Dosimetric comparison of 3-dimensional conformal and field-in-field radiotherapy techniques for the adjuvant treatment of early stage endometrial cancer

被引:8
|
作者
Yavas, Guler [1 ]
Yavas, Cagdas [2 ]
Acar, Hilal [1 ]
Buyukyoruk, Ahmet [1 ]
Cobanoglu, Gokcen [1 ]
Kerimoglu, Ozlem Secilmis [3 ]
Yavas, Ozlem [4 ]
Celik, Cetin [3 ]
机构
[1] Selcuk Univ, Fac Med, Dept Radiat Oncol, TR-42075 Konya, Turkey
[2] Konya Training & Res Hosp, Dept Radiat Oncol, Konya, Turkey
[3] Selcuk Univ, Fac Med, Dept Obstet & Gynecol, TR-42075 Konya, Turkey
[4] Selcuk Univ, Fac Med, Dept Med Oncol, TR-42075 Konya, Turkey
来源
关键词
Endometrial cancer; Conformal radiotherapy; Dose-volume histograms; Field-in-field radiotherapy; MODULATED RADIATION-THERAPY; ACUTE HEMATOLOGIC TOXICITY; CERVICAL-CANCER; ADENOCARCINOMA; IRRADIATION; GUIDELINES; PARAMETERS; CARCINOMA; RECTUM; VOLUME;
D O I
10.1016/j.ejmp.2012.11.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The purpose of this study is to compare field-in-field radiotherapy (FIF) with conformal radiotherapy (CRT) in terms of dosimetric benefits for early stage endometrial cancer patients. Materials and methods: Ten consecutive early stage endometrial cancer patients who underwent adjuvant external beam radiotherapy were included in the study. For each patient, two different treatment plans were created. FIF and CRT plans were compared for doses in the planning target volume (PTV), the organ at risk (OAR) volumes including rectum, bladder, bowel, bilateral femurs and bone marrow, the dose homogeneity index, and the monitor unit counts required for the treatment. Results: The FIF technique significantly reduced the maximum dose of the PTV, rectum, bladder, bowel, left femur, right femur and bone marrow (p values were: <0.001, 0.031, 0.003, <0.001, 0.001, 0.001 and <0.001 respectively). When the OAR volumes irradiated with >30 and >45 Gy were compared, the results were in favor of the FIF technique. The volumes of rectum, bladder, bowel, left femur, right femur and bone marrow receiving more than the prescription dose of 45 Gy were significantly reduced with FIF technique (p values were 0.016, 0.039, 0.01, 0.04, 0.037 and 0.01 respectively). The dose homogeneity index (DHI) was significantly improved with FIF technique (p < 0.001). Conclusions: FIF allowed more homogeneous dose distribution in the PTV and reduced the doses received by OAR. Considering the lower maximum doses in the OAR and PTV, FIF technique seems to be more advantageous than CRT during adjuvant radiotherapy for early stage endometrial cancer patients. (C) 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 50 条
  • [31] Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients
    Waheed, Asmara
    Butt, Sumera
    Ishtiaq, Ali
    Mansha, Muhammad Atif
    Mehreen, Sana
    Raza, Mohsin
    Yousaf, Muhammad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [32] Dosimetric comparison of three-dimensional conformal radiotherapy and static and dynamic intensity-modulated radiotherapy for the treatment of early-stage glottic cancer
    Inan, Gokcen
    Gul, Osman Vefa
    JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (3-4) : 165 - 172
  • [33] Comparison of 3-dimensional conformal radiotherapy and intensity modulated radiotherapy for breast cancer
    Kivanc, H.
    Gultekin, M.
    Yildiz, F.
    Gurkaynak, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S189 - S189
  • [34] Dosimetric Comparison Between 3-Dimensional Conformal and Robotic SBRT Treatment Plans for Accelerated Partial Breast Radiotherapy
    Goggin, L. M.
    Descovich, M.
    McGuinness, C.
    Shiao, S.
    Pouliot, J.
    Park, C.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (03) : 437 - 445
  • [35] Dosimetric Comparison of Different Beam Energy in Breast Field-In-Field Forward Treatment Planning
    Tseng, T.
    Tam, J.
    Powers, A.
    Dumane, V.
    Green, S.
    Lo, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2916 - 2916
  • [36] DOSIMETRIC COMPARISON BETWEEN INTENSITY MODULATED RADIOTHERAPY AND 3 DIMENSIONAL CONFORMAL RADIOTHERAPY AS POST-OPERATIVE ADJUVANT TREATMENT IN RETROPERITONEAL SARCOMA
    Negretti, L.
    Paumier, A.
    Ferreira, I. H.
    Beaudre, A.
    Roberti, E.
    Brahim, J.
    Lefkopoulos, D.
    Daly-Schveitzer, N.
    Bourhis, J.
    Bonvalot, S.
    Le Pechoux, C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S380 - S380
  • [37] Verification of Monitor Unit Calculations for Breast Field-In-Field Three-Dimensional Conformal Radiotherapy Plans
    Kosztyla, Robert
    Pierce, Greg
    Ploquin, Nicolas
    Roumeliotis, Michael
    Schinkel, Colleen
    MEDICAL PHYSICS, 2016, 43 (08) : 4940 - 4941
  • [38] DOSE DISTRIBUTION ANALYSIS OF AXILLARY LYMPH NODES FOR THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH A FIELD-IN-FIELD TECHNIQUE FOR BREAST CANCER
    Ohashi, Toshio
    Takeda, Atsuya
    Shigematsu, Naoyuki
    Fukada, Junichi
    Sanuki, Naoko
    Amemiya, Atsushi
    Kubo, Atsushi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01): : 80 - 87
  • [39] Adjuvant radiotherapy for gallbladder cancer: A dosimetric comparison of conformal radiotherapy and intensity-modulated radiotherapy
    Sun, Xiao-Nan
    Wang, Qi
    Gu, Ben-Xing
    Zhu, Yan-Hong
    Hu, Jian-Bin
    Shi, Guo-Zhi
    Zheng, Shu
    WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (03) : 397 - 402