Values for Macular Perimetry Using the MP-1 Microperimeter in Normal Subjects

被引:26
|
作者
Shah, Vinay A. [1 ]
Chalam, K. V. [2 ]
机构
[1] Univ Missouri, Kansas City, MO 64110 USA
[2] Univ Florida, Coll Med, Jacksonville, FL USA
关键词
Microperimeter; MP-1; Normative data; Retinal sensitivity; age; SCANNING LASER OPHTHALMOSCOPE; FUNDUS PERIMETRY; RETINAL SENSITIVITY; VISUAL-FIELD; THRESHOLD; EDEMA;
D O I
10.1159/000162111
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To establish values for the fixation pattern and macular sensitivity to light in healthy subjects using the MP-1 microperimeter (Nideck Technologies, Vigonza, Italy). Method: A prospective study of 37 healthy subjects (age: 19-71 years), approved by the institutional review board. Full-threshold microperimetry of the central 12 degrees of the retina (the macula) was performed prospectively, utilizing 16 points with the MP-1. The fixation stability was simultaneously recorded during microperimetry testing. The relationship between the fixation pattern and light sensitivity with age was calculated using linear regression analysis. Results: Microperimetry was performed on 66 eyes. Total mean sensitivity was 18.33 dB (range: 13.0-19 dB). Mean macular sensitivities at 2 degrees, 4 degrees and 6 degrees as measured by the MP-1 were 18.4 +/- 2.0, 18.2 +/- 2.3 and 18.2 +/- 2.1 dB, respectively. The linear regression analysis revealed a 0.019240, 0.0248 and 0.0285 dB per year age-related decline in mean macular sensitivity at 2 degrees, 4 degrees and 6 degrees from the center of the macula, respectively. The total mean fixation stability values within 2 degrees and 4 degrees were 86 and 96%, respectively. The linear regression analysis also revealed a 0.344% and 0.122% per year decline in age-related fixation stability within 2 degrees and 4 degrees, respectively. There were no statistically significant differences between the median retinal sensitivity or fixation stability values for sex or race in the study. Conclusions: The MP-1 may be a reliable tool to measure macular sensitivity. Among normal healthy subjects, there was a linear decline in light sensitivity with increasing age. Copyright (C) 2008 S. Karger AG, Basel
引用
收藏
页码:9 / 13
页数:5
相关论文
共 50 条
  • [31] MP1 AND MAIA FUNDUS PERIMETRY IN HEALTHY SUBJECTS AND PATIENTS AFFECTED BY RETINAL DYSTROPHIES
    Parodi, Maurizio Battaglia
    Triolo, Giacinto
    Morales, Marco
    Borrelli, Enrico
    Cicinelli, Maria V.
    Cascavilla, Maria L.
    Bandello, Francesco
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (08): : 1662 - 1669
  • [32] Low-Vision Rehabilitation by Means of MP-1 Biofeedback Examination in Patients with Different Macular Diseases: A Pilot Study
    Vingolo, Enzo M.
    Salvatore, Serena
    Cavarretta, Sonia
    APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2009, 34 (02) : 127 - 133
  • [33] Low-Vision Rehabilitation by Means of MP-1 Biofeedback Examination in Patients with Different Macular Diseases: A Pilot Study
    Enzo M. Vingolo
    Serena Salvatore
    Sonia Cavarretta
    Applied Psychophysiology and Biofeedback, 2009, 34 : 127 - 133
  • [34] Quantification of Fixation Stability by Bivariate Contour Ellipse Area (bcea) Using the Mp1 Microperimeter
    Salvatore, S.
    De Marco, U.
    Marenco, M.
    Vingolo, E. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [35] Mesopic Pelli-Robson contrast sensitivity and MP-1 microperimetry in healthy ageing and age-related macular degeneration
    Maynard, Michelle L.
    Zele, Andrew J.
    Feigl, Beatrix
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E772 - E778
  • [36] CHARACTERISTIC FEATURES OF BLIND SPOT SIZE AND LOCATION, WHEN EVALUATED WITH AUTOMATED PERIMETRY - VALUES OBTAINED IN NORMAL SUBJECTS
    SAFRAN, AB
    MERMILLOD, B
    MERMOUD, C
    DEWEISSE, C
    DESANGLES, D
    NEURO-OPHTHALMOLOGY, 1993, 13 (06) : 309 - 315
  • [37] Nitrate removal from saline water using autotrophic denitrification by the bacterium Thiobacillus denitrificans MP-1
    Zhao, Z
    Qiu, W
    Koenig, A
    Fan, X
    Gu, JD
    ENVIRONMENTAL TECHNOLOGY, 2004, 25 (10) : 1201 - 1210
  • [38] THE DIGITAL BLOOD PRESSURE .1. VALUES IN NORMAL SUBJECTS
    WEAVER, JC
    BOHR, DF
    AMERICAN HEART JOURNAL, 1950, 39 (03) : 413 - 422
  • [39] CLINICAL-APPLICATION OF TIME-DEPENDENT PERIMETRY .1. RESULTS IN NORMAL SUBJECTS
    YASUMA, T
    MIYAKAWA, N
    YAMAZAKI, J
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 1986, 30 (03) : 330 - 337
  • [40] MACULAR FUNCTIONAL CHANGES EVALUATED WITH MP-1 MICROPERIMETRY AFTER INTRAVITREAL BEVACIZUMAB FOR SUBFOVEAL MYOPIC CHOROIDAL NEOVASCULARIZATION One-Year Results
    Scupola, Andrea
    Tiberti, Alessandra C.
    Sasso, Paola
    Savastano, Maria C.
    Mastrocola, Alessandra
    Marangoni, Dario
    Minnella, Angelo M.
    Falsini, Benedetto
    Balestrazzi, Emilio
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (05): : 739 - 747