Z intensity-weighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging

被引:27
|
作者
spincemaille, Pascal [1 ]
Liu, Jing [1 ]
Thanh Nguyen [1 ]
Prince, Martin R. [1 ]
Wang, Yi [1 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10022 USA
关键词
3D cardiac CINE imaging; Center of mass; Respiratory self-gating; Motion artifact suppression; CORONARY MR-ANGIOGRAPHY; VENTRICULAR-FUNCTION; RADIAL SSFP; HOLD; RECONSTRUCTION; ACQUISITION; REDUCTION;
D O I
10.1016/j.mri.2011.02.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A free-breathing 3D cine steady-state free precession (SSFP) technique was developed using the z intensity-weighted position (ZIP) which is the center of mass of a projection along the slice direction as a respiratory gating signal. The ZIP signal was continuously acquired using a slice encoded k-space center sampling in every TR. The performance of this gating method was compared with a method using the k-space center signal (KC) and with conventional 2D breath-hold cine SSFP in healthy subjects by measuring image quality and left ventricular function. The preliminary data obtained here demonstrated that the ZIP gating method provided superior respiratory motion artifact suppression when compared to the KC gating and provided left ventricular ejection fractions, and end-diastolic and end-systolic volumes similar to those obtained with the breath-hold 2D cine SSFP acquisition. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:861 / 868
页数:8
相关论文
共 50 条
  • [1] The accuracy and effectiveness of self-gating signals in free-breathing 3D cardiac cine MRI
    Shuo Li
    Yanchun Zhu
    Jie Yang
    Yaoqin Xie
    Song Gao
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [2] Respiratory and Cardiac Self-Gated Free-Breathing Cardiac CINE Imaging With Multiecho 3D Hybrid Radial SSFP Acquisition
    Liu, Jing
    Spincemaille, Pascal
    Codella, Noel C. F.
    Nguyen, Thanh D.
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1230 - 1237
  • [3] Free-Breathing 3D Imaging of Right Ventricular Structure and Function Using Respiratory and Cardiac Self-Gated Cine MRI
    Zhu, Yanchun
    Liu, Jing
    Weinsaft, Jonathan
    Spincemaille, Pascal
    Nguyen, Thanh D.
    Prince, Martin R.
    Bao, Shanglian
    Xie, Yaoqin
    Wang, Yi
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [4] Distortionless, free-breathing, and respiratory resolved 3D diffusion weighted imaging of the abdomen
    Lee, Philip K.
    Zhou, Xuetong
    Wang, Nan
    Syed, Ali B.
    Brunsing, Ryan L.
    Vasanawala, Shreyas S.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 586 - 604
  • [5] Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI
    Larson, AC
    Kellman, P
    Arai, A
    Hirsch, GA
    McVeigh, E
    Li, DB
    Simonetti, OP
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) : 159 - 168
  • [6] Free-Breathing Steady-State Free Precession Cine Cardiac Magnetic Resonance with Respiratory Navigator Gating
    Moghari, Mehdi H.
    Komarlu, Rukmini
    Annese, David
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) : 1555 - 1561
  • [7] Self-Gated Free-Breathing 3D Coronary CINE Imaging with Simultaneous Water and Fat Visualization
    Liu, Jing
    Nguyen, Thanh D.
    Zhu, Yanchun
    Spincemaille, Pascal
    Prince, Martin R.
    Weinsaft, Jonathan W.
    Saloner, David
    Wang, Yi
    PLOS ONE, 2014, 9 (02):
  • [8] Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation
    Moghari, Mehdi H.
    Barthur, Ashita
    Amaral, Maria E.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 181 - 189
  • [9] Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)
    Zhou, Ruixi
    Yang, Yang
    Mathew, Roshin C.
    Mugler, John P., III
    Weller, Daniel S.
    Kramer, Christopher M.
    Ahmed, Abdul Haseeb
    Jacob, Mathews
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 706 - 720
  • [10] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    Li, Shuo
    Wang, Lei
    Zhu, Yan-Chun
    Yang, Jie
    Xie, Yao-Qin
    Fu, Nan
    Wang, Yi
    Gao, Song
    CHINESE PHYSICS B, 2016, 25 (12)