Values for Macular Perimetry Using the MP-1 Microperimeter in Normal Subjects

被引:26
|
作者
Shah, Vinay A. [1 ]
Chalam, K. V. [2 ]
机构
[1] Univ Missouri, Kansas City, MO 64110 USA
[2] Univ Florida, Coll Med, Jacksonville, FL USA
关键词
Microperimeter; MP-1; Normative data; Retinal sensitivity; age; SCANNING LASER OPHTHALMOSCOPE; FUNDUS PERIMETRY; RETINAL SENSITIVITY; VISUAL-FIELD; THRESHOLD; EDEMA;
D O I
10.1159/000162111
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To establish values for the fixation pattern and macular sensitivity to light in healthy subjects using the MP-1 microperimeter (Nideck Technologies, Vigonza, Italy). Method: A prospective study of 37 healthy subjects (age: 19-71 years), approved by the institutional review board. Full-threshold microperimetry of the central 12 degrees of the retina (the macula) was performed prospectively, utilizing 16 points with the MP-1. The fixation stability was simultaneously recorded during microperimetry testing. The relationship between the fixation pattern and light sensitivity with age was calculated using linear regression analysis. Results: Microperimetry was performed on 66 eyes. Total mean sensitivity was 18.33 dB (range: 13.0-19 dB). Mean macular sensitivities at 2 degrees, 4 degrees and 6 degrees as measured by the MP-1 were 18.4 +/- 2.0, 18.2 +/- 2.3 and 18.2 +/- 2.1 dB, respectively. The linear regression analysis revealed a 0.019240, 0.0248 and 0.0285 dB per year age-related decline in mean macular sensitivity at 2 degrees, 4 degrees and 6 degrees from the center of the macula, respectively. The total mean fixation stability values within 2 degrees and 4 degrees were 86 and 96%, respectively. The linear regression analysis also revealed a 0.344% and 0.122% per year decline in age-related fixation stability within 2 degrees and 4 degrees, respectively. There were no statistically significant differences between the median retinal sensitivity or fixation stability values for sex or race in the study. Conclusions: The MP-1 may be a reliable tool to measure macular sensitivity. Among normal healthy subjects, there was a linear decline in light sensitivity with increasing age. Copyright (C) 2008 S. Karger AG, Basel
引用
收藏
页码:9 / 13
页数:5
相关论文
共 50 条
  • [41] SIMPLE ANION-EXCHANGE CHROMATOGRAPHY FOR THE DETERMINATION OF ADENINE-NUCLEOTIDES BY USING AG MP-1 RESIN
    HSU, DS
    CHEN, SS
    JOURNAL OF CHROMATOGRAPHY, 1980, 192 (01): : 193 - 198
  • [42] Reduzierte Makulasensitivität in der Mikroperimetrie bei Patienten mit klinisch signifikantem MakulaödemReduced macular sensitivity in patients with clinically significant diabetic macular edema evaluated with Microperimetry MP-1
    B. Weingessel
    S. Richter-Müksch
    S. Sacu
    U. Schmidt-Erfurth
    P. V. Vécsei-Marlovits
    Spektrum der Augenheilkunde, 2008, 22
  • [43] Retinal sensitivity and fixation changes 1 year after triamcinolone acetonide assisted internal limiting membrane peeling for macular hole surgery - a MP-1 microperimetric study
    Ozdemir, Hakan
    Karacorlu, Murat
    Senturk, Fevzi
    Karacorlu, Serra A.
    Uysal, Omer
    ACTA OPHTHALMOLOGICA, 2010, 88 (06) : e222 - e227
  • [44] PURIFICATION OF RAT INTESTINAL CALCIUM-BINDING PROTEIN (CABP) USING AG MP-1 ION-EXCHANGE CHROMATOGRAPHY
    GLEASON, WA
    LANKFORD, GL
    GASTROENTEROLOGY, 1980, 78 (05) : 1173 - 1173
  • [45] OPERATIONAL PARAMETERS OF ANION-EXCHANGE CHROMATOGRAPHY USING AG MP-1 RESIN FOR RAPID ASSAY OF ADENINE-NUCLEOTIDES
    CHEN, SS
    HSU, DS
    JOURNAL OF CHROMATOGRAPHY, 1980, 198 (04): : 500 - 505
  • [46] CLINICAL RHINO-REO-MANOMETRY .1. VALUES IN NORMAL SUBJECTS
    CRIFO, S
    SAPONARA, M
    CITTADINI, S
    DESETA, E
    DASCANIO, GF
    BOLLETTINO DELLA SOCIETA ITALIANA DI BIOLOGIA SPERIMENTALE, 1975, 51 (07): : 420 - 423
  • [47] Plasma β-amyloid1-42 reference values in cognitively normal subjects
    Zecca, Chiara
    Tortelli, Rosanna
    Panza, Francesco
    Arcuti, Simona
    Piccininni, Marco
    Capozzo, Rosa
    Barulli, Maria Rosaria
    Barone, Roberta
    Cardinali, Roberta
    Abbrescia, Daniela
    Seripa, Davide
    Brescia, Vincenzo
    Logroscino, Giancarlo
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2018, 391 : 120 - 126
  • [48] ANION-EXCHANGE CHROMATOGRAPHY OF PROTEINS ON AG MP-1 USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY EQUIPMENT
    AXELSON, JT
    BODLEY, JW
    CHEN, JY
    DUNLOP, PC
    ROSENTHAL, LP
    VISKUP, RW
    WALSETH, TF
    ANALYTICAL BIOCHEMISTRY, 1984, 142 (02) : 373 - 377
  • [49] Repeatability and reproducibility of macular thickness measurements using the OCT 3 system in normal subjects and diabetic patients
    Workman, HL
    Hosking, SL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U928 - U928
  • [50] Normal values for respiratory resistance using forced oscillation in subjects >65 years old
    Guo, YF
    Herrmann, F
    Michel, JP
    Janssens, JP
    EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (04) : 602 - 608