Model-based detection of hydrogen leaks in a fuel cell stack

被引:38
|
作者
Ingimundarson, Ari [1 ]
Stefanopoulou, Anna G. [2 ]
McKay, Denise A. [2 ]
机构
[1] Tech Univ Catalonia, Dept Automat Control, Terrassa 08222, Spain
[2] Univ Michigan, Fuel Cell Control Lab, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
fault diagnosis; fuel cells; hydrogen leak; safety;
D O I
10.1109/TCST.2007.916311
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Hydrogen leaks are potentially dangerous faults in fuel cell systems that are fed with hydrogen-rich gas mixtures. This brief presents an approach to hydrogen leak detection and, thus, complements direct detection using hydrogen sensors. It relies on simple mass balance equations of an anode filling volume after taking into account the natural leak of the stack. A hydrogen mass flow, anode pressure, and relative humidity sensor are employed. Hydrogen leak detection without the use of relative humidity sensors is considered by employing adaptive alarm thresholds to eliminate false alarms. The validity of the method is also discussed in terms of common hydrogen supply system configurations. The detection method is validated using a 1.25-kW polymer electrolyte membrane fuel cell stack in a laboratory facility where leaks could be introduced in a controlled manner.
引用
收藏
页码:1004 / 1012
页数:9
相关论文
共 50 条
  • [1] Model based detection of hydrogen leaks in a fuel cell stack
    Ingimundarson, Ari
    Stefanopoulou, Anna G.
    McKay, Denise
    [J]. 2005 44th IEEE Conference on Decision and Control & European Control Conference, Vols 1-8, 2005, : 1017 - 1022
  • [2] On-line model-based fault detection and isolation for PEM fuel cell stack systems
    Rosich, A.
    Sarrate, R.
    Nejjari, F.
    [J]. APPLIED MATHEMATICAL MODELLING, 2014, 38 (11-12) : 2744 - 2757
  • [3] Model-based Control Strategy Research for the Hydrogen System of Fuel Cell
    Li, Cheng
    Li, Xiaowei
    Jiang, Weihai
    [J]. IFAC PAPERSONLINE, 2021, 54 (10): : 67 - 71
  • [4] Reduced Order Inferential Model-Based Optimization of a Phosphoric Acid Fuel Cell (PAFC) Stack
    Ganguly, Saibal
    Das, Sonali
    Kargupta, Kajari
    Banerjee, Dipali
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (22) : 7104 - 7115
  • [5] 200W PEM Fuel Cell Stack with Online Model-Based Monitoring System
    Khanungkhid, Pittaya
    Piumsomboon, Pornpote
    [J]. ENGINEERING JOURNAL-THAILAND, 2014, 18 (04): : 13 - 26
  • [6] Model-based fuel pressure regulation algorithm for a hydrogen-injected PEM fuel cell engine
    Fang, Chuan
    Li, Jianqiu
    Xu, Liangfei
    Ouyang, Minggao
    Hu, Junming
    Cheng, Siliang
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (43) : 14942 - 14951
  • [7] Optimized model-based diagnosis approach for hydrogen leakage in hydrogen supply system of fuel cell truck
    Liu, Shu
    He, Ren
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (12) : 17720 - 17725
  • [8] Optimization of a fuel cell stack fueled by hydrogen-based mixtures
    Grigor'ev, S. A.
    Fateev, V. N.
    Sister, V. G.
    Rusanov, V. D.
    [J]. DOKLADY PHYSICAL CHEMISTRY, 2006, 411 (1) : 293 - 296
  • [9] Optimization of a fuel cell stack fueled by hydrogen-based mixtures
    S. A. Grigor’ev
    V. N. Fateev
    V. G. Sister
    V. D. Rusanov
    [J]. Doklady Physical Chemistry, 2006, 411 : 293 - 296
  • [10] Mechanism model-based and data-driven approach for the diagnosis of solid oxide fuel cell stack leakage
    Xu, Yuan-wu
    Wu, Xiao-long
    Zhong, Xiao-bo
    Zhao, Dong-qi
    Sorrentino, Marco
    Jiang, Jianhua
    Jiang, Chang
    Fu, Xiaowei
    Li, Xi
    [J]. APPLIED ENERGY, 2021, 286