Mechanism model-based and data-driven approach for the diagnosis of solid oxide fuel cell stack leakage

被引:23
|
作者
Xu, Yuan-wu [1 ]
Wu, Xiao-long [2 ]
Zhong, Xiao-bo [1 ]
Zhao, Dong-qi [1 ]
Sorrentino, Marco [3 ]
Jiang, Jianhua [1 ]
Jiang, Chang [4 ]
Fu, Xiaowei [5 ]
Li, Xi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Artificial Intelligence & Automat, Key Lab Imaging Proc & Intelligent Control, Wuhan 430074, Hubei, Peoples R China
[2] Nanchang Univ, Sch Informat Engn, Nanchang 330031, Jiangxi, Peoples R China
[3] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
[4] Wuhan Intelligent Equipment Ind Inst, Wuhan 430075, Hubei, Peoples R China
[5] Wuhan Univ Sci & Technol, Coll Comp Sci & Technol, Hubei Prov Key Lab Intelligent Informat Proc & Re, Wuhan 430081, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Solid oxide fuel cell (SOFC); Fault diagnosis; Gas leakages; Model-based; Data-driven; FAULT-DIAGNOSIS; TEMPERATURE DISTRIBUTION; SOFC SYSTEM; METHODOLOGY; STATE; PERFORMANCE; VALIDATION; PREDICTION; OBSERVER; CIRCUIT;
D O I
10.1016/j.apenergy.2021.116508
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Safety and reliability are key objectives for the efficient operation of solid oxide fuel cell (SOFC) power generation systems. Out of many possible faults, the gas leakage of SOFC stack remains a critical issue that leading to efficiency reduction or even degradation. Therefore, the real-time monitoring and diagnosis of gas leakage in the power generation systems are not only an important premise to improve the efficiency, but also can develop the corresponding fault-tolerant strategy for ensuring the system performance. Motivated by this fact, an on-line fault diagnosis scheme based on mechanism model and data-driven method is proposed to monitor and diagnose the gas leakage of the stack. Firstly, the two-state mechanism model of the SOFC stack is established, which can effectively describe the temperature of the fuel layer and air layer. Then, easily-measured stack inputs and outputs are selected, and a novel gas leakage state estimator combined with unscented Kalman filter (UFK) is developed to reconstruct the leakage state. Furthermore, an adaptive thresholds generator is designed to enhance the robustness of the diagnostic scheme. The performance of the fault diagnosis scheme under different leakage scenarios is evaluated, and the simulation results demonstrate the effectiveness of the proposed scheme. The sudden stack fuel leakage failure that occurred in the stable power generation experiment further illustrates the practicability of the scheme. The proposed fault diagnosis scheme has good practicability and can guide the next step compensates for leakage.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A hybrid paradigm combining model-based and data-driven methods for fuel cell stack cooling control
    Sun, Li
    Li, Guanru
    Hua, Q. S.
    Jin, Yuhui
    [J]. RENEWABLE ENERGY, 2020, 147 : 1642 - 1652
  • [2] A Data-Driven Fault Diagnosis Method for Solid Oxide Fuel Cell Systems
    Li, Mingfei
    Chen, Zhengpeng
    Dong, Jiangbo
    Xiong, Kai
    Chen, Chuangting
    Rao, Mumin
    Peng, Zhiping
    Li, Xi
    Peng, Jingxuan
    [J]. ENERGIES, 2022, 15 (07)
  • [3] Adaptive data-driven controller based on fractional calculus for solid oxide fuel cell
    Halledj, Salah Eddine
    Bouafassa, Amar
    Rehahla, Chouaib Dhia Eddine
    Mami, Abderraouf
    [J]. INTERNATIONAL JOURNAL OF DYNAMICS AND CONTROL, 2024, 12 (10) : 3828 - 3844
  • [4] Data-driven nonlinear control of a solid oxide fuel cell system
    Yi-guo Li
    Jiong Shen
    K. Y. Lee
    Xi-chui Liu
    Wen-zhe Fei
    [J]. Journal of Central South University, 2012, 19 : 1892 - 1901
  • [5] Data-driven nonlinear control of a solid oxide fuel cell system
    Li Yi-guo
    Shen Jiong
    Lee, K. Y.
    Liu Xi-chui
    Fei Wen-zhe
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (07) : 1892 - 1901
  • [6] A versatile computational tool for model-based design, control and diagnosis of a generic Solid Oxide Fuel Cell Integrated Stack Module
    Gallo, Marco
    Marra, Dario
    Sorrentino, Marco
    Pianese, Cesare
    Au, Siu Fai
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 171 : 1514 - 1528
  • [7] Data-driven nonlinear control of a solid oxide fuel cell system
    李益国
    沈炯
    K.Y.Lee
    刘西陲
    费文哲
    [J]. Journal of Central South University, 2012, 19 (07) : 1892 - 1901
  • [8] Model-Based Data Normalization for Data-Driven PMSM Fault Diagnosis
    Chen, Zhichao
    Liang, Deliang
    Jia, Shaofeng
    Yang, Shuzhou
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (09) : 11596 - 11612
  • [9] Application of model-based and data-driven techniques in fault diagnosis
    Wang Ziling
    Xu Aiqiang
    Yang Zhiyong
    [J]. ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 451 - +
  • [10] Data-driven Design for Static Model-based Fault Diagnosis
    He, Zhangming
    Wang, Jiongqi
    Yin, Chen
    Zhou, Haiyin
    Wang, Dayi
    Xing, Yan
    [J]. 2015 CHINESE AUTOMATION CONGRESS (CAC), 2015, : 1989 - 1994