Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation

被引:28
|
作者
Moghari, Mehdi H. [1 ,2 ]
Barthur, Ashita [1 ]
Amaral, Maria E. [1 ]
Geva, Tal [1 ,2 ]
Powell, Andrew J. [1 ,2 ]
机构
[1] Boston Childrens Hosp, Dept Cardiol, 300 Longwood Ave, Boston, MA 02115 USA
[2] Harvard Med Sch, Dept Pediat, Boston, MA USA
基金
美国国家卫生研究院;
关键词
free-breathing; whole-heart; 3D cine; ventricular function; respiratory motion correction; self-navigator; EXTRACELLULAR CONTRAST AGENT; K-T BLAST; VENTRICULAR VOLUMES; CORONARY MRA; CARDIAC CINE; PRECESSION; RECONSTRUCTION; VISUALIZATION; ANGIOGRAPHY; GRAPPA;
D O I
10.1002/mrm.27021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging. MethodsIn a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N=17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set. ResultsAll 3D cine SSFP acquisitions were successful and the mean scan time was 5.92.7min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was<6% except for right ventricular end-systolic volume that was 12%. The 3D cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score. ConclusionThe novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 50 条
  • [21] Highly efficient free-breathing 3D whole-heart imaging in 3-min: single center study in adults with congenital heart disease
    Fotaki, Anastasia
    Pushparajah, Kuberan
    Rush, Christopher
    Munoz, Camila
    Velasco, Carlos
    Neji, Radhouene
    Kunze, Karl P.
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (01)
  • [22] Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution
    Bustin, Aurelien
    Milotta, Giorgia
    Ismail, Tevfik F.
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 988 - 1002
  • [23] Reproducibility of 3D free-breathing magnetic resonance coronary vessel wall imaging
    Desai, MY
    Lai, SH
    Barmet, C
    Weiss, RG
    Stuber, M
    EUROPEAN HEART JOURNAL, 2005, 26 (21) : 2320 - 2324
  • [24] Fast, whole-heart, free-breathing 3D T2 mapping at 3T with application to myocardial edema imaging
    Hsin-Jung Yang
    Jianing Pang
    Behzad Sharif
    Avinash Kali
    Xiaoming Bi
    Ivan Cokic
    Debiao Li
    Rohan Dharmakumar
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [25] Optimization of coronary whole-heart MRA free-breathing technique at 3 Tesla
    Gharib, Ahmed M.
    Abd-Elmoniem, Khaled Z.
    Herzka, Daniel A.
    Ho, Vincent B.
    Locklin, Julie
    Tzatha, Efstathia
    Stuber, Matthias
    Pettigrew, Roderic I.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (08) : 1125 - 1130
  • [26] Non-Rigid Motion Compensation in Free-Breathing Myocardial Perfusion Magnetic Resonance Imaging
    Wollny, G.
    Ledesma-Carbayo, M. J.
    Kellman, P.
    Santos, A.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 465 - +
  • [27] Correcting versus resolving respiratory motion in free-breathing whole-heart MRA: a comparison in patients with thoracic aortic disease
    Stroud, Robert E.
    Piccini, Davide
    Schoepf, U. Joseph
    Heerfordt, John
    Yerly, Jerome
    Di Sopra, Lorenzo
    Rollins, Jonathan D.
    Fischer, Andreas M.
    Suranyi, Pal
    Varga-Szemes, Akos
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01) : 29
  • [28] Correcting versus resolving respiratory motion in free-breathing whole-heart MRA: a comparison in patients with thoracic aortic disease
    Robert E. Stroud
    Davide Piccini
    U. Joseph Schoepf
    John Heerfordt
    Jérôme Yerly
    Lorenzo Di Sopra
    Jonathan D. Rollins
    Andreas M. Fischer
    Pal Suranyi
    Akos Varga-Szemes
    European Radiology Experimental, 3
  • [29] Motion Corrected 3D Whole-Heart Vessel Wall Imaging
    Gastao J Lima da Cruz
    David Atkinson
    Markus Henningsson
    Rene M Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [30] Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Stuber, M
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 476 - 480