Mechanism model-based and data-driven approach for the diagnosis of solid oxide fuel cell stack leakage

被引:23
|
作者
Xu, Yuan-wu [1 ]
Wu, Xiao-long [2 ]
Zhong, Xiao-bo [1 ]
Zhao, Dong-qi [1 ]
Sorrentino, Marco [3 ]
Jiang, Jianhua [1 ]
Jiang, Chang [4 ]
Fu, Xiaowei [5 ]
Li, Xi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Artificial Intelligence & Automat, Key Lab Imaging Proc & Intelligent Control, Wuhan 430074, Hubei, Peoples R China
[2] Nanchang Univ, Sch Informat Engn, Nanchang 330031, Jiangxi, Peoples R China
[3] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
[4] Wuhan Intelligent Equipment Ind Inst, Wuhan 430075, Hubei, Peoples R China
[5] Wuhan Univ Sci & Technol, Coll Comp Sci & Technol, Hubei Prov Key Lab Intelligent Informat Proc & Re, Wuhan 430081, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Solid oxide fuel cell (SOFC); Fault diagnosis; Gas leakages; Model-based; Data-driven; FAULT-DIAGNOSIS; TEMPERATURE DISTRIBUTION; SOFC SYSTEM; METHODOLOGY; STATE; PERFORMANCE; VALIDATION; PREDICTION; OBSERVER; CIRCUIT;
D O I
10.1016/j.apenergy.2021.116508
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Safety and reliability are key objectives for the efficient operation of solid oxide fuel cell (SOFC) power generation systems. Out of many possible faults, the gas leakage of SOFC stack remains a critical issue that leading to efficiency reduction or even degradation. Therefore, the real-time monitoring and diagnosis of gas leakage in the power generation systems are not only an important premise to improve the efficiency, but also can develop the corresponding fault-tolerant strategy for ensuring the system performance. Motivated by this fact, an on-line fault diagnosis scheme based on mechanism model and data-driven method is proposed to monitor and diagnose the gas leakage of the stack. Firstly, the two-state mechanism model of the SOFC stack is established, which can effectively describe the temperature of the fuel layer and air layer. Then, easily-measured stack inputs and outputs are selected, and a novel gas leakage state estimator combined with unscented Kalman filter (UFK) is developed to reconstruct the leakage state. Furthermore, an adaptive thresholds generator is designed to enhance the robustness of the diagnostic scheme. The performance of the fault diagnosis scheme under different leakage scenarios is evaluated, and the simulation results demonstrate the effectiveness of the proposed scheme. The sudden stack fuel leakage failure that occurred in the stable power generation experiment further illustrates the practicability of the scheme. The proposed fault diagnosis scheme has good practicability and can guide the next step compensates for leakage.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Model-based detection of hydrogen leaks in a fuel cell stack
    Ingimundarson, Ari
    Stefanopoulou, Anna G.
    McKay, Denise A.
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2008, 16 (05) : 1004 - 1012
  • [42] A model-based approach for current voltage analyses to quantify degradation and fuel distribution in solid oxide fuel cell stacks
    Linder, Markus
    Hocker, Thomas
    Meier, Christoph
    Holzer, Lorenz
    Friedrich, K. Andreas
    Iwanschitz, Boris
    Mai, Andreas
    Schuler, J. Andreas
    [J]. JOURNAL OF POWER SOURCES, 2015, 288 : 409 - 418
  • [43] Data-driven diagnosis of PEM fuel cell: A comparative study
    Li, Zhongliang
    Outbib, Rachid
    Hissel, Daniel
    Giurgea, Stefan
    [J]. CONTROL ENGINEERING PRACTICE, 2014, 28 : 1 - 12
  • [44] A novel data-driven controller for solid oxide fuel cell via deep reinforcement learning
    Li, Jiawen
    Yu, Tao
    [J]. JOURNAL OF CLEANER PRODUCTION, 2021, 321
  • [45] Integrated Model-based and Data-driven Fault Detection and Diagnosis Approach for an Automotive Electric Power Steering System
    Ghimire, Rajeev
    Sankavaram, Chaitanya
    Ghahari, Alireza
    Pattipati, Krishna
    Ghoneim, Youssef
    Howell, Mark
    Salman, Mutasim
    [J]. IEEE AUTOTESTCON 2011: SYSTEMS READINESS TECHNOLOGY CONFERENCE, 2011, : 70 - 77
  • [46] Data-driven fault diagnosis method for the safe and stable operation of solid oxide fuel cells system
    Zheng, Yi
    Wu, Xiao-long
    Zhao, Dongqi
    Xu, Yuan-wu
    Wang, Beibei
    Zu, Yanmin
    Li, Dong
    Jiang, Jianhua
    Jiang, Chang
    Fu, Xiaowei
    Li, Xi
    [J]. JOURNAL OF POWER SOURCES, 2021, 490
  • [47] Data-driven simultaneous fault diagnosis for solid oxide fuel cell system using multi-label pattern identification
    Li, Shuanghong
    Cao, Hongliang
    Yang, Yupu
    [J]. JOURNAL OF POWER SOURCES, 2018, 378 : 646 - 659
  • [48] A comparison of model-based and data-driven controller tuning
    Formentin, Simone
    van Heusden, Klaske
    Karimi, Alireza
    [J]. INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2014, 28 (10) : 882 - 897
  • [49] Energy Management Strategy of Fuel Cell Electric Vehicles Using Model-Based Reinforcement Learning With Data-Driven Model Update
    Lee, Heeyun
    Cha, Suk Won
    [J]. IEEE ACCESS, 2021, 9 : 59244 - 59254
  • [50] Prognostics and Health Management for Complex system Based on Fusion of Model-based approach and Data-driven approach
    Wang Hong-feng
    [J]. 2010 INTERNATIONAL CONFERENCE ON COMMUNICATION AND VEHICULAR TECHNOLOGY (ICCVT 2010), VOL II, 2010, : 229 - 231