Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation

被引:28
|
作者
Moghari, Mehdi H. [1 ,2 ]
Barthur, Ashita [1 ]
Amaral, Maria E. [1 ]
Geva, Tal [1 ,2 ]
Powell, Andrew J. [1 ,2 ]
机构
[1] Boston Childrens Hosp, Dept Cardiol, 300 Longwood Ave, Boston, MA 02115 USA
[2] Harvard Med Sch, Dept Pediat, Boston, MA USA
基金
美国国家卫生研究院;
关键词
free-breathing; whole-heart; 3D cine; ventricular function; respiratory motion correction; self-navigator; EXTRACELLULAR CONTRAST AGENT; K-T BLAST; VENTRICULAR VOLUMES; CORONARY MRA; CARDIAC CINE; PRECESSION; RECONSTRUCTION; VISUALIZATION; ANGIOGRAPHY; GRAPPA;
D O I
10.1002/mrm.27021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging. MethodsIn a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N=17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set. ResultsAll 3D cine SSFP acquisitions were successful and the mean scan time was 5.92.7min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was<6% except for right ventricular end-systolic volume that was 12%. The 3D cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score. ConclusionThe novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 50 条
  • [41] Distortionless, free-breathing, and respiratory resolved 3D diffusion weighted imaging of the abdomen
    Lee, Philip K.
    Zhou, Xuetong
    Wang, Nan
    Syed, Ali B.
    Brunsing, Ryan L.
    Vasanawala, Shreyas S.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 586 - 604
  • [42] Prospective heart tracking for whole-heart magnetic resonance angiography
    Moghari, Mehdi H.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 759 - 765
  • [43] 2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease
    Nussbaumer, Clement
    Bouchardy, Judith
    Blanche, Coralie
    Piccini, Davide
    Pavon, Anna-Giulia
    Monney, Pierre
    Stuber, Matthias
    Schwitter, Jurg
    Rutz, Tobias
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [44] Intra-bin correction and inter-bin compensation of respiratory motion in free-running five-dimensional whole-heart magnetic resonance imaging
    Roy, Christopher W.
    Milani, Bastien
    Yerly, Jerome
    Si-Mohamed, Salim
    Romanin, Ludovica
    Bustin, Aurelien
    Tenisch, Estelle
    Rutz, Tobias
    Prsa, Milan
    Stuber, Matthias
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (01)
  • [45] Free-Breathing 3D Imaging of Right Ventricular Structure and Function Using Respiratory and Cardiac Self-Gated Cine MRI
    Zhu, Yanchun
    Liu, Jing
    Weinsaft, Jonathan
    Spincemaille, Pascal
    Nguyen, Thanh D.
    Prince, Martin R.
    Bao, Shanglian
    Xie, Yaoqin
    Wang, Yi
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [46] 2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease
    Clément Nussbaumer
    Judith Bouchardy
    Coralie Blanche
    Davide Piccini
    Anna-Giulia Pavon
    Pierre Monney
    Matthias Stuber
    Jürg Schwitter
    Tobias Rutz
    Journal of Cardiovascular Magnetic Resonance, 23
  • [47] Respiratory and Cardiac Self-Gated Free-Breathing Cardiac CINE Imaging With Multiecho 3D Hybrid Radial SSFP Acquisition
    Liu, Jing
    Spincemaille, Pascal
    Codella, Noel C. F.
    Nguyen, Thanh D.
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1230 - 1237
  • [48] Z intensity-weighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging
    spincemaille, Pascal
    Liu, Jing
    Thanh Nguyen
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 861 - 868
  • [49] Accuracy of self-navigated free-breathing isotropic 3D whole heart inversion recovery magnetic resonance for detection of myocardial infarction
    Tobias Rutz
    Davide Piccini
    Jerome Chaptinel
    Simone Coppo
    Gabriella Vincenti
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [50] Feasibility study of the multishot gradient-echo planar imaging sequence in non-enhanced and free-breathing whole-heart magnetic resonance coronary angiography
    Yu, A.
    Gao, H.
    Ma, Y.
    Li, J.
    Zhang, H.
    CLINICAL RADIOLOGY, 2024, 79 (04) : e539 - e545