of an Imaging Spectrometer for Localization and Identification of Radioactive Sources
    Lemaire, Hermine
    Amgarou, Khalil
    Abou Khalil, Roger
    Angelique, Jean-Claude
    Bonnet, Florent
    De Toro, Daniel
    Carrel, Frederick
    Giarmana, Olivier
    Gmar, Mehdi
    Menaa, Nabil
    Menesguen, Yves
    Normand, Stephane
    Patoz, Audrey
    Schoepff, Vincent
    Talent, Philippe
    Timi, Tebug
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [4] Implementation of an imaging spectrometer for localization and identification of radioactive sources
    Lemaire, H.
    Abou Khalil, R.
    Amgarou, K.
    Angelique, J. -C
    Bonnet, F.
    De Toro, D.
    Carrel, F.
    Giarmana, O.
    Gmar, M.
    Menaa, N.
    Menesguen, Y.
    Normand, S.
    Patoz, A.
    Schoepff, V.
    Talent, P.
    Timi, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 : 97 - 103
  • [5] Calibration of a DSSSD detector with radioactive sources
    Guadilla, V.
    Tain, J. L.
    Agramunt, J.
    Algora, A.
    Domingo-Pardo, C.
    Rubio, B.
    LA RABIDA 2012 INTERNATIONAL SCIENTIFIC MEETING ON NUCLEAR PHYSICS: BASIC CONCEPTS IN NUCLEAR PHYSICS: THEORY, EXPERIMENTS, AND APPLICATIONS, 2013, 1541 : 173 - 174
  • [6] Localization of two radioactive sources on the plane
    O. V. Chernoyarov
    S. Dachian
    C. Farinetto
    Yu. A. Kutoyants
    Statistical Inference for Stochastic Processes, 2024, 27 : 1 - 23
  • [7] On the Gradient Descent Localization of Radioactive Sources
    Baidoo-Williams, Henry E.
    Dasgupta, Soura
    Mudumbai, Raghuraman
    Bai, Erwei
    IEEE SIGNAL PROCESSING LETTERS, 2013, 20 (11) : 1046 - 1049
  • [8] Localization of two radioactive sources on the plane
    Chernoyarov, O. V.
    Dachian, S.
    Farinetto, C.
    Kutoyants, Yu. A.
    STATISTICAL INFERENCE FOR STOCHASTIC PROCESSES, 2024, 27 (01) : 1 - 23
  • [9] SCINTILLATION DETECTOR FOR THE LOCALIZATION OF RADIOACTIVE CONCENTRATIONS INVIVO
    ITTNER, WB
    TERPOGOSSIAN, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1951, 22 (08): : 638 - 641
  • [10] Radioactive source localization by a two detector system
    Papadimitropoulos, C.
    Kaissas, I.
    Potiriadis, C.
    Karafasoulis, K.
    Loukas, D.
    Lambropoulos, C. P.
    JOURNAL OF INSTRUMENTATION, 2015, 10