Values for Macular Perimetry Using the MP-1 Microperimeter in Normal Subjects

被引:26
|
作者
Shah, Vinay A. [1 ]
Chalam, K. V. [2 ]
机构
[1] Univ Missouri, Kansas City, MO 64110 USA
[2] Univ Florida, Coll Med, Jacksonville, FL USA
关键词
Microperimeter; MP-1; Normative data; Retinal sensitivity; age; SCANNING LASER OPHTHALMOSCOPE; FUNDUS PERIMETRY; RETINAL SENSITIVITY; VISUAL-FIELD; THRESHOLD; EDEMA;
D O I
10.1159/000162111
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To establish values for the fixation pattern and macular sensitivity to light in healthy subjects using the MP-1 microperimeter (Nideck Technologies, Vigonza, Italy). Method: A prospective study of 37 healthy subjects (age: 19-71 years), approved by the institutional review board. Full-threshold microperimetry of the central 12 degrees of the retina (the macula) was performed prospectively, utilizing 16 points with the MP-1. The fixation stability was simultaneously recorded during microperimetry testing. The relationship between the fixation pattern and light sensitivity with age was calculated using linear regression analysis. Results: Microperimetry was performed on 66 eyes. Total mean sensitivity was 18.33 dB (range: 13.0-19 dB). Mean macular sensitivities at 2 degrees, 4 degrees and 6 degrees as measured by the MP-1 were 18.4 +/- 2.0, 18.2 +/- 2.3 and 18.2 +/- 2.1 dB, respectively. The linear regression analysis revealed a 0.019240, 0.0248 and 0.0285 dB per year age-related decline in mean macular sensitivity at 2 degrees, 4 degrees and 6 degrees from the center of the macula, respectively. The total mean fixation stability values within 2 degrees and 4 degrees were 86 and 96%, respectively. The linear regression analysis also revealed a 0.344% and 0.122% per year decline in age-related fixation stability within 2 degrees and 4 degrees, respectively. There were no statistically significant differences between the median retinal sensitivity or fixation stability values for sex or race in the study. Conclusions: The MP-1 may be a reliable tool to measure macular sensitivity. Among normal healthy subjects, there was a linear decline in light sensitivity with increasing age. Copyright (C) 2008 S. Karger AG, Basel
引用
收藏
页码:9 / 13
页数:5
相关论文
共 50 条
  • [1] Normal Values for Fundus Perimetry with the Microperimeter MP1
    Midena, Edoardo
    Vujosevic, Stela
    Cavarzeran, Fabiano
    OPHTHALMOLOGY, 2010, 117 (08) : 1571 - U135
  • [2] Fixation characteristics of patients with macular degeneration recorded with the MP-1 microperimeter
    Tarita-Nistor, Luminita
    Gonzalez, Esther G.
    Markowitz, Samuel N.
    Steinbach, Martin J.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (01): : 125 - 133
  • [3] Interexaminer and intraexaminer reliability of the microperimeter MP-1
    B Weingessel
    S Sacu
    P V Vécsei-Marlovits
    A Weingessel
    S Richter-Mueksch
    U Schmidt-Erfurth
    Eye, 2009, 23 : 1052 - 1058
  • [4] Interexaminer and intraexaminer reliability of the microperimeter MP-1
    Weingessel, B.
    Sacu, S.
    Vecsei-Marlovits, P. V.
    Weingessel, A.
    Richter-Mueksch, S.
    Schmidt-Erfurth, U.
    EYE, 2009, 23 (05) : 1052 - 1058
  • [5] Normative data for macular perimetry using the MP-3 microperimeter in healthy individuals
    Neto, Taurino dos Santos Rodrigues
    Neto, Epitacio Dias da Silva
    Higashi, Alex Haruo
    Megnis, Bianca Partezani
    Haddad, Maria Aparecida Onuki
    Monteiro, Mario Luiz Ribeiro
    Zacharias, Leandro Cabral
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (05)
  • [6] Normal values for fundus perimetry using liquid crystal display microperimeter
    Shah, VA
    Lin, SJ
    Shah, GY
    Chalam, KV
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] Fixation behavior in advanced stage glaucoma assessed by the MicroPerimeter MP-1
    Kameda, Takanori
    Tanabe, Teruyo
    Hangai, Masanori
    Ojima, Tomonari
    Aikawa, Hiroko
    Yoshimura, Nagahisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (06) : 580 - 587
  • [8] Fixation behavior in advanced stage glaucoma assessed by the MicroPerimeter MP-1
    Takanori Kameda
    Teruyo Tanabe
    Masanori Hangai
    Tomonari Ojima
    Hiroko Aikawa
    Nagahisa Yoshimura
    Japanese Journal of Ophthalmology, 2009, 53 : 580 - 587
  • [9] Characteristics of Fixation in Patients with Geographic Atrophy Recorded with the MP-1 Microperimeter
    Kroisamer, J. S.
    Sayegh, R.
    Simader, C.
    Scheschy, U.
    Kiss, C.
    Pruente, C.
    Schmidt-Erfurth, U.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [10] Effectiveness of vision rehabilitation treatment through MP-1 microperimeter in patients with visual loss due to macular disease
    Pacella, E.
    Pacella, F.
    Mazzeo, F.
    Turchetti, P.
    Carlesimo, S. C.
    Cerutti, F.
    Lenzi, T.
    De Paolis, G.
    Giorgi, D.
    CLINICA TERAPEUTICA, 2012, 163 (06): : E423 - E428