Characterization of 3-Dimensional Printing and Casting Materials for use in Magnetic Resonance Imaging Phantoms at 3 T

被引:6
|
作者
Yunker, B. E. [1 ,2 ]
Stupic, K. F. [1 ]
Wagner, J. L. [2 ]
Huddle, S. [2 ]
Shandas, R. [2 ]
Weir, R. F. [2 ]
Russek, S. E. [1 ]
Keenan, K. E. [1 ]
机构
[1] NIST, Phys Measurement Lab, Boulder, CO 80305 USA
[2] Univ Colorado Denver Anschutz, Aurora, CO 80045 USA
关键词
3D printing; medical imaging; MRI; phantom; polymer; RELAXATION-TIMES; BREAST-TISSUE; IN-VIVO; MRI; T-1; MODELS; SEQUENCES; RESECTION;
D O I
10.6028/jres.125.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging phantoms are used to calibrate and validate the performance of magnetic resonance imaging (MRI) systems. Many new materials have been developed for additive manufacturing (three-dimensional [3D] printing) processes that may be useful in the direct printing or casting of dimensionally accurate, anatomically accurate, patient-specific, and/or biomimetic MRI phantoms. The T-1, T-2, and T-2* spin relaxation times of polymer samples were tested to discover materials for use as tissue mimics and structures in MRI phantoms. This study included a cohort of polymer compounds that was tested in cured form. The cohort consisted of 101 standardized polymer samples fabricated from: two-part silicones and polyurethanes used in commercial casting processes; one-part optically cured polyurethanes used in 3D printing; and fused deposition thermoplastics used in 3D printing. The testing was performed at 3 T using inversion recovery, spin echo, and gradient echo sequences for T-1, T-2, and T-2*, respectively. T-1, T-2, and T-2* values were plotted with error bars to allow the reader to assess how well a polymer matches a tissue for a specific application. A correlation was performed between T-1, T-2, T-2* values and material density, elongation, tensile strength, and hardness. Two silicones, SI_XP-643 and SI_P-45, may be usable mimics for reported liver values; one silicone, SI_XP-643, may be a useful mimic for muscle; one silicone, SI_XP-738, may be a useful mimic for white matter; and four silicones, SI_P-15, SI_GI-1000, SI_GI-1040, and SI_GI-1110, may be usable mimics for spinal cord. Elongation correlated to T-2 (p = 0.0007), tensile strength correlated to T-1 (p = 0.002), T-2 (p = 0.0003), and T-2* (p = 0.003). The 80 samples not providing measurable signal with T-1, T-2, T-2* relaxation values too short to measure with the standard sequences, may be useful for MRI-invisible fixturing and medical devices at 3 T.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] New process and materials developments in 3-Dimensional Printing, 3DP
    Uhland, S.A.
    Holman, R.K.
    Cima, M.J.
    Sachs, E.
    Enokido, Y.
    Materials Research Society Symposium - Proceedings, 542 : 153 - 158
  • [32] Commentary on 3-Dimensional Printing
    Merritt, Jesalyn
    Konda, Sailesh
    DERMATOLOGIC SURGERY, 2020, 46 (12) : 1506 - 1507
  • [33] The Possibilities of 3-Dimensional Printing
    Zuzelo, Patti Rager
    HOLISTIC NURSING PRACTICE, 2019, 33 (04) : 254 - 255
  • [34] 3-DIMENSIONAL FUNCTIONAL MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN ON A CLINICAL 1.5-T SCANNER
    VANGELDEREN, P
    RAMSEY, NF
    LIU, GY
    DUYN, JH
    FRANK, JA
    WEINBERGER, DR
    MOONEN, CTW
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (15) : 6906 - 6910
  • [35] Use of preoperative, 3-dimensional magnetic resonance cholangiopancreatography in pediatric choledochal cysts
    Saito, Takeshi
    Hishiki, Tomoro
    Terui, Keita
    Sato, Yoshiharu
    Mitsunaga, Tetsuya
    Terui, Elena
    Nakata, Mitsuyuki
    Takenouchi, Ayako
    Matsuura, Gen
    Yahata, Eriko
    Ohno, Sachie
    Sato, Hirotaka
    Yanagawa, Noriyuki
    Masuda, Yoshitada
    Yoshida, Hideo
    SURGERY, 2011, 149 (04) : 569 - 575
  • [36] Impact of 3-dimensional imaging and printing on septal myectomy results
    Daungsupawong, Hinpetch
    Wiwanitkit, Viroj
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 39 (06):
  • [37] Accuracy and Consistency of 3-Dimensional Magnetic Resonance Imaging Is Comparable With 3-Dimensional Computed Tomography in Assessing Glenohumeral Instability: A Systematic Review
    Liu, Gaoming
    Huang, Cheng
    Li, Yusheng
    Jiang, Shide
    Lu, Wenhao
    Hassan, Mahamat Hassan Yacoub
    Essien, Anko Elijah
    Pavel, Volotovski
    Xiao, Wenfeng
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2025, 41 (04):
  • [38] Automated 3-Dimensional Magnetic Resonance Imaging Allows for Accurate Evaluation of Glenoid Bone Loss Compared With 3-Dimensional Computed Tomography
    Lansdown, Drew A.
    Cvetanovich, Gregory L.
    Verma, Nikhil N.
    Cole, Brian J.
    Bach, Bernard R.
    Nicholson, Gregory
    Romeo, Anthony
    Dawe, Robert
    Yanke, Adam B.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (03): : 734 - 740
  • [39] 3-DIMENSIONAL IMAGING - USE IN STUDY OF THE LIVER
    FALISE, B
    FRANCONI, JM
    KAWIECKI, W
    LYON CHIRURGICAL, 1991, 87 (06) : 429 - 432
  • [40] ACCURACY OF VOLUME MEASUREMENTS OF COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING PHANTOMS BY 3-DIMENSIONAL RECONSTRUCTION AND PRELIMINARY CLINICAL-APPLICATION
    DISLER, DG
    MARR, DS
    ROSENTHAL, DI
    INVESTIGATIVE RADIOLOGY, 1994, 29 (08) : 739 - 745